= Core/basic binary (C/C++) API introduction =
= Core/basic binary (C/C++) API introduction =


This API is part of the Advacam's [[Pixet SDK]] and allows access to the Pixet Core functions.<br>
This API is part of the Advacam's [[Pixet SDK]] and allows access to functions of the Pixet Core.<br>
<br>
The binary API parts are:
# '''Binary core/basic API''' (this document)
# [[Binary_Clustering_API|Binary clustering API]]
# [[Binary_Spectral_Imaging_API|Binary spectral imaging API]]
 
'''See:''' [[Pixet SDK|Pixet SDK overview]]
 
== Usage overview ==
* Settings of the device
* Getting information about the device
* Single-frame measurement
* Multi-frame measurement
* Continuous frame measurement (endless repeats and without dead time on some devices, Mpx3 and Tpx2 for example)
* Data-driven (pixel mode) measurement (Tpx3 only)
* Synchronized measurement
* TDI imaging - Scanning linearly moving objects, for example on a conveyor belt.
* Basic image bad pixel correction
* Beam hardening correction (Xray imaging has a very non-linear relationship between the thickness of the material and the intensity of the transmitted radiation. First, low-energy radiation is captured, followed by components that are significantly more penetrating.)
 
== Libraries ==
The core API with the '''pxcore library''', allowing basic measurements and device settings.<br>
The core API with the '''pxcore library''', allowing basic measurements and device settings.<br>
Files:
Files:
Line 16: Line 37:


== Hardware ==
== Hardware ==
This API requires computer with x86 compatible architecture (no ARM), 64bit Windows or Linux and connected some Advacam hardware with imaging chip. Medipix3, Timepix, Timepix2, Timepix3, etc. Some functions are universal for all hardwares (pxcInitialize, pxcGetDeviceName, etc), some is specialized for only one chip type (pxcMeasureSingleFrameTpx3 is Timepix3 only).<br>
This API requires computer with x86 compatible architecture or ARM with memory management features (no small MCU), 64bit Windows or Linux and connected some Advacam hardware with imaging chip. Medipix3, Timepix, Timepix2, Timepix3, etc. Some functions are universal for all hardwares (pxcInitialize, pxcGetDeviceName, etc), some is specialized for only one chip type (pxcMeasureSingleFrameTpx3 is Timepix3 only).<br>
<br>
<br>
'''Specialized functions have names with chip type included:'''
'''Specialized functions have names with chip type included:'''
Line 47: Line 68:


==== Where to get these files? ====
==== Where to get these files? ====
:All need files except  XML configs are located in the zip file with name like us: '''PIXet_SDK_1.8.0_(Build_22b1f335)_Win.zip'''
: All need files except  XML configs are located in the zip file with name like us:
:'''Download:''' [https://downloads.advacam.com/sdk.php Advacam: Pixet Pro Software Updates]<br>
::'''API_PIXet_Pro_1.8.2_Windows_x86_64.zip'''
::'''Download:''' [https://advacam.com/downloads/ Advacam download page]<br>
: Be careful about the correct libraries, we supply
:* Windows-x86-64b
:* Linux-x86-64b
:* Linux-ARM-32b
:* Linux-ARM-64b
<br>
:And all files except LIB files for Windows compilation are located in the Pixet directory:<br>
:And all files except LIB files for Windows compilation are located in the Pixet directory:<br>
[[File:Files-usable-for-SDK-in-Pixet.png|frame|none|alt=All files except LIB files for Windows compilation are located in the Pixet directory|All files except LIB files for Windows compilation are located in the Pixet directory]]
[[File:Files-usable-for-SDK-in-Pixet.png|frame|none|alt=All files except LIB files for Windows compilation are located in the Pixet directory|All files except LIB files for Windows compilation are located in the Pixet directory]]
Line 75: Line 103:
[[File:dirrectory-minimalistic-api-prg.png|frame|center|alt=Example of the minimalistic project dirrectory|Example of the minimalistic project dirrectory]]<br>
[[File:dirrectory-minimalistic-api-prg.png|frame|center|alt=Example of the minimalistic project dirrectory|Example of the minimalistic project dirrectory]]<br>


= Basic examples =
= Some examples =


== Simple C commandline example and build ==
== Simple C commandline example and build ==
Line 152: Line 180:
<syntaxhighlight lang="bash">
<syntaxhighlight lang="bash">
  #!/bin/bash
  #!/bin/bash
  gcc -o build-out minipix1.cpp -Wno-write-strings -L. -lpxcore -lminipix -ldl -lm -lc -g
  gcc -o build-out minipix1.cpp -Wno-write-strings -L. -lpxcore  -ldl -lm -lc -g
</syntaxhighlight>
</syntaxhighlight>


Line 161: Line 189:
  # run last compiled example
  # run last compiled example
</syntaxhighlight>
</syntaxhighlight>
;Troubleshooting:
* Be careful of '''library, platform and system compatibility'''.
: That is, 32/64 bit, Intel vs ARM architecture and the use of unusual Linux distributions.
: Example error message: '''skipping incompatible ./libpxcore.so when searching for -lpxcore'''
* Be careful of '''gcc and it's libraries versions'''.
: If too old, some errors will occur.
: Example error message: '''undefined reference to symbol '_Znam@@GLIBCXX_3.4'''
== C++ Windows CLR examples ==
=== AdvacamAPIexamples package ===
This is the packace of example apps for all device types.
; Link
: https://advacam.com/examples/AdvacamAPIexamples.rar
: (MS Visual Studio 2017 Solution with C++ projects of Windows CLR programs)


== C# examples ==
== C# examples ==
'''Notes:'''
'''Notes:'''
* Use the release/64 bit configuration
* Use the release/64 bit configuration
* Functions that have optional parameters in pxcapi.h (for example pxcInitialize) must be declared with all parameters and then called, for example, with zeros.
* The working directory is directory with the exe file. Typically project\bin\Release. Copy pixet.ini and other auxilliary files here.
* The working directory is directory with the exe file. Typically project\bin\Release. Copy pixet.ini and other auxilliary files here.
* In the MS Visual studio 2019, project first not working. You must click Properties, change .NET version to old, save it, change .NET version back to actual and save. Now project can work.
* In the MS Visual studio 2022 (and may be other), project first not working. You must click Properties, change .NET version to old, save it, change .NET version back to actual and save. Now project can work.
* Our API can also be used to produce cross-platform software. In that case, be careful about the correct libraries, we supply Windows-x86-64b / Linux-x86-64b / Linux-ARM-32b / Linux-ARM-64b.


=== Simple C# commandline example ===
=== Simple C# commandline example ===
Line 188: Line 233:
             Console.WriteLine("pxcInitialize ...");
             Console.WriteLine("pxcInitialize ...");
             rc = pxcInitialize(0, 0);
             rc = pxcInitialize(0, 0);
             Console.WriteLine($"rc={rc:D}");
             Console.WriteLine($"rc={rc:D} (0 is OK)", rc);


             Console.WriteLine("pxcGetDevicesCount...");
             Console.WriteLine("pxcGetDevicesCount...");
Line 202: Line 247:
             Console.WriteLine("pxcExit...");
             Console.WriteLine("pxcExit...");
             rc = pxcExit();
             rc = pxcExit();
             Console.WriteLine("rc={0:D}", rc);
             Console.WriteLine("rc={0:D} (0 is OK)", rc);


             Console.ReadKey();
             Console.ReadKey();
Line 224: Line 269:
=== C# Windows desktop example ===
=== C# Windows desktop example ===


'''See [[C-sharp windows example]]'''
'''See:''' [[C-sharp windows example]]


=== Xojo Basic Windows desktop example ===
== Xojo Basic Windows desktop example ==


'''See [[Xojo windows example]]'''
'''See:''' [[Xojo windows example]]


= API header definition =
= API header definition =
All API functions defined in the pxcapi.h file. Each definition starting with the '''PXCAPI''' keyword:
All API functions are defined in the pxcapi.h file. Each definition starting with the '''PXCAPI''' keyword:
<syntaxhighlight lang="C">
<syntaxhighlight lang="C">
#ifndef WIN32 // Linux
#ifndef WIN32 // Linux
Line 243: Line 288:
This chapter describes auxiliary functions. There are need for normal using of the device, but it not measuring or processing data.
This chapter describes auxiliary functions. There are need for normal using of the device, but it not measuring or processing data.


== Start-up and end ==
== Start-up, end, errors ==


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcInitialize  
| Nam = pxcInitialize  
| HeSym = ===
| HeSym = ===
| Sum = This function initializes the Pixet software and all connected devices. This function has to be called first before any other function except pxcGetLastError.
| Sum = This function initializes the Pixet software and all connected devices. This function has to be called first before any other function except pxcGetLastError. The init process of each device is:
# Initialize hardwrare and communication
# Try to load device XML config file from the "configs" dir
# If failed, try to load device XML config file from the "factory" dir<br>
: Warning: If the correct config is not loaded, the device will not work properly and may do strange things.<br>
'''See'''
: [[Files_and_directories_of_the_Pixet_and_SDK#The_factory_and_the_configs_subdirectories|The factory and the configs subdirectories]]
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = int argc = 0, char const* argv[] = NULL
| DefP = int argc = 0, char const* argv[] = NULL
Line 268: Line 319:
| Nam = pxcExit
| Nam = pxcExit
| HeSym = ===
| HeSym = ===
| Sum = This function deinitializes Pixet software and all the connected devices. This function has to be called as last function before unloading the pxcore library.
| Sum = This function deinitializes Pixet software and all the connected devices. This function has to be called as last function before unloading the pxcore library. The exit process of each device is:
# Save actual device XML config file to the "configs" dir
# Deinitialization of the hardware and communication
'''See'''
: [[Files_and_directories_of_the_Pixet_and_SDK#The_factory_and_the_configs_subdirectories|The factory and the configs subdirectories]]<br>
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP =  
| DefP =  
Line 283: Line 338:
| War =
| War =
| Exa = int rc = pxcExit();
| Exa = int rc = pxcExit();
}}
{{ApiBinaryItem
| Nam = pxcSetDirectories
| HeSym = ===
| Sum = Sets the configuration files directory and directory for log files. Has to be set before calling the pxcInitialize function. Use it to change its default locations defined by pixet.ini.<br>
'''See'''
: [[Files_and_directories_of_the_Pixet_and_SDK#The_factory_and_the_configs_subdirectories|Files and directories of the Pixet and SDK: The factory and the configs subdirectories]]
| DefH = PXCAPI int
| DefP = const char* configsDir, const char* logsDir
| configsDir – Path to the directory for loading/saving config files
| logsDir – Path to the directory for saving log files
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
}}


Line 329: Line 406:
}}
}}


== Parameter Get/Set functions (direct) ==
{{ApiBinaryItem
----
| Nam = pxcGetLastError
Functions described in this chapter working directly, function name defines parameter name and type.<br>
| HeSym = ===
<br>
| Sum = Returns text of last error. This function can be called even before pxcInitialize()
 
| DefH = PXCAPI int
=== Example: Setting operation mode ===
| DefP = char* errorMsgBuffer, unsigned size
----
| errorMsgBuffer - buffer where text will be saved
| size - size of supplied buffer
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa = char msg[200];
pxcGetLastError(msg, 200);<br> printf("Error msg: %s\n", msg);
}}
'''Example1 (console)'''
<br>
<syntaxhighlight lang="C" line>
<syntaxhighlight lang="C" line>
  // Set the operating mode
#define ERRMSG_BUFF_SIZE 512
  rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_TOATOT);
#define ENTER_ON true
printErrors("pxcSetTimepix3Mode", rc);
#define ENTER_OFF false
</syntaxhighlight>
  // (the function used in most examples in this manual)
 
  void printErrors(const char* fName, int rc, bool enter) {
=== Example: List of devices with parameters ===
    char errorMsg[ERRMSG_BUFF_SIZE];
----
    pxcGetLastError(errorMsg, ERRMSG_BUFF_SIZE);
    if (errorMsg[0]>0) {
        printf("%s %d err: %s", fName, rc, errorMsg);
    } else {
        printf("%s %d err: ---", fName, rc);
    }
    if (enter) printf("\n");
}
</syntaxhighlight>
Now you can use it:<br>
<syntaxhighlight lang="C" line>
<syntaxhighlight lang="C" line>
  #include <stdio.h>
  rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_EVENT_ITOT);
#include "pxcapi.h"
printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
#define CHT_Si 0
</syntaxhighlight>
#define CHT_CdTe 1
If mode set was suscessfull, result is:
char chipType = CHT_Unknown;
: '''pxcSetTimepix3Mode 0 err: ---'''
int main(int argc, char const* argv[]) { // #######################################
If not, you can see some as:
    int rc = pxcInitialize();
: '''pxcSetTimepix3Mode -2 err: Invalid device index'''
    if (rc) {
<br>
        printf("Could not initialize Pixet:\n");
'''Example2 (Windows CLR)'''
        printErrors("pxcInitialize", rc, ENTER_ON);
<br>
        return -1;
<syntaxhighlight lang="C" line>
    }
const unsigned cErrBufSize = 512;
    int connectedDevicesCount = pxcGetDevicesCount();
// primary use to show function name, return code, last error message
    printf("Connected devices: %d\n", connectedDevicesCount);
bool errorToList(const char* fName, int rc) {
    if (connectedDevicesCount == 0) return pxcExit();
    char errorMsg[cErrBufSize];
    for (unsigned devIdx = 0; (signed)devIdx < connectedDevicesCount; devIdx++) {
    char cMsg[cErrBufSize];
        char deviceName[256];
    String^ eMsg;
        memset(deviceName, 0, 256);
    pxcGetLastError(errorMsg, cErrBufSize);
        pxcGetDeviceName(devIdx, deviceName, 256);
    if (rc!=0) {
        char chipID[256];
         sprintf(cMsg, "%s %d err: %s", fName, rc, errorMsg);
        memset(chipID, 0, 256);
         eMsg = gcnew String(errorMsg);
        pxcGetDeviceChipID(devIdx, 0, chipID, 256);
         printf("Device %d: Name %s, (first ChipID: %s)\n", devIdx, deviceName, chipID);
    }
    double bias;
    rc = pxcGetBias(devIdx, &bias);
    if (bias < 0.0) {
         if (devIdx == 0) chipType = CHT_CdTe;
        printf("Chip material detected: CdTe\n");
    } else if (bias == 0.0) {
        printf("Chip material not detected!\n");
     } else {
     } else {
         if (devIdx == 0) chipType = CHT_Si;
         sprintf(cMsg, "%s %d err: ---", fName, rc);
        printf("Chip material detected: Si\n");
     };
     }
     String^ sMsg = gcnew String(cMsg);
     printf("=================================================================\n");
     listMessages->Items->Add(sMsg);
      
     return (rc!=0);
    // here can be working code (calling some example function from this manual)
   
     return pxcExit();
  }
  }
</syntaxhighlight>
Now you can use it:<br>
<syntaxhighlight lang="C" line>
rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_EVENT_ITOT);
if (errorToList("pxcSetTimepix3Mode", rc)) return rc;
</syntaxhighlight>
</syntaxhighlight>


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetLastError
| Nam = pxcGetIPixet
| HeSym = ===
| HeSym = ===
| Sum = Returns text of last error. This function can be called even before pxcInitialize()
| Sum = Returns a core pointer for processing libraries, Clustering or Spectral imaging for example.
| DefH = PXCAPI int
| DefH = PXCAPI void*
| DefP = char* errorMsgBuffer, unsigned size
| DefP = (void)
| errorMsgBuffer - buffer where text will be saved
|  
| size - size of supplied buffer
|  
|
|
|
|
Line 402: Line 495:
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = core pointer
| Not =
| Not =
| War =
| War =
| Exa = char msg[200];
| Exa =  
pxcGetLastError(msg, 200);<br> printf("Error msg: %s\n", msg);
}}
}}
'''Example1 (console)'''
 
== Parameter Get/Set functions (direct) ==
Functions described in this chapter working directly, function name defines parameter name and type.<br>
<br>
'''For named parameters settings see:''' [[#Parameter_Get/Set_functions_(using_text_paramName)|Parameter Get/Set functions (using text paramName)]]<br>
<br>
<br>
=== Example: Setting operation mode ===
----
<syntaxhighlight lang="C" line>
<syntaxhighlight lang="C" line>
#define ERRMSG_BUFF_SIZE 512
  // Set the operating mode
#define ENTER_ON true
  rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_TOATOT);
#define ENTER_OFF false
printErrors("pxcSetTimepix3Mode", rc);
  // (the function used in most examples in this manual)
  void printErrors(const char* fName, int rc, bool enter) {
    char errorMsg[ERRMSG_BUFF_SIZE];
    pxcGetLastError(errorMsg, ERRMSG_BUFF_SIZE);
    if (errorMsg[0]>0) {
        printf("%s %d err: %s", fName, rc, errorMsg);
    } else {
        printf("%s %d err: ---", fName, rc);
    }
    if (enter) printf("\n");
}
</syntaxhighlight>
</syntaxhighlight>
Now you can use it:<br>
 
=== Example: List of devices with parameters ===
----
<syntaxhighlight lang="C" line>
<syntaxhighlight lang="C" line>
  rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_EVENT_ITOT);
  #include <stdio.h>
printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
#include "pxcapi.h"
</syntaxhighlight>
#define CHT_Si 0
If mode set was suscessfull, result is:
#define CHT_CdTe 1
: '''pxcSetTimepix3Mode 0 err: ---'''
char chipType = CHT_Unknown;
If not, you can see some as:
int main(int argc, char const* argv[]) { // #######################################
: '''pxcSetTimepix3Mode -2 err: Invalid device index'''
    int rc = pxcInitialize();
<br>
    if (rc) {
'''Example2 (Windows CLR)'''
        printf("Could not initialize Pixet:\n");
<br>
        printErrors("pxcInitialize", rc, ENTER_ON);
<syntaxhighlight lang="C" line>
        return -1;
const unsigned cErrBufSize = 512;
    }
// primary use to show function name, return code, last error message
    int connectedDevicesCount = pxcGetDevicesCount();
bool errorToList(const char* fName, int rc) {
    printf("Connected devices: %d\n", connectedDevicesCount);
    char errorMsg[cErrBufSize];
    if (connectedDevicesCount == 0) return pxcExit();
    char cMsg[cErrBufSize];
    for (unsigned devIdx = 0; (signed)devIdx < connectedDevicesCount; devIdx++) {
    String^ eMsg;
        char deviceName[256];
    pxcGetLastError(errorMsg, cErrBufSize);
        memset(deviceName, 0, 256);
    if (rc!=0) {
        pxcGetDeviceName(devIdx, deviceName, 256);
         sprintf(cMsg, "%s %d err: %s", fName, rc, errorMsg);
        char chipID[256];
         eMsg = gcnew String(errorMsg);
        memset(chipID, 0, 256);
     } else {
        pxcGetDeviceChipID(devIdx, 0, chipID, 256);
         sprintf(cMsg, "%s %d err: ---", fName, rc);
         printf("Device %d: Name %s, (first ChipID: %s)\n", devIdx, deviceName, chipID);
     };
    }
     String^ sMsg = gcnew String(cMsg);
    double bias;
     listMessages->Items->Add(sMsg);
    rc = pxcGetBias(devIdx, &bias);
     return (rc!=0);
    if (bias < 0.0) {
         if (devIdx == 0) chipType = CHT_CdTe;
        printf("Chip material detected: CdTe\n");
    } else if (bias == 0.0) {
        printf("Chip material not detected!\n");
     } else {
         if (devIdx == 0) chipType = CHT_Si;
        printf("Chip material detected: Si\n");
     }
     printf("=================================================================\n");
      
    // here can be working code (calling some example function from this manual)
   
     return pxcExit();
  }
  }
</syntaxhighlight>
Now you can use it:<br>
<syntaxhighlight lang="C" line>
rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_EVENT_ITOT);
if (errorToList("pxcSetTimepix3Mode", rc)) return rc;
</syntaxhighlight>
</syntaxhighlight>


Line 486: Line 584:
| Nam = pxcListNetworkDevices
| Nam = pxcListNetworkDevices
| HeSym = ===
| HeSym = ===
| Sum = Search for available network devices and store basic information about it to arrary.
| Sum = Searches for available network devices and store basic information about it to arrary. This is special function, independent of the Pixet Core. Can be used for listing devices without the PXcore initialized to prevent "steal" of other devices on the network. The output is usesfull to browse/testing network devices, it's IPs and availability on the network subnets.  
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = NetworkDevInfo* devInfos, unsigned* size
| DefP = NetworkDevInfo* devInfos, unsigned* size
Line 498: Line 596:
|
|
| Ret = Returns 0 if OK or PXCERR_BUFFER_SMALL if the number of devices exceeded the size of the array (the array is still filled and *size is set)  
| Ret = Returns 0 if OK or PXCERR_BUFFER_SMALL if the number of devices exceeded the size of the array (the array is still filled and *size is set)  
| Not =
| Not = 1. Can be used independent of the Pixet core.<br>2. A related feature is planned, allowing you to select devices to be used by PXcore. Currently you can write to the zest.ini instead.
| War =
| War =
| Exa = NetworkDevInfo ndi[10];
| Exa = NetworkDevInfo ndi[256];
unsigned size = 10;
unsigned ndiSize = 256;
 
int rc;
int rc = pxcListNetworkDevices(ndi, &size);
msgToList("pxcListNetworkDevices...");
printf("Network dev list:\n");
//pxcListNetworkDevices(NetworkDevInfo* devInfos, unsigned* size);
for (int i=0; (rc==0 && i<size) {{!}}{{!}} (rc<0 && i<10); i++) printf("  IP: %s, Name: %s, Serial: %d\n", ndi[i].ip, ndi[i].name, ndi[i].serial);
rc = pxcListNetworkDevices(ndi, &ndiSize);
printf("Devices found: %d\n", *size);
errorToList("pxcListNetworkDevices", rc);
if (rc<0) printf("Warning: Number of devs exceeded the array size\n");
if (rc != 0 && rc != PXCERR_BUFFER_SMALL) return;
for (int n=0; n < ndiSize; n++) {
msgToList(String::Format("  IP: {0}\t Name: {1}\t SN: {2}", gcnew String(ndi[n].ip), gcnew String(ndi[n].name), ndi[n].serial));
}
if (ndiSize == 0) msgToList(" (no devs found)");
else if (rc == PXCERR_BUFFER_SMALL) msgToList(" (and more devs than ndi array size)");
}}
}}


'''Network device info details:'''
<syntaxhighlight lang="C">
struct NetworkDevInfo{
    char ip[15];
    char name[20];
    int serial;
};
</syntaxhighlight>


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetDeviceName
| Nam = pxcGetDeviceInfo
| HeSym = ===
| HeSym = ===
| Sum = This function returns the full name of the selected device.
| Sum = Gets device info structure and returns devType. If *devInfo is NULL, only returns devType.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = (unsigned deviceIndex, char* nameBuffer, unsigned size
| DefP = unsigned deviceIndex, CDevInfo *devInfo
| deviceIndex - index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| nameBuffer - buffer where the name of the device will be saved. Cannot be NULL
| devInfo – pointer to CDevInfo struct
| size - size of the supplied name buffer  
|
|
|
|
|
|
| Ret = Device type number
| Not =
| War =
| Exa = // simple use:
if (pxcGetDeviceInfo(devIdx, NULL) != TPX3) errorMsg("The device is not Timepix3");
// Advanced use:
CDevInfo devInfo[20];
char *dtStrings[] = {"Tpx", "Mpx3", "Tpx3", "Tpx2"};
for (int n=0; n<pxcGetDevicesCount(); n++) {
    pxcGetDeviceInfo(n, devInfo[n]);
    printf("DevIdx %d: Name: %s, SN: %d, DevType: %s", n, devInfo[n].name, devInfo[n].serial, dtStrings[devInfo[n].type+1]);
}
}}
'''Device info details:'''
<syntaxhighlight lang="C">
enum DevType{
    TPX = 1, MPX3, TPX3, TPX2,
};
struct CDevInfo{
    char name[20];
    int serial;
    DevType type;
};
</syntaxhighlight>
 
 
{{ApiBinaryItem
| Nam = pxcGetDeviceName
| HeSym = ===
| Sum = This function returns the full name of the selected device.
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, char* nameBuffer, unsigned size
| deviceIndex index of the device, starting from zero
| nameBuffer buffer where the name of the device will be saved. Cannot be NULL
| size size of the supplied name buffer  
|
|
|
|
Line 530: Line 681:
| Exa = char name[100];
| Exa = char name[100];
pxcGetDeviceName(deviceIndex, name, 100);
pxcGetDeviceName(deviceIndex, name, 100);
printf("Dev %d name: %s\n", deviceIndex, msg);
printf("Dev %d name: %s\n", deviceIndex, name);
}}
}}


Line 539: Line 690:
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex
| DefP = unsigned deviceIndex
| deviceIndex - index of the device, starting from zero
| deviceIndex index of the device, starting from zero
|
|
|
|
|
Line 557: Line 709:
| Sum = This function returns the ID of chip of the detector connected to the readout device.
| Sum = This function returns the ID of chip of the detector connected to the readout device.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = (unsigned deviceIndex, unsigned chipIndex, char* chipIDBuffer, unsigned size
| DefP = unsigned deviceIndex, unsigned chipIndex, char* chipIDBuffer, unsigned size
| deviceIndex - index of the device, starting from zero
| deviceIndex index of the device, starting from zero
| chipIndex – index of the chip in the device, starting from zero
| chipIndex – index of the chip in the device, starting from zero
| chipIDBuffer - buffer where the chipID of the detector will be saved. Cannot be NULL
| chipIDBuffer buffer where the chipID of the detector will be saved. Cannot be NULL
| size - size of the supplied chipID buffer
| size - size of the supplied chipID buffer
|
|
Line 567: Line 719:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa = char id[50];
| Exa = char id[50];
int rc = pxcGetDeviceChipID(deviceIndex, 0, id, 50);
int rc = pxcGetDeviceChipID(deviceIndex, 0, id, 50);
if (rc==0) printf("Chip 0 of dev %d have ID: %s\n", deviceIndex, msg);
if (rc==0) printf("Chip 0 of dev %d have ID: %s\n", deviceIndex, id);
else printf("pxcGetDeviceChipID failed, code: %d\n", rc);
else printf("pxcGetDeviceChipID failed, code: %d\n", rc);
}}
}}
Line 744: Line 898:
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| Not =
| War =
| War = Too low thl value cause many noising pixels with all related problems.
| War = Too low thl value cause many noising pixels with all related problems.
| Exa = int rc = pxcSetThreshold(1, 0, 4.5); // set threshold with idx 0 on device with idx 1 to the 4.5 keV.
| Exa = int rc = pxcSetThreshold(1, 0, 4.5); // set threshold with idx 0 on device with idx 1 to the 4.5 keV.
Line 800: Line 953:
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| clock – pointer to double variable where the clock will be saved
| clock – pointer to double variable where the clock will be saved
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
|
|
|
|
Line 806: Line 958:
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN. Timepix3 has a fixed clock of 40 MHz. Timepix2 has other clocks managenment.
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN. Timepix3 has a fixed clock of 40 MHz. Timepix2 has other clocks managenment.
| Not =
| War =
| War =
| Exa = double val;
| Exa = double val;
Line 830: Line 983:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| War =
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN. Timepix3 has a fixed clock of 40 MHz. Timepix2 has other clocks managenment.
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN. Timepix3 has a fixed clock of 40 MHz. Timepix2 has other clocks managenment.
Line 843: Line 995:
| DefP = unsigned deviceIndex
| DefP = unsigned deviceIndex
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
|
|
|
|
|
Line 856: Line 1,009:
: Otherwise the return value is a PXCERR_XXX code.
: Otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN.
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN.
| Not =
| War =
| War =
| Exa = int rc = pxcGetTimepixMode(deviceIndex);
| Exa = int rc = pxcGetTimepixMode(deviceIndex);
if (rc>=0) printf("Mode of dev. idx %d is: %d\n", rc);
if (rc>=0) printf("Mode of dev. idx %d is: %d\n", deviceIndex, rc);
else printf("pxcGetTimepixMode failed, code %d\n", rc);
else printf("pxcGetTimepixMode failed, code %d\n", rc);
}}
}}
Line 881: Line 1,033:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| War =
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN.
| Not = Only for the Timepix devices, not usable on Timepix3 and other TimepixN.
Line 1,065: Line 1,216:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = ou need different acquisition or frame reading functions if calibration is on or off.
| Not = Different acquisition or frame reading functions needed if calibration is on or off.
:Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.
:Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.
| War =
| War =
Line 1,086: Line 1,237:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = You need different acquisition or frame reading functions if calibration is on or off.
| Not = Different acquisition or frame reading functions needed if calibration is on or off.
:Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.
:Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.
| War =
| War =
Line 1,113: Line 1,264:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetMedipix3OperationMode
| Nam = pxcSetTimepix3CalibrationEnabled
| HeSym = ===
| HeSym = ===
| Sum = Sets the operation mode of Medipix3 detector
| Sum = Enables/disables the calibration of Timepix3 ToT counts to energy in keV. If enabled, output of a frame maesurements on the device will be calibrated.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, int opMode
| DefP = unsigned deviceIndex, bool enabled
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| opMode mode of the detector PXC_MPX3_OPM_XXX values
| enabled if calibraiton is enabled
|
|
|
|
Line 1,127: Line 1,278:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Medipix3 devices, not usable on Timepixes or other Medipixes.
| Not = Calibration working properly only if the device has loaded proper config.
| War =
| War =
| Exa =
| Exa =
Line 1,133: Line 1,284:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetMedipix3GainMode
| Nam = pxcIsTimepix3CalibrationEnabled
| HeSym = ===
| HeSym = ===
| Sum = Sets the gain mode of Medipix3 detector
| Sum = Gets if the calibration of Timepix3 ToT counts to energy in keV is enabled. See [[#pxcSetTimepix3CalibrationEnabled|pxcSetTimepix3CalibrationEnabled]] for details.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, int gain
| DefP = unsigned deviceIndex
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| gain – mode of the detector PXC_MPX3_GAIN_MOD_XXX values
|
|
|
|
Line 1,146: Line 1,296:
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
|
| Not = Only for the Medipix3 devices, not usable on Timepixes or other Medipixes.
| Ret = enabled > 0, disabled = 0, error < 0 – the return value is a PXCERR_XXX code.
| Not =
| War =
| War =
| Exa =
| Exa =
Line 1,153: Line 1,304:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetMedipix3AcqParams
| Nam = pxcSetMedipix3OperationMode
| HeSym = ===
| HeSym = ===
| Sum = Sets acquisition parameters for Medipix3
| Sum = Sets the operation mode of Medipix3 detector
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, bool colorMode, bool csm, int gain, bool equalize
| DefP = unsigned deviceIndex, int opMode
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| colorMode if color mode is enabled
| opMode – mode of the detector PXC_MPX3_OPM_XXX values
| csm – if charge sharing mode is enabled
|
| gain – gain settings (PXC_MPX3_GAIN_XXX values)
|
| equalize – if equalization bit in Medipix3 is enabled
|
|
|
|
|
Line 1,173: Line 1,324:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetMedipix3MatrixParams
| Nam = pxcSetMedipix3GainMode
| HeSym = ===
| HeSym = ===
| Sum = Sets parameters of the Meidpix3 pixel matrix
| Sum = Sets the gain mode of Medipix3 detector
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, int depth, int counter, int colBlock, int rowBlock
| DefP = unsigned deviceIndex, int gain
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| depth depth of the counters PXC_MPX3_CNTD_XXX values
| gain mode of the detector PXC_MPX3_GAIN_MOD_XXX values
| counter – selected counter (PXC_MPX3_CNT_XXX values)
|
| colBlock – region of interest readout (PXC_MPX3_COLB_XXX values)
|
| rowBlock – region of interest readout (PXC_MPX3_ROWB_XXX values)
|
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Medipix3 devices, not usable on Timepix or other Medipixes.
| Not = Only for the Medipix3 devices, not usable on Timepixes or other Medipixes.
| War =
| War =
| Exa =
| Exa =
Line 1,193: Line 1,344:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetPixelMatrix
| Nam = pxcSetMedipix3AcqParams
| HeSym = ===
| HeSym = ===
| Sum = Sets the pixel matrix configuration. This is low level function for advanced users.
| Sum = Sets acquisition parameters for Medipix3
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned char* maskMatrix, unsigned size
| DefP = unsigned deviceIndex, bool colorMode, bool csm, int gain, bool equalize
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| maskMatrix pixel mask matrix. 0 = masked, 1= unmasked
| colorMode if color mode is enabled
| size size of the mask matrix
| csm if charge sharing mode is enabled
|
| gain – gain settings (PXC_MPX3_GAIN_XXX values)
| equalize – if equalization bit in Medipix3 is enabled
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| Not = Only for the Medipix3 devices, not usable on Timepixes or other Medipixes.
| War =
| War =
| Exa =
| Exa =
Line 1,212: Line 1,364:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetPixelMatrix
| Nam = pxcSetMedipix3MatrixParams
| HeSym = ===
| HeSym = ===
| Sum = Gets the pixel matrix configuration. This is low level function for advanced users.
| Sum = Sets parameters of the Meidpix3 pixel matrix
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned char* maskMatrix, unsigned byteSize
| DefP = unsigned deviceIndex, int depth, int counter, int colBlock, int rowBlock
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| maskMatrix buffer where the mask matrix will be stored. 0=masked, 1=unmasked
| depth depth of the counters PXC_MPX3_CNTD_XXX values
| size size of the mask matrix
| counter – selected counter (PXC_MPX3_CNT_XXX values)
|
| colBlock region of interest readout (PXC_MPX3_COLB_XXX values)
| rowBlock – region of interest readout (PXC_MPX3_ROWB_XXX values)
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| Not = Only for the Medipix3 devices, not usable on Timepix or other Medipixes.
| War =
| War =
| Exa =
| Exa =
}}
}}
== Metadata ==
----
Various devices, readout chips, detector chips and measurement methods have various metadata. To obtain informations about all relevant metadata for your purphose, set-up and run the testmeasurement with file-saving (using test code or Pixet program). Now you can read the accompanying DSC/INFO files, that contains all metadata for this combination of device/detector/measurement.<br>
[[File:Frames and description files screenshot.png|frame|right|alt=Frames and description files screenshot|Frames and description files screenshot]]
;Example DSC records
:"Chips layout" ("Order of chips in matrix"):
:i32[5]
:4 3 0 1 2
:
:"Start time" ("Acquisition start time"):
:double[1]
:1659611081.595321
:
:"Start time (string)" ("Acquisition start time (string)"):
:char[64]
:Thu Aug 4 13:04:41.595321 2022


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetMetaDataValue
| Nam = pxcSetPixelMatrix
| HeSym = ===
| HeSym = ===
| Sum = This function gets measured data meta data value. Output value is converted to char*.
| Sum = Sets the pixel matrix configuration. This is low level function for advanced users.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned dataIndex, const char* metaDataName, char* valueBuffer, unsigned* size
| DefP = unsigned deviceIndex, unsigned char* maskMatrix, unsigned size
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| dataIndex - index of the measured data (frame), starting from zero
| maskMatrix – pixel mask matrix. 0 masked, 1 unmasked
| metaDataName name of the metadata to get, "Start time" for example
| size size of the mask matrix
| valueBuffer – buffer where the value of the meta data as string will be stored
|
| size – pointer to size of the supplied buffer
|
|
|
|
|
Line 1,264: Line 1,400:
| Not =
| Not =
| War =
| War =
| Exa = char mdb[200]; // metadata buffer
| Exa =
unsigned mdbs = 200; // metadata buffer size
char mdn[] = "Start time"; // metadata name
 
int rc = pxcGetMetaDataValue(deviceIndex, frameLastIndex, mdn, mdb, &mdbs);
if (rc != 0) errorToList("pxcGetMetaDataValue", rc);
else msgToList("Acquisition start time: " + gcnew String(mdb));
}}
}}
== Parameter Get/Set functions (using text paramName) ==
----
In this chapter are a functions that working with named parameters. Alias '''readout parameters''': Because originally it was only about the parameters of the readout chips. Later, the setting of other device and software parameters was also added.<br>
'''Example:'''
<syntaxhighlight lang="C">
// Data Driven Block Size [B], default 66000
rc = pxcSetDeviceParameter(deviceIndex, "DDBlockSize", 6000);
printf("pxcSetDeviceParameter %d", rc);
</syntaxhighlight>
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetDeviceParameter
| Nam = pxcGetPixelMatrix
| HeSym = ===
| HeSym = ===
| Sum = Returns the value of integer device parameter (e.g. settings of trigger)
| Sum = Gets the pixel matrix configuration. This is low level function for advanced users.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, const char* parameterName
| DefP = unsigned deviceIndex, unsigned char* maskMatrix, unsigned byteSize
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| parameterName name of the device parameter
| maskMatrix buffer where the mask matrix will be stored. 0 masked, 1 unmasked
|
| size – size of the mask matrix
|
|
|
|
Line 1,303: Line 1,422:
| Exa =
| Exa =
}}
}}
== Metadata ==
Various devices, readout chips, detector chips and measurement methods have various metadata. To obtain informations about all relevant metadata for your purphose, set-up and run the testmeasurement with file-saving (using test code or Pixet program). Now you can read the accompanying DSC/INFO files, that contains all metadata for this combination of device/detector/measurement.<br>
[[File:Frames and description files screenshot.png|frame|right|alt=Frames and description files screenshot|Frames and description files screenshot]]
;Example DSC records
:"Chips layout" ("Order of chips in matrix"):
:i32[5]
:4 3 0 1 2
:
:"Start time" ("Acquisition start time"):
:double[1]
:1659611081.595321
:
:"Start time (string)" ("Acquisition start time (string)"):
:char[64]
:Thu Aug 4 13:04:41.595321 2022


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetDeviceParameter
| Nam = pxcGetMetaDataValue
| HeSym = ===
| HeSym = ===
| Sum = Sets a value of the integer device parameter (e.g. settings of trigger)
| Sum = This function gets measured data meta data value. Output value is converted to char*.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, const char* parameterName, int parameterValue
| DefP = unsigned deviceIndex, unsigned dataIndex, const char* metaDataName, char* valueBuffer, unsigned* size
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| parameterName – name of the device parameter
| dataIndex - index of the measured data (frame), starting from zero
| parameterValue new value of the parameter
| metaDataName – name of the metadata to get, "Start time" for example
|
| valueBuffer buffer where the value of the meta data as string will be stored
|
| size – pointer to size of the supplied buffer
|
|
|
|
Line 1,321: Line 1,456:
| Not =
| Not =
| War =
| War =
| Exa =
| Exa = char mdb[200]; // metadata buffer
unsigned mdbs = 200; // metadata buffer size
char mdn[] = "Start time"; // metadata name
 
int rc = pxcGetMetaDataValue(deviceIndex, frameLastIndex, mdn, mdb, &mdbs);
if (rc != 0) errorToList("pxcGetMetaDataValue", rc);
else msgToList("Acquisition start time: " + gcnew String(mdb));
}}
}}
== Parameter Get/Set functions (using text paramName) ==
In this chapter are a functions that working with named parameters. Alias '''readout parameters''': Because originally it was only about the parameters of the readout chips. Later, the setting of other device and software parameters was also added.<br>
<br>
'''For dirrect setting functions see:''' [[#Parameter_Get/Set_functions_(direct)|Parameter Get/Set functions (direct)]]<br>
<br>
'''Example:'''
<syntaxhighlight lang="C">
// Data Driven Block Size [B], default 66000
rc = pxcSetDeviceParameter(deviceIndex, "DDBlockSize", 6000);
printf("pxcSetDeviceParameter %d", rc);
</syntaxhighlight>
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetDeviceParameterDouble
| Nam = pxcGetDeviceParameter
| HeSym = ===
| HeSym = ===
| Sum = Returns the value of device double parameter
| Sum = Returns the value of integer device parameter (e.g. settings of trigger)
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, const char* parameterName, double* parameterValue
| DefP = unsigned deviceIndex, const char* parameterName
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| parameterName – name of the device parameter
| parameterName – name of the device parameter
| parameterValue – pointer to double variable where the parameter value will be saved
|
|
|
|
|
Line 1,345: Line 1,499:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetDeviceParameterDouble
| Nam = pxcSetDeviceParameter
| HeSym = ===
| HeSym = ===
| Sum = Sets a value of the device double parameter
| Sum = Sets a value of the integer device parameter (e.g. settings of trigger)
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, const char* parameterName, double parameterValue
| DefP = unsigned deviceIndex, const char* parameterName, int parameterValue
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| parameterName – name of the device parameter
| parameterName – name of the device parameter
Line 1,365: Line 1,519:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetDeviceParameterString
| Nam = pxcGetDeviceParameterDouble
| HeSym = ===
| HeSym = ===
| Sum = Returns the value of device string parameter
| Sum = Returns the value of device double parameter
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, const char* parameterName, const char* parameterValue, unsigned size
| DefP = unsigned deviceIndex, const char* parameterName, double* parameterValue
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| parameterName – name of the device parameter
| parameterName – name of the device parameter
| parameterValue – pointer to string buffer where the parameter value will be saved
| parameterValue – pointer to double variable where the parameter value will be saved
| size – size of the passed buffer
|
|
|
|
|
Line 1,385: Line 1,539:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSetDeviceParameterString
| Nam = pxcSetDeviceParameterDouble
| HeSym = ===
| HeSym = ===
| Sum = Sets a value of the device string parameter
| Sum = Sets a value of the device double parameter
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, const char* parameterName, const char* parameterValue
| DefP = unsigned deviceIndex, const char* parameterName, double parameterValue
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| parameterName – name of the device parameter
| parameterName – name of the device parameter
Line 1,404: Line 1,558:
}}
}}


=== Tpx3 parameter names list ===
{{ApiBinaryItem
----
| Nam = pxcGetDeviceParameterString
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''
| HeSym = ===
<syntaxhighlight lang="C">
| Sum = Returns the value of device string parameter
#define PAR_LIBVER        "HwLibVer"
| DefH = PXCAPI int
#define PAR_DEBUGLOG      "DebugLog"
| DefP = unsigned deviceIndex, const char* parameterName, const char* parameterValue, unsigned size
#define PAR_DUMMYACQ      "DummyAcqNegativePolarity"
| deviceIndex – index of the device, starting from zero
#define PAR_TEMP          "Temperature"
| parameterName – name of the device parameter
#define PAR_TEMP_CHIP    "TemperatureChip"
| parameterValue – pointer to string buffer where the parameter value will be saved
#define PAR_TEMP_CPU      "TemperatureCpu" // mimipix/tpx3 only
| size – size of the passed buffer
#define PAR_TEMP_CHIP_CPU "TemperatureChipCpu" // mimipix/tpx3 only
|
#define PAR_TEMP_READ_ACQSERIE "TemperatureReadBeforeAcqSerie" // mimipix/tpx3 only
|
#define PAR_TEMP_READ_EVERYACQ "TemperatureReadBeforeEachAcq" // mimipix/tpx3 only
|
#define PAR_TEMP_CHECK_IN_SW "CheckMaxTempInSW" // mimipix/tpx3 only
|
#define PAR_TEMP_CHECK_IN_CPU "CheckMaxChipTempInCPU" // mimipix/tpx3 only
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
#define PAR_TEMP_MAX_ALLOWED_TEMP "MaxAllowedChipTemp" // mimipix/tpx3 only
| Not =
#define PAR_DAC_BANGAP      "DacBandGap"
| War =
#define PAR_DAC_TEMP        "DacTemp"
| Exa =
#define PAR_BIAS_SENSE_VOLT "BiasSenseVoltage"
}}
#define PAR_BIAS_SENSE_CURR "BiasSenseCurrent"
 
#define PAR_DD_BUFF_SIZE    "DDBuffSize"
{{ApiBinaryItem
#define PAR_DD_BLOCK_SIZE  "DDBlockSize"
| Nam = pxcSetDeviceParameterString
#define META_SHUTTER_TIME  "Shutter open time" // mimipix/tpx3 only
| HeSym = ===
#define PAR_CHAN_MASK      "ChanMask" // no net/tpx3
| Sum = Sets a value of the device string parameter
#define PAR_READOUT_CLOCK  "ReadoutClock" // no net/tpx3
| DefH = PXCAPI int
#define PAR_TRG_STG        "TrgStg"
| DefP = unsigned deviceIndex, const char* parameterName, const char* parameterValue
#define PAR_TRG_TIMESTAMP  "TrgTimestamp"
| deviceIndex – index of the device, starting from zero
#define PAR_TRG_T0SYNC_RESET "TrgT0SyncReset"
| parameterName – name of the device parameter
#define PAR_TRG_READY        "TrgReady" // no net/tpx3
| parameterValue – new value of the parameter
#define PAR_TRG_OUTLEVEL    "TrgOutLevel" // mimipix/tpx3 only
|
#define PAR_TRG_OUT_ENABLE  "TrgOutEnable" // mimipix/tpx3 only
|
#define PAR_TRG_IS_MASTER    "IsMaster"
|
#define PAR_MOTOHOURS        "Motohours" // mimipix/tpx3 only
|
#define PAR_MTX              "MTX" // mimipix/tpx3 only
|
#define PAR_SEND_TOA_PIXELS  "SendDummyToaPixels" // mimipix/tpx3 only
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
#define PAR_DUMMYSPEED      "DDDummyDataSpeed" // no mimipix/tpx3
| Not =
#define PAR_BLOCKCOUNT      "BlockCount" // no mimipix/tpx3
| War =
#define PAR_PROCESSDATA      "ProcessData" // no mimipix/tpx3
| Exa =
#define PAR_TRG_MULTI        "TrgMulti" // no mimipix/tpx3
}}
#define PAR_ADVAPIX_ADC      "AdvaPixADC" // no mimipix/tpx3
#define PAR_TRG_READY        "TrgReady" // zem only
#define PAR_TRG_CMOS        "TrgCmos" // zem only
#define PAR_READOUT_CLOCK    "ReadoutClock" // zem only
</syntaxhighlight>


=== Tpx2 parameter names list ===
=== Tpx3 parameter names list ===
----
----
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''
<syntaxhighlight lang="C">
<syntaxhighlight lang="C">
const static char* PAR_LIBVER = "HwLibVer";
#define PAR_LIBVER       "HwLibVer"
const static char* PAR_DEBUGLOG = "DebugLog";
#define PAR_DEBUGLOG     "DebugLog"
const static char* PAR_BIAS_SENSE_VOLT = "BiasSenseVoltage";
#define PAR_DUMMYACQ      "DummyAcqNegativePolarity"
const static char* PAR_BIAS_SENSE_CURR = "BiasSenseCurrent";
#define PAR_TEMP          "Temperature"
const static char* PAR_READOUT_CLOCK = "ReadoutClock";
#define PAR_TEMP_CHIP    "TemperatureChip"
const static char* PAR_TRG_STG = "TrgStg";
#define PAR_TEMP_CPU      "TemperatureCpu" // mimipix/tpx3 only
const static char* PAR_TRG_IS_MASTER = "IsMaster";
#define PAR_TEMP_CHIP_CPU "TemperatureChipCpu" // mimipix/tpx3 only
const static char* PAR_MOTOHOURS = "Motohours";
#define PAR_TEMP_READ_ACQSERIE "TemperatureReadBeforeAcqSerie" // mimipix/tpx3 only
const static char* PAR_TEMP_CPU = "TemperatureCpu";
#define PAR_TEMP_READ_EVERYACQ "TemperatureReadBeforeEachAcq" // mimipix/tpx3 only
const static char* PAR_TEMP_MAX_ALLOWED_TEMP = "MaxAllowedChipTemp";
#define PAR_TEMP_CHECK_IN_SW "CheckMaxTempInSW" // mimipix/tpx3 only
const static char* PAR_POWER_VOLT = "PowerSupplyVoltage";
#define PAR_TEMP_CHECK_IN_CPU "CheckMaxChipTempInCPU" // mimipix/tpx3 only
const static char* PAR_CPU_SUPPLY_VOLT = "CPUSupplyVoltage";
#define PAR_TEMP_MAX_ALLOWED_TEMP "MaxAllowedChipTemp" // mimipix/tpx3 only
const static char* PAR_CHIP_LDO_VOLT = "ChipLDOVoltage";
#define PAR_DAC_BANGAP      "DacBandGap"
const static char* PAR_INPUT_CURRENT = "DeviceInputCurrent";
#define PAR_DAC_TEMP        "DacTemp"
const static char* PAR_CHIP_CURRENT = "ChipCurrent";
#define PAR_BIAS_SENSE_VOLT "BiasSenseVoltage"
</syntaxhighlight>
#define PAR_BIAS_SENSE_CURR "BiasSenseCurrent"
#define PAR_DD_BUFF_SIZE    "DDBuffSize"
#define PAR_DD_BLOCK_SIZE  "DDBlockSize"
#define META_SHUTTER_TIME  "Shutter open time" // mimipix/tpx3 only
#define PAR_CHAN_MASK      "ChanMask" // no net/tpx3
#define PAR_READOUT_CLOCK   "ReadoutClock" // no net/tpx3
#define PAR_TRG_STG         "TrgStg"
#define PAR_TRG_TIMESTAMP  "TrgTimestamp"
#define PAR_TRG_T0SYNC_RESET "TrgT0SyncReset"
#define PAR_TRG_READY        "TrgReady" // no net/tpx3
#define PAR_TRG_OUTLEVEL    "TrgOutLevel" // mimipix/tpx3 only
#define PAR_TRG_OUT_ENABLE  "TrgOutEnable" // mimipix/tpx3 only
#define PAR_TRG_IS_MASTER   "IsMaster"
#define PAR_MOTOHOURS       "Motohours" // mimipix/tpx3 only
#define PAR_MTX              "MTX" // mimipix/tpx3 only
#define PAR_SEND_TOA_PIXELS  "SendDummyToaPixels" // mimipix/tpx3 only
#define PAR_DUMMYSPEED      "DDDummyDataSpeed" // no mimipix/tpx3
#define PAR_BLOCKCOUNT      "BlockCount" // no mimipix/tpx3
#define PAR_PROCESSDATA      "ProcessData" // no mimipix/tpx3
#define PAR_TRG_MULTI        "TrgMulti" // no mimipix/tpx3
#define PAR_ADVAPIX_ADC      "AdvaPixADC" // no mimipix/tpx3
#define PAR_TRG_READY        "TrgReady" // zem only
#define PAR_TRG_CMOS        "TrgCmos" // zem only
#define PAR_READOUT_CLOCK    "ReadoutClock" // zem only
</syntaxhighlight>


=== Mpx2 (Timepix) parameter names list ===
=== Tpx2 parameter names list ===
----
----
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''
<syntaxhighlight lang="C">
<syntaxhighlight lang="C">
#define PAR_LIBVER        "HwLibVer" // all, include minipixes
const static char* PAR_LIBVER = "HwLibVer";
#define PAR_DEBUGLOG      "DebugLog" // all, include minipixes
const static char* PAR_DEBUGLOG = "DebugLog";
#define CFG_BINPIXCFG    "BinaryPixelCfg" // fei-minipix only
const static char* PAR_BIAS_SENSE_VOLT = "BiasSenseVoltage";
const static char* PAR_BIAS_SENSE_CURR = "BiasSenseCurrent";
const static char* PAR_READOUT_CLOCK = "ReadoutClock";
const static char* PAR_TRG_STG = "TrgStg";
const static char* PAR_TRG_IS_MASTER = "IsMaster";
const static char* PAR_MOTOHOURS = "Motohours";
const static char* PAR_TEMP_CPU = "TemperatureCpu";
const static char* PAR_TEMP_MAX_ALLOWED_TEMP = "MaxAllowedChipTemp";
const static char* PAR_POWER_VOLT = "PowerSupplyVoltage";
const static char* PAR_CPU_SUPPLY_VOLT = "CPUSupplyVoltage";
const static char* PAR_CHIP_LDO_VOLT = "ChipLDOVoltage";
const static char* PAR_INPUT_CURRENT = "DeviceInputCurrent";
const static char* PAR_CHIP_CURRENT = "ChipCurrent";
</syntaxhighlight>
 
=== Mpx2 (Timepix) parameter names list ===
----
'''Warning: Most parameters are for testing purposes only and you will not need them in normal use.'''
<syntaxhighlight lang="C">
#define PAR_LIBVER        "HwLibVer" // all, include minipixes
#define PAR_DEBUGLOG      "DebugLog" // all, include minipixes
#define CFG_BINPIXCFG    "BinaryPixelCfg" // fei-minipix only
#define PAR_FIRMWARE      "Firmware" //widepix only
#define PAR_FIRMWARE      "Firmware" //widepix only
#define PAR_PS_COUNT      "PreShutterClockCount"
#define PAR_PS_COUNT      "PreShutterClockCount"
Line 1,645: Line 1,839:
| event – event name (PXC_ACQEVENT_XXX values)
| event – event name (PXC_ACQEVENT_XXX values)
| func – callback function of type AcqFunc
| func – callback function of type AcqFunc
| userData – user data that are passed to callback function
| userData – user data pointer that was used in pxcRegisterAcqEvent, for proper indetify the event
|
|
|
|
Line 1,745: Line 1,939:
| Exa =
| Exa =
}}
}}
= API frame-based measuring functions =
[[File:Basic-measuring-example.png|frame|none|alt=Basic frame measuring example|Basic frame measuring example]]
The functions described in this chapter are used for frame-based measurements. Suitable for imaging, for example. After acquisition ends, you can read all the frame data (65536 pixels from every chip) to your buffer or save to the file. Acquisition can start by software (afther call a function, for example), or by HW trigger. Data types depends on chip technology and the operation mode.<br>
<br>
Chip can generate one or two data blocks (event count and integrated times over threshold, for example) in one acquisition. Do not forget to set the operation mode. If mode not set, some devices measure something, but some other devices measure something else in this case.<br>
;Example projects
:MiniPixTpx3-Frames – mode set, single frame, multiple frames with/without callback, continuous measuring


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcMeasureSingleFrame
| Nam = pxcIsReadyForSoftwareTrigger
| HeSym = ===
| HeSym = ===
| Sum = Performs a measurement of single frame and returns its data
| Sum = Checks if the device is ready to accept software trigger.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, double frameTime, unsigned short* frameData, unsigned* size, unsigned trgstg
| DefP = unsigned deviceIndex
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameTime – time of the measurment in seconds
|  
| frameData – pointer to buffer where data will be saved. For single detector size is 65536
|
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
|
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
|
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 1 if ready, 0 if not ready, and negative if error, PXCERR_XXX code.
| Not = This function have only one framebuffer. This is fully sufficient for single-output devices and modes. In combined modes (ToA+ToT, Event+IToT, dual threshold) only first data are available (ToA, Event, Threshold0). To take both outputs from the combined modes, it is necessary to use specialized functions for the given type of detector.
| Not = If you want to use this immediately after a function for starting acquisition, wait until it's ready by using pxcIsReadyForSoftwareTrigger.
| War =
| War =
| Exa =
| Exa = int rc = pxcIsReadyForSoftwareTrigger(deviceIndex);
if (rc==1) msgToList("Dev is ready to SW trigger");
else if (rc==0) msgToList("Dev is not ready to SW trigger");
else errorToList("pxcIsReadyForSoftwareTrigger", rc);
}}
}}


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcMeasureSingleFrameMpx3
| Nam = pxcDoSoftwareTrigger
| HeSym = ===
| HeSym = ===
| Sum = Performs a measurement of single frame and returns its data. This is only for Medipix3 chips
| Sum = Sends the software trigger: Start of acquisition with trgStg=PXC_TRG_SWSTART used.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, double frameTime, unsigned* frameData1, unsigned* frameData2, unsigned* size, unsigned trgstg
| DefP = unsigned deviceIndex
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameTime – time of the measurment in seconds
|  
| frameData1 – pointer to buffer where data from first counter will be saved. For single detector chip, size is 65536
|
| frameData2 – pointer to buffer where data from second counter will be saved. For single detector chip, size is 65536
|
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
|
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Medipix3 devices, not usable on Timepix or other Medipixes.
| Not =  
| War =
| War =
| Exa =
| Exa =  
}}
}}


{{ApiBinaryItem
= API frame-based measuring functions =
| Nam = pxcMeasureSingleFrameTpx3
[[File:Basic-measuring-example.png|frame|none|alt=Basic frame measuring example|Basic frame measuring example]]
| HeSym = ===
The functions described in this chapter are used for frame-based measurements. Suitable for imaging, for example. After acquisition ends, you can read all the frame data (65536 pixels from every chip) to your buffer or save to the file. Acquisition can start by software (afther call a function, for example), or by HW trigger. Data types depends on chip technology and the operation mode.<br>
| Sum = Performs a measurement of single frame and returns its data. This is only for Timepix3 detector.
<br>
Chip can generate one or two data blocks (event count and integrated times over threshold, for example) in one acquisition. Do not forget to set the operation mode. If mode not set, some devices measure something, but some other devices measure something else in this case.<br>
 
;Example projects
:MiniPixTpx3-Frames – mode set, single frame, multiple frames with/without callback, continuous measuring
 
{{ApiBinaryItem
| Nam = pxcMeasureSingleFrame
| HeSym = ===
| Sum = Performs a measurement of single frame and returns its data
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, double frameTime, double* frameToaITot, unsigned short* frameTotEvent, unsigned* size, unsigned trgstg
| DefP = unsigned deviceIndex, double frameTime, unsigned short* frameData, unsigned* size, unsigned trgstg
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameTime – time of the measurment in seconds
| frameTime – time of the measurment in seconds
| frameToaITot – pointer to buffer where data from ToA or iToT counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| frameData – pointer to buffer where data will be saved. For single detector size is 65536
| frameTotEvent – pointer to buffer where data from ToT or Event counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix3 devices, not usable on other Timepixes or Medipixes.
| Not = This function have only one framebuffer. This is fully sufficient for single-output devices and modes. In combined modes (ToA+ToT, Event+IToT, dual threshold) only first data are available (ToA, Event, Threshold0). To take both outputs from the combined modes, it is necessary to use specialized functions for the given type of detector.
| War =
| War =
| Exa =void pxcMeasureSingleFrameTpx3Test(unsigned di) { // di – device index ========
| Exa =
  int rc;                              // return codes
  const unsigned cSize = 65536;        // chip pixels count
  unsigned short frameTotEvent[cSize];  // frame data - event count
  double frameToaITot[cSize];          // frame data - integrated time over threshold
  double time = 1.0;                    // frame acquisition time
  unsigned size = cSize;                // buffer size and measured data size
  int mode = PXC_TPX3_OPM_EVENT_ITOT;
  rc = pxcSetTimepix3Mode(di, mode);
  printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
  rc = pxcMeasureSingleFrameTpx3(di, time, frameToaITot, frameTotEvent, &size, PXC_TRG_NO);
  printErrors("pxcMeasureSingleFrameTpx3", rc, ENTER_ON);
  showFrameDual(frameTotEvent, frameToaITot, mode);
}
}}
}}


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcMeasureSingleFrameTpx2
| Nam = pxcMeasureSingleFrameMpx3
| HeSym = ===
| HeSym = ===
| Sum = Performs a measurement of single frame and returns its data. This is only for Timepix2 detector and '''only if calibration is disabled'''
| Sum = Performs a measurement of single frame and returns its data. This is only for Medipix3 chips
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, double frameTime, unsigned* frameData1, unsigned* frameData2, unsigned* size, unsigned trgStg
| DefP = unsigned deviceIndex, double frameTime, unsigned* frameData1, unsigned* frameData2, unsigned* size, unsigned trgstg
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameTime – time of the measurment in seconds
| frameTime – time of the measurment in seconds
| frameData1 – pointer to buffer where data from the first counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| frameData1 – pointer to buffer where data from first counter will be saved. For single detector chip, size is 65536
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| frameData2 – pointer to buffer where data from second counter will be saved. For single detector chip, size is 65536
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
Line 1,843: Line 2,027:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
| Not = Only for the Medipix3 devices, not usable on Timepix or other Medipixes.
: Only if Timepix2 calibration is disabled.
| War =
| War =
| Exa =void pxcMeasureSingleFrameTpx2Test(unsigned di) { // di – device index ========
| Exa =
  int rc;                        // return codes
  const unsigned cSize = 65536;  // chip pixels count
  unsigned frameData1[cSize];    // frame data - ToT data
  unsigned frameData2[cSize];    // frame data - ToA data
  double time = 1.0;            // frame acquisition time
  unsigned size = cSize;        // buffer size and measured data size
  int mode = PXC_TPX2_OPM_TOT10_TOA18;
  rc = pxcSetTimepix2Mode(di, mode);
  printErrors("pxcSetTimepix2Mode", rc, ENTER_ON);
  rc = pxcMeasureSingleFrameTpx2(di, time, frameData1, frameData2, &size, PXC_TRG_NO);
  printErrors("pxcMeasureSingleFrameTpx2", rc, ENTER_ON);
  showFrameDual(frameData1, frameData2, mode);
}
}}
}}


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcMeasureSingleCalibratedFrameTpx2
| Nam = pxcMeasureSingleFrameTpx3
| HeSym = ===
| HeSym = ===
| Sum = Performs a measurement of single frame, calibrate ToT to energy and returns data. This is only for Timepix2 detector and '''only if calibration is enabled'''
| Sum = Performs a measurement of single frame and returns its data. This is only for Timepix3 detector.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, double frameTime, double* frameData1, unsigned* frameData2, unsigned* size, unsigned trgStg
| DefP = unsigned deviceIndex, double frameTime, double* frameToaITot, unsigned short* frameTotEvent, unsigned* size, unsigned trgstg
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameTime – time of the measurment in seconds
| frameTime – time of the measurment in seconds
| frameData1 – pointer to buffer where data from the first counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| frameToaITot – pointer to buffer where data from ToA or iToT counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| frameTotEvent – pointer to buffer where data from ToT or Event counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
Line 1,877: Line 2,047:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
| Not = Only for the Timepix3 devices, not usable on other Timepixes or Medipixes.
: Only if Timepix2 calibration is enabled.
| War =
| War =
| Exa =void pxcMeasureSingleCalibratedFrameTpx2Test(unsigned di) { // di – device index =====
| Exa =void pxcMeasureSingleFrameTpx3Test(unsigned di) { // di – device index ========
   int rc;                       // return codes
   int rc;                               // return codes
   const unsigned cSize = 65536; // chip pixels count
   const unsigned cSize = 65536;         // chip pixels count
   double frameData1[cSize];     // frame data - ToT data = calibrated to energy
   unsigned short frameTotEvent[cSize]; // frame data - event count
   unsigned frameData2[cSize];   // frame data - ToA data
   double frameToaITot[cSize];           // frame data - integrated time over threshold
   double time = 1.0;             // frame acquisition time
   double time = 1.0;                   // frame acquisition time
   unsigned size = cSize;         // buffer size and measured data size
   unsigned size = cSize;               // buffer size and measured data size
   int mode = PXC_TPX2_OPM_TOT10_TOA18;
   int mode = PXC_TPX3_OPM_EVENT_ITOT;
   rc = pxcSetTimepix2Mode(di, mode);
   rc = pxcSetTimepix3Mode(di, mode);
   printErrors("pxcSetTimepix2Mode", rc, ENTER_ON);
   printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
   rc = pxcMeasureSingleCalibratedFrameTpx2(di, time, frameData1, frameData2, &size, PXC_TRG_NO);
   rc = pxcMeasureSingleFrameTpx3(di, time, frameToaITot, frameTotEvent, &size, PXC_TRG_NO);
   printErrors("pxcMeasureSingleCalibratedFrameTpx2", rc, ENTER_ON);
   printErrors("pxcMeasureSingleFrameTpx3", rc, ENTER_ON);
   showFrameDual(frameData1, frameData2, mode);
   showFrameDual(frameTotEvent, frameToaITot, mode);
}
}
}}
}}


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcMeasureMultipleFrames
| Nam = pxcMeasureSingleFrameTpx2
| HeSym = ===
| HeSym = ===
| Sum = Performs a measurement of several frames to memory
| Sum = Performs a measurement of single frame and returns its data. This is only for Timepix2 detector and '''only if calibration is disabled'''
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned fameCount, double frameTime, unsigned trgStg
| DefP = unsigned deviceIndex, double frameTime, unsigned* frameData1, unsigned* frameData2, unsigned* size, unsigned trgStg
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameCount – numeber of frames to measure
| frameTime – time of the measurment in seconds
| frameTime – time of the measurment in seconds
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO
| frameData1 – pointer to buffer where data from the first counter (based on set operation mode) will be saved. For single detector chip, size is 65536
|
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single detector chip, size is 65536
|
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
: Only if Timepix2 calibration is disabled.
| War =
| War =
| Exa =void pxcMeasureMultipleFramesTpx3Test() { // =========================
| Exa =void pxcMeasureSingleFrameTpx2Test(unsigned di) { // di – device index ========
   int rc;                             // return codes
   int rc;                       // return codes
   const unsigned cSize = 65536;       // chip pixels count
   const unsigned cSize = 65536; // chip pixels count
   unsigned short frameTotEvent[cSize]; // frame data - event count
   unsigned frameData1[cSize];   // frame data - ToT data
   double frameToaITot[cSize];         // frame data - integrated time over threshold
   unsigned frameData2[cSize];   // frame data - ToA data
   double frameTime = 1.0;             // frame acquisition time
   double time = 1.0;             // frame acquisition time
  unsigned frameCount = 5;            // frame count
   unsigned size = cSize;         // buffer size and measured data size
   unsigned size = cSize;               // buffer size and measured data size
   int mode = PXC_TPX2_OPM_TOT10_TOA18;
 
   rc = pxcSetTimepix2Mode(di, mode);
   int mode = PXC_TPX3_OPM_EVENT_ITOT;
   printErrors("pxcSetTimepix2Mode", rc, ENTER_ON);
   rc = pxcSetTimepix3Mode(0, mode);
   rc = pxcMeasureSingleFrameTpx2(di, time, frameData1, frameData2, &size, PXC_TRG_NO);
   printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
  printErrors("pxcMeasureSingleFrameTpx2", rc, ENTER_ON);
 
  showFrameDual(frameData1, frameData2, mode);
   printf("measuring %d frames...\n", frameCount);
 
  pxcMeasureMultipleFrames(0, frameCount, frameTime, PXC_TRG_NO);
  printErrors("pxcMeasureMultipleFrames", rc, ENTER_ON);
  for (unsigned n=0; n<frameCount; n++) {
      rc = pxcGetMeasuredFrameTpx3(0, n, frameToaITot, frameTotEvent, &size);
      printErrors("pxcGetMeasuredFrameTpx3", rc, ENTER_ON);
      size = cSize;
      showFrameDual(frameTotEvent, frameToaITot, mode);
  }
}
}
}}
}}


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcMeasureMultipleFramesWithCallback
| Nam = pxcMeasureSingleCalibratedFrameTpx2
| HeSym = ===
| HeSym = ===
| Sum = Performs a measurement of several frames to memory. When each frame is measured, the supplied callback function is called and the userData parameter is passed as argument.
| Sum = Performs a measurement of single frame, calibrate ToT to energy and returns data. This is only for Timepix2 detector and '''only if calibration is enabled'''
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned fameCount, double frameTime, unsigned trgStg, FrameMeasuredCallback callback, intptr_t userData
| DefP = unsigned deviceIndex, double frameTime, double* frameData1, unsigned* frameData2, unsigned* size, unsigned trgStg
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameCount – numeber of frames to measure
| frameTime – time of the measurment in seconds
| frameTime – time of the measurment in seconds
| frameData1 – pointer to buffer where data from the first counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single detector chip, size is 65536
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
| callback – pointer to function of FrameMeasuredCallback type
| userData – pointer to some user object/memory that is passed in callback function
: See [[Binary_core_API#pxcRegisterAcqEvent|pxcRegisterAcqEvent]] for userData details
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
: Only if Timepix2 calibration is enabled.
| War =
| War =
| Exa =void pxcMeasureMultipleFramesWithCallbackTestTpx3(unsigned deviceIndex) { // ==============
| Exa =void pxcMeasureSingleCalibratedFrameTpx2Test(unsigned di) { // di – device index =====
int rc; // return codes
  int rc;                       // return codes
double frameTime = 1;
  const unsigned cSize = 65536;  // chip pixels count
unsigned frameCount = 5;
  double frameData1[cSize];      // frame data - ToT data = calibrated to energy
tMmfClbData usrData;
  unsigned frameData2[cSize];   // frame data - ToA data
usrData.di = deviceIndex;
  double time = 1.0;             // frame acquisition time
usrData.opm = PXC_TPX3_OPM_EVENT_ITOT;
  unsigned size = cSize;         // buffer size and measured data size
rc = pxcSetTimepix3Mode(deviceIndex, usrData.opm);
  int mode = PXC_TPX2_OPM_TOT10_TOA18;
printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
  rc = pxcSetTimepix2Mode(di, mode);
rc = pxcMeasureMultipleFramesWithCallback
  printErrors("pxcSetTimepix2Mode", rc, ENTER_ON);
(deviceIndex, frameCount, frameTime, PXC_TRG_NO, mmfCallback, (intptr_t)&usrData);
  rc = pxcMeasureSingleCalibratedFrameTpx2(di, time, frameData1, frameData2, &size, PXC_TRG_NO);
printErrors("pxcMeasureMultipleFramesWithCallback", rc, ENTER_ON);
  printErrors("pxcMeasureSingleCalibratedFrameTpx2", rc, ENTER_ON);
// Measure function ends, after all callbacks are serviced
  showFrameDual(frameData1, frameData2, mode);
}
}
}}


void mmfCallback(intptr_t acqCount, intptr_t userData) { // =================================
{{ApiBinaryItem
int rc; // return codes
| Nam = pxcMeasureMultipleFrames
const unsigned cSize = 65536; // chip pixels count
unsigned short frameTotEvent[cSize]; // frame data - event count
double frameToaITot[cSize]; // frame data - integrated time over threshold
unsigned size = cSize; // buffer size and measured data size
tMmfClbData usrData = *((tMmfClbData*)userData); // data transferred from start function
printf("mmfCallback acqCount=%d, di=%d\n", (unsigned)acqCount, usrData.di);
rc = pxcGetMeasuredFrameTpx3
(usrData.di, (unsigned)acqCount - 1, frameToaITot, frameTotEvent, &size);
printErrors("pxcGetMeasuredFrameTpx3", rc, ENTER_OFF); printf(", size=%d\n", size);
if (rc == 0) {
printf("Measured frame index %lu, ", (unsigned)acqCount - 1);
printf("count %d\n", pxcGetMeasuredFrameCount(usrData.di));
showFrameDual(frameTotEvent, frameToaITot, usrData.opm);
}
}
//The acqCount contains count of measured frames that are currently waiting in memory.
// You can use acqCount-1 as frame index to read.
// The userData is 64b number used to transfer some data from starting function to callback function.
// You can use it as data pointer like in this example, or simply as number with some overtyping.
typedef struct { // structure for userData, that is using in mmfCallback
unsigned di; // device index
int opm; // operation mode
} tMmfClbData;
}}
 
{{ApiBinaryItem
| Nam = pxcMeasureContinuous
| HeSym = ===
| HeSym = ===
| Sum = Performs an “endless” measurement of several frames to memory. The measurement is run until it’s aborted by pxcAbortMeasurement function. When each frame is measured, the supplied callback function is called and the userData parameter is passed as argument.
| Sum = Performs a measurement of several frames to memory
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned fameBufferSize, double frameTime, unsigned trgStg, FrameMeasuredCallback callback, intptr_t userData
| DefP = unsigned deviceIndex, unsigned fameCount, double frameTime, unsigned trgStg
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameBufferSize number of frames in circular buffer
| frameCount numeber of frames to measure
| frameTime – time of the measurment in seconds
| frameTime – time of the measurment in seconds
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO
| callback – pointer to function of FrameMeasuredCallback type
|
| userData – pointer to some user object/memory that is passed in callback function
|
: See [[Binary_core_API#pxcRegisterAcqEvent|pxcRegisterAcqEvent]] for userData details
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =''' '''
| Not =
* This function, differently to other multi-frame measurements, not waiting for process end. It simply start measurement and program continue next.
| War =
* You can set-up the callback by 2 ways:
| Exa =void pxcMeasureMultipleFramesTpx3Test() { // =========================
# Simply use pointer to callback function in the pxcMeasureContinuous function. After do it, the program must not leave the function in which pxcMeasureContinuous was used until the measurement is canceled.
  int rc;                             // return codes
# First use the '''pxcRegisterAcqEvent''' to set-up the callback, second use pxcMeasureContinuous without callback pointer or with NULL. Now it is possible to leave the superior function and measuring continue working independent. Afther cancel of the measurement, may be needed use the '''pxcUnregisterAcqEvent''' before other use of the Acq event.
  const unsigned cSize = 65536;        // chip pixels count
| War = Aborting measuremet from its callback (like as in commandline example bellow) can cause lags for tens of seconds. If the pxcAbortMeasurement called by other way (Button event in GUI for example), abort is fast.
  unsigned short frameTotEvent[cSize]; // frame data - event count
| Exa =void pxcMeasureContinuousTestTpx3(unsigned deviceIndex) { // ==============================
  double frameToaITot[cSize];          // frame data - integrated time over threshold
int rc; // return codes
  double frameTime = 1.0;             // frame acquisition time
double frameTime = 2;
  unsigned frameCount = 5;             // frame count
unsigned buffrerFrames = 3;
  unsigned size = cSize;               // buffer size and measured data size
tMmfClbData usrData;
usrData.di = deviceIndex;


usrData.cnt = 0; // num of frames to stop in callback (0 endless)
  int mode = PXC_TPX3_OPM_EVENT_ITOT;
usrData.opm = PXC_TPX3_OPM_EVENT_ITOT;
  rc = pxcSetTimepix3Mode(0, mode);
rc = pxcSetTimepix3Mode(deviceIndex, usrData.opm);
  printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);


// method 1 (single step):
  printf("measuring %d frames...\n", frameCount);
//rc = pxcMeasureContinuous (deviceIndex, buffrerFrames, frameTime, PXC_TRG_NO, mcCallback, (intptr_t)&usrData);
//printErrors("pxcMeasureContinuous", rc, ENTER_ON);
// method 2 (2 steps):
// register event
pxcRegisterAcqEvent(0, PXC_ACQEVENT_ACQ_FINISHED, mcCallback, (intptr_t)&usrData);
printErrors("pxcRegisterAcqEvent", rc, ENTER_ON);


// start continuous measuring (method 2, step 2)
  pxcMeasureMultipleFrames(0, frameCount, frameTime, PXC_TRG_NO);
rc = pxcMeasureContinuous(deviceIndex, buffrerFrames, frameTime);
  printErrors("pxcMeasureMultipleFrames", rc, ENTER_ON);
printErrors("pxcMeasureContinuous", rc, ENTER_ON);
  for (unsigned n=0; n<frameCount; n++) {
 
      rc = pxcGetMeasuredFrameTpx3(0, n, frameToaITot, frameTotEvent, &size);
printf("waiting for callbacks...\n");
      printErrors("pxcGetMeasuredFrameTpx3", rc, ENTER_ON);
getchar(); // waiting so that callbacks can come
      size = cSize;
printf("pxcMeasureContinuousTest: user end\n");
      showFrameDual(frameTotEvent, frameToaITot, mode);
  }
}
}
/*The callback function is some as used in pxcMeasureMultipleFramesWithCallback example, but usrData structure contains
}}
extra member, the cnt.This can be used to stop, whitch is additional in the callback: */


static unsigned cnt = 0;
{{ApiBinaryItem
cnt++;
| Nam = pxcMeasureMultipleFramesWithCallback
if (usrData.cnt > 0 && cnt >= usrData.cnt) {
// stop continuous measuring on user defined number of frames
printf("pxcAbortMeasurement...");
rc = pxcAbortMeasurement(usrData.di);
printErrors("pxcAbortMeasurement", rc, ENTER_ON);
printf("Press enter to exit the program.\n");
}
}}
 
{{ApiBinaryItem
| Nam = pxcAbortMeasurement
| HeSym = ===
| HeSym = ===
| Sum = Stopts the currently running measurement on the indexed device.
| Sum = Performs a measurement of several frames to memory. When each frame is measured, the supplied callback function is called and the userData parameter is passed as argument.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex
| DefP = unsigned deviceIndex, unsigned fameCount, double frameTime, unsigned trgStg, FrameMeasuredCallback callback, intptr_t userData
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
|
| frameCount – numeber of frames to measure
|
| frameTime – time of the measurment in seconds
|
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
|
| callback – pointer to function of FrameMeasuredCallback type
|
| userData – pointer to some user object/memory that is passed in callback function
: See [[Binary_core_API#pxcRegisterAcqEvent|pxcRegisterAcqEvent]] for userData details
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| Not =
| War = Aborting measuremet from its callback (like as in commandline example in pxcMeasureContinuous) can cause lags for tens of seconds. If the pxcAbortMeasurement called by other way (Button event in GUI for example), abort is fast.
| War =
| Exa =
| Exa =void pxcMeasureMultipleFramesWithCallbackTestTpx3(unsigned deviceIndex) { // ==============
}}
int rc; // return codes
double frameTime = 1;
unsigned frameCount = 5;
tMmfClbData usrData;
usrData.di = deviceIndex;
usrData.opm = PXC_TPX3_OPM_EVENT_ITOT;
rc = pxcSetTimepix3Mode(deviceIndex, usrData.opm);
printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
rc = pxcMeasureMultipleFramesWithCallback
(deviceIndex, frameCount, frameTime, PXC_TRG_NO, mmfCallback, (intptr_t)&usrData);
printErrors("pxcMeasureMultipleFramesWithCallback", rc, ENTER_ON);
// Measure function ends, after all callbacks are serviced
}


{{ApiBinaryItem
void mmfCallback(intptr_t acqCount, intptr_t userData) { // =================================
| Nam = pxcGetMeasuredFrameCount
int rc; // return codes
| HeSym = ===
const unsigned cSize = 65536; // chip pixels count
| Sum = Returns number of measured frames in memory. Usesful with pxcMeasureMultipleFrames.
unsigned short frameTotEvent[cSize]; // frame data - event count
| DefH = PXCAPI int
double frameToaITot[cSize]; // frame data - integrated time over threshold
| DefP = unsigned deviceIndex
unsigned size = cSize; // buffer size and measured data size
| deviceIndex – index of the device, starting from zero
tMmfClbData usrData = *((tMmfClbData*)userData); // data transferred from start function
|
printf("mmfCallback acqCount=%d, di=%d\n", (unsigned)acqCount, usrData.di);
|
rc = pxcGetMeasuredFrameTpx3
|
(usrData.di, (unsigned)acqCount - 1, frameToaITot, frameTotEvent, &size);
|
printErrors("pxcGetMeasuredFrameTpx3", rc, ENTER_OFF); printf(", size=%d\n", size);
|
if (rc == 0) {
|
printf("Measured frame index %lu, ", (unsigned)acqCount - 1);
|
printf("count %d\n", pxcGetMeasuredFrameCount(usrData.di));
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
showFrameDual(frameTotEvent, frameToaITot, usrData.opm);
| Not =
}
| War =
}
| Exa =
//The acqCount contains count of measured frames that are currently waiting in memory.
// You can use acqCount-1 as frame index to read.
// The userData is 64b number used to transfer some data from starting function to callback function.
// You can use it as data pointer like in this example, or simply as number with some overtyping.
typedef struct { // structure for userData, that is using in mmfCallback
unsigned di; // device index
int opm; // operation mode
} tMmfClbData;
}}
}}


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcSaveMeasuredFrame
| Nam = pxcMeasureContinuous
| HeSym = ===
| HeSym = ===
| Sum = Saves the measured frame to a file on the harddrive. This can be used instead of the pxcGetMeasuredFrame.
| Sum = Performs an “endless” measurement of several frames to memory. The measurement is run until it’s aborted by pxcAbortMeasurement function. When each frame is measured, the supplied callback function is called and the userData parameter is passed as argument.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned frameIndex, const char* filePath
| DefP = unsigned deviceIndex, unsigned fameBufferSize, double frameTime, unsigned trgStg, FrameMeasuredCallback callback, intptr_t userData
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameIndex index of the frame, starting from zero
| frameBufferSize number of frames in circular buffer
| filePath path to the file where frame will be saved
| frameTime – time of the measurment in seconds
|
| trgStg settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
|
| callback – pointer to function of FrameMeasuredCallback type
|
| userData – pointer to some user object/memory that is passed in callback function
: See [[Binary_core_API#pxcRegisterAcqEvent|pxcRegisterAcqEvent]] for userData details
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| Not =''' '''
| War =
* This function, differently to other multi-frame measurements, not waiting for process end. It simply start measurement and program continue next.
| Exa =void someCallback(intptr_t acqCount, intptr_t userData) { // ======================
* You can set-up the callback by 2 ways:
# Simply use pointer to callback function in the '''pxcMeasureContinuous''' function. After do it, the commandline program must not leave the function in which pxcMeasureContinuous was used until the measurement is canceled.
# First use the '''pxcRegisterAcqEvent''' to set-up the callback, second use pxcMeasureContinuous without callback pointer or with NULL. Now it is possible to leave the superior function and measuring continue working independent. Afther cancel of the measurement, may be needed use the '''pxcUnregisterAcqEvent''' before other use of the Acq event.
| War = Aborting measuremet from its callback (like as in commandline example bellow) can cause lags for tens of seconds. If the pxcAbortMeasurement called by other way (Button event in GUI for example), abort is fast.
| Exa =void pxcMeasureContinuousTestTpx3(unsigned deviceIndex) { // ==============================
int rc; // return codes
int rc; // return codes
tMmfClbData usrData = *((tMmfClbData*)userData);
double frameTime = 2;
rc = pxcSaveMeasuredFrame(usrData.di, (unsigned)acqCount - 1, "testFile.txt");
unsigned buffrerFrames = 3;
printErrors("pxcSaveMeasuredFrame-txt", rc, ENTER_ON);
tMmfClbData usrData;
rc = pxcSaveMeasuredFrame(usrData.di, (unsigned)acqCount - 1, "testFile.png");
usrData.di = deviceIndex;
printErrors("pxcSaveMeasuredFrame-txt", rc, ENTER_ON);
 
/* List of file extensions (format automatically detected by extension in filename):
usrData.cnt = 0; // num of frames to stop in callback (0 endless)
#define PX_EXT_ASCII_FRAME "txt"
usrData.opm = PXC_TPX3_OPM_EVENT_ITOT;
#define PX_EXT_BINARY_FRAME "pbf"
rc = pxcSetTimepix3Mode(deviceIndex, usrData.opm);
#define PX_EXT_MULTI_FRAME "pmf"
printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
#define PX_EXT_BINARY_MULTI_FRAME "bmf"
 
#define PX_EXT_COMP_TPXSTREAM "pcts"
// method 1 (single step):
#define PX_EXT_TPX3_PIXELS "t3p"
//rc = pxcMeasureContinuous (deviceIndex, buffrerFrames, frameTime, PXC_TRG_NO, mcCallback, (intptr_t)&usrData);
#define PX_EXT_TPX3_PIXELS_ASCII "t3pa"
//printErrors("pxcMeasureContinuous", rc, ENTER_ON);
#define PX_EXT_TPX3_RAW_DATA "t3r"
// method 2 (2 steps):
#define PX_EXT_FRAME_DESC "dsc"
// register event
#define PX_EXT_INDEX "idx"
pxcRegisterAcqEvent(0, PXC_ACQEVENT_ACQ_FINISHED, mcCallback, (intptr_t)&usrData);
#define PX_EXT_CLUSTER_LOG "clog"
printErrors("pxcRegisterAcqEvent", rc, ENTER_ON);
#define PX_EXT_PIXEL_LOG "plog"
 
#define PX_EXT_PNG "png"
// start continuous measuring (method 2, step 2)
#define PX_EXT_PIXET_RAW_DATA "prd"
rc = pxcMeasureContinuous(deviceIndex, buffrerFrames, frameTime);
    (t3.. formats not frames - cannot be used with pxcSaveMeasuredFrame) */
printErrors("pxcMeasureContinuous", rc, ENTER_ON);
 
printf("waiting for callbacks...\n");
getchar(); // waiting so that callbacks can come
printf("pxcMeasureContinuousTest: user end\n");
}
}
}}
/*The callback function is some as used in pxcMeasureMultipleFramesWithCallback example, but usrData structure contains
extra member, the cnt.This can be used to stop, whitch is additional in the callback: */


{{ApiBinaryItem
static unsigned cnt = 0;
| Nam = pxcGetMeasuredFrame
cnt++;
if (usrData.cnt > 0 && cnt >= usrData.cnt) {
// stop continuous measuring on user defined number of frames
printf("pxcAbortMeasurement...");
rc = pxcAbortMeasurement(usrData.di);
printErrors("pxcAbortMeasurement", rc, ENTER_ON);
printf("Press enter to exit the program.\n");
}
}}
 
{{ApiBinaryItem
| Nam = pxcAbortMeasurement
| HeSym = ===
| HeSym = ===
| Sum = Gets data of specified measured frame from memory
| Sum = Stopts the currently running measurement on the indexed device.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned fameIndex, unsigned short* frameData, unsigned* size
| DefP = unsigned deviceIndex
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameIndex – index of the frame, starting from zero
|
| frameData – pointer to buffer where data will be saved. For single chip detector size is 65536.
|
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable.
|
|
|
|
|
Line 2,161: Line 2,315:
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =This function have only one framebuffer. This is fully sufficient for single-output devices and modes. In combined modes (ToA+ToT, Event+IToT, dual threshold) only first data are available (ToA, Event, Threshold0). To take both outputs from the combined modes, it is necessary to use specialized functions for the given type of detector.
| Not =
| War =
| War = Aborting measuremet from its callback (like as in commandline example in pxcMeasureContinuous) can cause lags for tens of seconds. If the pxcAbortMeasurement called by other way (Button event in GUI for example), abort is fast.
| Exa =
| Exa =
}}
}}


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetMeasuredFrameTpx2
| Nam = pxcGetMeasuredFrameCount
| HeSym = ===
| HeSym = ===
| Sum = Gets data of specified measured frame from memory.
| Sum = Returns number of measured frames in memory. Usesful with pxcMeasureMultipleFrames.
:For Timepix2 chip only and only if '''calibration disabled'''.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned frameIndex, unsigned* frameData1, unsigned* frameData2, unsigned* size
| DefP = unsigned deviceIndex
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameIndex – index of the frame, starting from zero
|
| frameData1 – pointer to buffer where data from the first counter (based on set operationmode) will be saved. For single detector chip size is 65536
|
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single chip detector size is 65536
|
| size - pointer to varible with the size of the buffer. The actual size will be output to this variable
|
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
| Not =
:For Timepix2 chip only and only if '''calibration disabled'''.
| War =
| War =
| Exa =
| Exa =
Line 2,189: Line 2,341:


{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetMeasuredCalibratedFrameTpx2
| Nam = pxcSaveMeasuredFrame
| HeSym = ===
| HeSym = ===
| Sum = Gets data of specified measured frame with calibration from memory.
| Sum = Saves the measured frame to a file on the harddrive. This can be used instead of the pxcGetMeasuredFrame.
:For Timepix2 chip only and only if '''calibration enabled'''.
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned frameIndex, double* frameData1, unsigned* frameData2, unsigned* size
| DefP = unsigned deviceIndex, unsigned frameIndex, const char* filePath
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameIndex – index of the frame, starting from zero
| frameIndex – index of the frame, starting from zero
| frameData1 pointer to buffer where calibrated ToT->Energy data from the first counter (based on set operationmode) will be saved. For single detector chip size is 65536
| filePath path to the file where frame will be saved
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single chip detector size is 65536
|
| size - pointer to varible with the size of the buffer. The actual size will be output to this variable
|
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
| Not =
:For Timepix2 chip only and only if '''calibration enabled'''.
| War =
| War =
| Exa =
| Exa =void someCallback(intptr_t acqCount, intptr_t userData) { // ======================
}}
int rc; // return codes
 
tMmfClbData usrData = *((tMmfClbData*)userData);
rc = pxcSaveMeasuredFrame(usrData.di, (unsigned)acqCount - 1, "testFile.txt");
printErrors("pxcSaveMeasuredFrame-txt", rc, ENTER_ON);
rc = pxcSaveMeasuredFrame(usrData.di, (unsigned)acqCount - 1, "testFile.png");
printErrors("pxcSaveMeasuredFrame-txt", rc, ENTER_ON);
/* List of file extensions (format automatically detected by extension in filename):
#define PX_EXT_ASCII_FRAME "txt"
#define PX_EXT_BINARY_FRAME "pbf"
#define PX_EXT_MULTI_FRAME "pmf"
#define PX_EXT_BINARY_MULTI_FRAME "bmf"
#define PX_EXT_COMP_TPXSTREAM "pcts"
#define PX_EXT_TPX3_PIXELS "t3p"
#define PX_EXT_TPX3_PIXELS_ASCII "t3pa"
#define PX_EXT_TPX3_RAW_DATA "t3r"
#define PX_EXT_FRAME_DESC "dsc"
#define PX_EXT_INDEX "idx"
#define PX_EXT_CLUSTER_LOG "clog"
#define PX_EXT_PIXEL_LOG "plog"
#define PX_EXT_PNG "png"
#define PX_EXT_PIXET_RAW_DATA "prd"
    (t3.. formats not frames - cannot be used with pxcSaveMeasuredFrame) */
}
}}
 
{{ApiBinaryItem
{{ApiBinaryItem
| Nam = pxcGetMeasuredFrameTpx3
| Nam = pxcGetMeasuredFrame
| HeSym = ===
| HeSym = ===
| Sum = Gets data of specified measured frame from memory. For Timepix3 chip only.
| Sum = Gets data of specified measured frame from memory
| DefH = PXCAPI int
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned fameIndex, double* frameToaITot, unsigned short* frameToTEvent, unsigned* size
| DefP = unsigned deviceIndex, unsigned fameIndex, unsigned short* frameData, unsigned* size
| deviceIndex – index of the device, starting from zero
| deviceIndex – index of the device, starting from zero
| frameIndex – index of the frame, starting from zero
| frameIndex – index of the frame, starting from zero
| frameToaITot – pointer to buffer where data from ToA or iToT counter (based on set operation mode) will be saved. For single chip detector, size is 65536
| frameData – pointer to buffer where data will be saved. For single chip detector size is 65536.
| frameTotEvent – pointer to buffer where data from ToT or Event counter (based on set operation mode) will be saved. For single chip detector, size is 65536
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable.
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =This function have only one framebuffer. This is fully sufficient for single-output devices and modes. In combined modes (ToA+ToT, Event+IToT, dual threshold) only first data are available (ToA, Event, Threshold0). To take both outputs from the combined modes, it is necessary to use specialized functions for the given type of detector.
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcGetMeasuredFrameTpx2
| HeSym = ===
| Sum = Gets data of specified measured frame from memory.
:For Timepix2 chip only and only if '''calibration disabled'''.
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned frameIndex, unsigned* frameData1, unsigned* frameData2, unsigned* size
| deviceIndex – index of the device, starting from zero
| frameIndex – index of the frame, starting from zero
| frameData1 – pointer to buffer where data from the first counter (based on set operationmode) will be saved. For single detector chip size is 65536
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single chip detector size is 65536
| size - pointer to varible with the size of the buffer. The actual size will be output to this variable
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
:For Timepix2 chip only and only if '''calibration disabled'''.
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcGetMeasuredCalibratedFrameTpx2
| HeSym = ===
| Sum = Gets data of specified measured frame with calibration from memory.
:For Timepix2 chip only and only if '''calibration enabled'''.
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned frameIndex, double* frameData1, unsigned* frameData2, unsigned* size
| deviceIndex – index of the device, starting from zero
| frameIndex – index of the frame, starting from zero
| frameData1 – pointer to buffer where calibrated ToT->Energy data from the first counter (based on set operationmode) will be saved. For single detector chip size is 65536
| frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single chip detector size is 65536
| size - pointer to varible with the size of the buffer. The actual size will be output to this variable
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
:For Timepix2 chip only and only if '''calibration enabled'''.
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcGetMeasuredFrameTpx3
| HeSym = ===
| Sum = Gets data of specified measured frame from memory. For Timepix3 chip only.
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned fameIndex, double* frameToaITot, unsigned short* frameToTEvent, unsigned* size
| deviceIndex – index of the device, starting from zero
| frameIndex – index of the frame, starting from zero
| frameToaITot – pointer to buffer where data from ToA or iToT counter (based on set operation mode) will be saved. For single chip detector, size is 65536
| frameTotEvent – pointer to buffer where data from ToT or Event counter (based on set operation mode) will be saved. For single chip detector, size is 65536
| size – pointer to varible with the size of the buffer. The actual size will be output to this variable
|
|
|
|
Line 2,226: Line 2,463:
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Only for the Timepix3 devices, not usable on other Timepixes or Medipixes.
| Not = Only for the Timepix3 devices, not usable on other Timepixes or Medipixes.
| War =
| War =
| Exa =
| Exa =
}}
}}
 
= API data-driven measuring functions =
[[File:Cluster-example.png|right|300px|alt=Data-driven: Cluster example|Data-driven: Cluster example]]
The functions described in this chapter can be used if frame-based measurement is not good choice, in particle collision research, for example.<br>
<br>
'''Data-driven "frameless" in comparsion with frames:'''<br>
:;Advantages
::It is possible to continual measure for any length of time and repeated pixel hits are not lost.
:;Disadvantages
::Each pixel is transmitted as a separate packet, including its position. Therefore, this mode is significantly more demanding on the transmission speed.
<br>
Afther measurement start, data from every event is stored in the buffer. Pixels has structures (defined in the pxcapi.h):
<syntaxhighlight lang="C">
typedef struct _Tpx3Pixel {
double      toa;  // time of arrival [1 ns]
float        tot;  // time over threshold [25 ns] or energy [keV] if calibrated
unsigned int index; // index of pixel position
} Tpx3Pixel;
 
#pragma pack(push, 1)
typedef struct _RawTpx3Pixel {
    u32  index:      24;
    u64  toa:        64;
    byte overflow:  1;
    byte ftoa:      5;
    u16  tot:        10;
} RawTpx3Pixel;
#pragma pack(pop)
</syntaxhighlight>
 
See: [[The_RawTpx3Pixel_structure_in_memory|'''The RawTpx3Pixel structure in memory''']]<br>
 
<br>
The Pixet core has a circular buffer in memory. The default size is 100 MB. There are blocks in the buffer. The default block size is 66000 bytes. Incoming data is stored in a block. The “new data” event (that can start the callback or save the blockt to file) occurs if:
* The data size reaches the block size
* Some data is in block over the timeout (500 ms)
* The measurement ends
If you need to process data more often, you can set smaller block size. But if blocks are too small, data transfer speed can fall and some data can be lost. This can occurs if block size is less than approximately 5000 bytes (depends on computer speed and other circumstances).
 
;Example projects
:'''MiniPixTpx3-DataDriven''', commandline example – Set the parameters, use the callback and display the data, some auxiliary things and data convert. Save data to files. Without threads.
:'''AdvacamAPIexamples/Tpx3''', Windows GUI CLR app – All common functions including data-driven measurements. Using threads.
 
;Note
:Functions in this chapter is '''only for the Timepix3 devices''', not usable on other Timepixes or Medipixes.
 
{{ApiBinaryItem
| Nam = pxcMeasureTpx3DataDrivenMode
| HeSym = ==
| Sum = Performs a measurement with Timepix3 detector in Data Driven Mode (event by event mode, when stream of pixels is sent). '''Timepix3 only.'''
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, double measTime, const char* filename, unsigned trgStg, AcqEventFunc callback, intptr_t userData
| deviceIndex – index of the device, starting from zero
| measTime – the total time of the measurement in seconds. Use 0 for infinite.
| filename – output file name and path (extensions must end *.t3pa, *.trp, *.t3r)
| trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO
| callback – pointer to function of acqEventFunc type
| userData – pointer to some user object/memory that is passed in callback function
: See [[Binary_core_API#pxcRegisterAcqEvent|pxcRegisterAcqEvent]] for userData details
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa = int rc = pxcMeasureTpx3DataDrivenMode(0, 15, "testfile.t3pa");
// Measure for 15 seconds on device 0 with saving to the "testfile.t3pa" file
}}
;Example for online processing
<syntaxhighlight lang="C">
void timepix3DataDrivenGetPixelsTest(unsigned deviceIndex) { // ============================
int rc; // return codes
double measTime = 30;
int devIdx = deviceIndex; // transmitted over pointer for use in the callback function
 
// working with TOA, TOATOT, TOT_NOTOA, not working with EVENT_ITOT
rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_TOA);
printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
 
rc = pxcSetDeviceParameter(deviceIndex, PAR_DD_BLOCK_SIZE, 6000); // block [B]
printErrors("pxcSetDeviceParameter", rc, ENTER_OFF);
rc = pxcSetDeviceParameter(deviceIndex, PAR_DD_BUFF_SIZE, 100); // buffer [MB]
printf(", %d", rc);
rc = pxcSetDeviceParameter(deviceIndex, PAR_DCC_LEVEL, 80);
printErrors(",", rc, ENTER_ON); // data consistency check level (50-150) (*)
 
rc = pxcMeasureTpx3DataDrivenMode(deviceIndex, measTime, "", PXC_TRG_NO, onTpx3Data, (intptr_t)&devIdx);
printErrors("pxcMeasureTpx3DataDrivenMode", rc, ENTER_ON);
}
 
// * Data consistency check level : Detection level of ToA data inconsistency.
// If the chip is overloaded due too many partickes in time, clock can freezeand a ToA inconsistency occurrs.
// If it is detedted, measuring immediately stopand error “Acquisition failed(Data flow corrupted !!)“ occurrs.
// Level 50 is some like OFF, level 150 is highest sensitivity.
 
void onTpx3Data(intptr_t eventData, intptr_t userData) { // ================================
int deviceIndex = *((unsigned*)userData);
unsigned pixelCount = 0;
int rc; // return codes
 
rc = pxcGetMeasuredTpx3PixelsCount(deviceIndex, &pixelCount);
printErrors("getMeasuredTpx3PixelsCount", rc, ENTER_OFF);
printf(" PixelCount: %u\n", pixelCount);
 
auto result = new Tpx3Pixel[pixelCount];
rc = pxcGetMeasuredTpx3Pixels(deviceIndex, result, pixelCount);
printErrors("pxcGetMeasuredTpx3Pixels", rc, ENTER_ON);
 
dataUsingFunction(&result, pixelCount);
delete[] result;
}
</syntaxhighlight>
 
{{ApiBinaryItem
| Nam = pxcGetMeasuredTpx3PixelsCount
| HeSym = ==
| Sum = Gets the number of measured Timepix3 pixels in data driven mode. '''Timepix3 only.'''
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned*  pixelCount
| deviceIndex – index of the device, starting from zero
| pixelCount – pointer to output variable for number of pixels
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa = unsigned int cnt;
int rc = pxcGetMeasuredTpx3PixelsCount(0, &cnt);
if (rc==0) printf("%d pixels from device idx 0 are waiting in memory\n", cnt);
else printf("pxcGetMeasuredTpx3PixelsCount failed, code %d\n", rc);
}}
 
{{ApiBinaryItem
| Nam = pxcGetMeasuredTpx3Pixels
| HeSym = ==
| Sum = Gets the measured Timepix3 pixels data. '''Timepix3 only.'''
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, Tpx3Pixel* pixels, unsigned pixelCount
| deviceIndex – index of the device, starting from zero
| pixels – pointer to array of Tpx3Pixels that will be filled with measured pixels
: ToT in output data are ToT in 25ns ticks or energy in keVs, depending on Timepix3CalibrationEnabled
: See pxcSetTimepix3CalibrationEnabled, pxcIsTimepix3CalibrationEnabled
| pixelCount – size of the supplied array as number of pixels
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcGetMeasuredRawTpx3Pixels
| HeSym = ==
| Sum = Gets the measured Timepix3 pixels data in raw format. '''Timepix3 only.'''
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, RawTpx3Pixel* pixels, unsigned pixelCount
| deviceIndex – index of the device, starting from zero
| pixels – buffer where pixels will be saved
| pixelCount – size of pixels buffer (number of pixels to save)
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not = Use the pxcGetMeasuredRawTpx3Pixels only in special, exceptional cases.
| War = See: [[The_RawTpx3Pixel_structure_in_memory|The RawTpx3Pixel structure in memory]]
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcCalibrateTpx3PixelsAndFilter
| HeSym = ==
| Sum =  Calibrate the pixel data and filter them by energy range
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, Tpx3Pixel* pixels, unsigned* pixelCount, double minEnergy, double maxEnergy
| deviceIndex – index of the device, starting from zero
| pixels – pointer to array of Tpx3Pixels that will be filled with measured pixels
| pixelCount – size of pixels buffer (number of pixels). It will be filled with the number of pixel remaining after filtration
| minEnergy – minimal allowed energy of each pixel
| maxEnergy – maximal allowed energy of each pixel
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
= API frame-data processing functions =
{|
|+
|-
| [[File:Beam-hardening-bh2c.png|left|frame|alt=Left: raw image, mid: After beam hardening correction, right: after BHC and bad pixels interpolation|Left: raw image, mid: After beam hardening correction, right: after BHC and bad pixels interpolation]]
|}
 
== Interpolating of bad pixels ==
<br>
{{ApiBinaryItem
| Nam = pxcInterpolateBadPixels
| HeSym = ===
| Sum = Interpolates bad pixels in the image. Uses badPixelsMatrix as bad pixels (badPixel = 1, good = 0)
| DefH = PXCAPI int
| DefP = unsigned char* badPixelsMatrix, double* data, unsigned width, unsigned height
| badPixelMatrix – matrix of the bad pixels
| data – data to be interpolated
| width – width of the image
| height – height of the image
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcGetDeviceBadPixelMatrix
| HeSym = ===
| Sum = Gets the devices's matrix of bad pixels (bad = 1, good = 0). Bad pixels are pixels that are masked.
| DefH = PXCAPI int
| DefP = unsigned deviceIndex, unsigned* badPixelMatrix, unsigned size
| deviceIndex – index of the device, starting from zero
| badPixelMatrix – output data buffer where bad pixel matrix will be saved
| size – size of the data - number of pixels (width * height)
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
== Beam hardening correction ==
The functions described in this chapter can be used to compensate the beam hardening effect, bad pixels and chip sensitivity uneven to get the data with true thickness of measured material.<br>
<br>
First step is adding set of the reference images (masks). Dirrect beam (or beam with filter that will be used in all the process) and flat plates with different thicknesses, optimally in whole range that you want measuring. Use the '''pxcAddBHMask'''. Reference images contains unsigned 32bit pixels. To create the reference pictures, recommended fold more acquired images to achieve pixel values aproximatelly tens of thousands or more (50,000 is good start). Don’t forget corectly set their thickness.<br>
<br>
If 2 or more reference images have been added, it is possible to determine which pixels are not usable. Check this using the '''pxcGetBHBadPixelMatrix''' function. If there are too many of these pixels, the '''pxcApplyBHCorrection''' function may lose accuracy and the '''pxcInterpolateBadPixels''' function will not work. In this case you can check:
* If the set-up is correct (condition of the reference plates; Is the whole area of the chip good irradiated and covered by the reference plates? Is there an obstacle in the beam?)
* If there is too much contrast between the references - a common problem, especially between the free beam and the first reference plate - you can use a filter throughout the process
* If some areas have too low values with high noise - increase the number of integrated frames, beam intensity, or acquisition time
* If exist areas with overexposition – decrease the time or beam intensity
* If the instability of the CdTe chip has manifested itself - increase the time by integrating the reference images
* If using CdTe and measuring start too soon afther chip init
* Try use other beam energy
After add sufficient number of reference images, you can measure image of the sample and use the '''pxcApplyBHCorrection''' function. Output is array of double, in units from reference thicknesses.<br>
<br>
Now you can use the '''pxcGetDeviceAndBHBadPixelMatrix''' to get array of bad and other unusable pixels. Use this data with the '''pxcInterpolateBadPixels'''. If it doesn't work, you can use only device bad pixels from the '''pxcGetDeviceBadPixelMatrix''' function.<br>
<br>
;Example projects
: '''MiniPixTpx3-Thickness-auto''' – Acquision time auto tuning for easy first experiments.
:: Interactive control in console, text histograms and preview of images. But the code is relatively complex.
: '''MiniPixTpx3-Thickness-bath''' – Bath process, using text config file.
:: Simple code, but you need to set usable acquisition times.
 
{{ApiBinaryItem
| Nam = pxcAddBHMask
| HeSym = ===
| Sum = Adds a new mask (frame) for Beam-Hardening calibration.
| DefH = PXCAPI int
| DefP = unsigned* data, unsigned size, double frameTime, double thickness
| data – data of the frame tat will be used as BH mask
| size – size of the data - number of pixels (width * height)
| frameTime – acquisition time of the frame in seconds
| thickness – thickness of the measured data
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcBHMaskCount
| HeSym = ===
| Sum = Returns number of inserted Beam-Hardening masks (frames)
| DefH = PXCAPI int
| DefP =
|
|
|
|
|
|
|
|
| Ret = Number of masks if successful, otherwise the return value is a PXCERR_XXX code
| Not =
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcRemoveBHMask
| HeSym = ===
| Sum = Removes Beam-Hardening mask (frame)
| DefH = PXCAPI int
| DefP = int index
| index – index of the mask to remove
|
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcApplyBHCorrection
| HeSym = ===
| Sum = Applies the Beam-Hardening correction to supplied frame
| DefH = PXCAPI int
| DefP = unsigned* inData, unsigned size, double frameTime, double* outData
| inData – data of the frame that will be corrected
| size – size of the data - number of pixels (width * height)
| frameTime – acquisition time of the measured frame in seconds
| outData – output data buffer where corrected data will be saved
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcGetBHBadPixelMatrix
| HeSym = ===
| Sum = Gets the bad pixel matrix from Beam Hardening correction - pixels that cannot be corrected. (bad pixel = 1, good = 0). Must be called after all BH masks are added.
| DefH = PXCAPI int
| DefP = unsigned* badPixelMatrix, unsigned size
| badPixelMatrix – output data buffer where bad pixel matrix will be saved
| size – size of the data - number of pixels (width * height)
|
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
{{ApiBinaryItem
| Nam = pxcGetDeviceAndBHBadPixelMatrix
| HeSym = ===
| Sum = Gets the combined bad pixel matrix from the device and BeamHardening (badpixel = 1, good = 0).
| DefH = PXCAPI int
| DefP = unsigned devIndex, unsigned* badPixelMatrix, unsigned size
| deviceIndex – index of the device, starting from zero
| badPixelMatrix – output data buffer where bad pixel matrix will be saved
| size – size of the data - number of pixels (width * height)
|
|
|
|
|
| Ret = 0 if successful, otherwise the return value is a PXCERR_XXX code.
| Not =
| War =
| Exa =
}}
 
'''See: [[Binary_core_API#pxcGetDeviceBadPixelMatrix|pxcGetDeviceBadPixelMatrix]], [[Binary_core_API#pxcInterpolateBadPixels|pxcInterpolateBadPixels]]'''
 
<br>
=== Example ===
----
'''See:'''
* [[Beam_hardening_correction:_Bath_example|Beam hardening correction: Bath example]]
<br>
<br>
 
=== Some images ===
----
{|
|+
|-
|
[[File:CdTe vs Si.png|none|alt=CdTe vs Si|CdTe vs Si]]
|| '''1. CdTe 2 mm (left) vs Si 0,3 mm (right)'''<br>
<br>
'''CdTe advantages:''' More sensitive, orders of magnitude shorter acquisition times or lower beam intensities. Have lower energy consumption and and it less warming.<br>
imgs:<br>
CdTe: integrated 3.43 sec (25,6 ms subframes)<br>
Si: integrated 27.7 sec (625 ms subframes)
|}
----
{|
|+
|-
|
[[File:CdTe artefacts.png|none|alt=CdTe artefacts|CdTe artefacts]]
|| '''CdTe disadvantages:''' Uneven distribution of chip sensitivity. Slow instability can cause the need for a long total measurement time.<br>
Specialy thick chips have a easily visible image distortion. Afther start-up, CdTe contains lot of free charges, they can cause problems duringearly measurements (use '''pxcDoSensorRefresh''').<br>
<br>
Si and CdTe have opposite bilas polarity. This can be used for type detection.
|}
 
----
{|
|+
|-
|
[[File:Beam hardening setup Bh1a.jpg|thumb|none|alt=beam hardening experimental setup|beam hardening experimental setup]]
|| '''2. The beam hardening experimental setup'''<br>
1 – The sensor<br>
2 – Pb shielding of electronics (for sure, large intensities were tested in this experiment)<br>
3 – several thin sheets, a total of 0.3 mm to reduce free beam / first ref. plate contrast<br>
4 – 0.6 mm reference plates<br>
|}
----
{|
|+
|-
|
[[File:Beam hardening Bh1c.png|none]]
|| [[File:Beam hardening Bh2c.png|none]]
|| '''3. Test images'''<br>
Left is Fe bearing, used reference plates and the setup from img. 2<br>
<br>
Right is Al plates, 3 and 8 mm, reference plates was several 3mm sheets<br>
<br>
Up – original images<br>
Mid – afther pxcApplyBHCorrection<br>
Down – mid afther pxcInterpolateBadPixels <br>
(range in all images auto-resized to grayscale 0-255)
|}
----
{|
|+
|-
|
[[File:Beam_hardening_Bh2a.jpg|thumb|none]]
|| '''4. The Al plates experimental setup'''<br>
<br>
1 – Cooler - Si chip used<br>
2 – The Minipix<br>
3 – Imaged aluminium plates<br>
4 – Thin Al sheet to reduce free beam / first ref. plate contrast
|}
 
= The synchronizing =
{|
|+
|-
|
[[File:The synchronizing-Widepix.jpg|200px|none]]
|| Sometimes it is necessary to synchronized with an external event. Or some instruments, Widepix-L for example, can be organized as set of more than 1 device in 1 box and more than 1 data cable go out. If you want start acquisition on whole instrument at exactly the same time, must use synchronization by the hardware trigger.
|}
 
== Synchronizing basics ==
The acquisition functions have the TrgStg parameter. The 4th argument "trigger settings" of the pxcMeasureTpx3DataDrivenMode(), for example. This have options:<br>
<br>
{|
|+
|-
| '''PXC_TRG_NO''' || No sync. Normally start immediatelly and stop after acqTime.
|-
| '''PXC_TRG_HWSTART''' || Slave wait and start the acq. on HW signal, master can wait for slave ready.
|-
| '''PXC_TRG_HWSTOP'''<br>&nbsp; || Start the acq. immediatelly and stop on HW signal or after acqTime.<br>(Available only in specific devices, see sync. manual.)
|-
| '''PXC_TRG_HWSTARTSTOP'''<br>&nbsp; || Wait and start the acq. on HW signal and stop at next HW signal.<br>(Available only in specific devices, see sync. manual.)
|-
| '''PXC_TRG_SWSTART''' || Wait and start the acq. on SW signal = [[Binary_core_API#pxcDoSoftwareTrigger|pxcDoSoftwareTrigger()]].
|}
<br>
Additionally, you must use the named parameters. You can read if the device is ready, is it master, etc and write some parameters. Details depends on the device type. Some devices allow reset the ToA counter without restart acquisition or start acquisition without reset the ToA counter.<br>
<br>
'''See:''' [[#Parameter_Get/Set_functions_(using_text_paramName)|Parameter Get/Set functions (using text paramName)]]
 
== Synchronizing with an external source ==
Sync with the external source can depends on the device type. See the synchronization manual of your device type for hardware details.<br>
<br>
'''Example:''' Way to use the external HW sync with the Advapix-Tpx3<br>
 
1. Set some synchronization parameters: "TrgTimestamp", "TrgT0SyncReset", "TrgOutLevel", "TrgOutEnable" using function to write the named parameters: pxcSetDeviceParameter.<br>
2. Read some synchronization parameters: "TrgReady", "IsMaster" using the pxcGetDeviceParameter.<br>
3. Start the pxcMeasure... with some PXC_TRG_HW...<br>
4. Apply the sync signal to the input.<br>
 
== Synchronizing in multi-device instruments ==
(This text is primary about the WIdepix-L with 2 ethernet cables, if using other device, see the Synchronization manual of your device)<br>
<br>
'''Decision which device is master'''<br>
<syntaxhighlight lang="C">
    isMaster = pxcGetDeviceParameter(devIdx, "TriggerMaster");
</syntaxhighlight>
 
Output is 0 for slave, 1 for master or single, <0 if the device not supports param name/type.<br>
; Note
: Some devices has '''IsMaster''' and some other has '''TriggerMaster'''.
: Some devices has output '''bool''' (read as int 0/1) and some other has '''string''' (read as char[] "Yes"/"No")
: In universal software, expect all 4 combinations to exist.
 
<br>
'''Master Setup'''
# Set the parameter TriggerStg = 0
# Set the parameter TriggerWaitForReady = 1
# Set the parameter TriggerOutLevel = 1
 
'''Slave setup'''
# Set the parameter TriggerStg = 2
# Set the parameter TriggerWaitForReady = 1
 
'''The measurement'''<br>
This can be simple if the continuous acquisition is used: This API function starts in separate thread:<br>
 
<syntaxhighlight lang="C">
rcs = pxcMeasureContinuous(slvIdx, bufCnt, acqTime, PXC_TRG_HWSTART, callback, (intptr_t)slvIdx);
rcm = pxcMeasureContinuous(masIdx, bufCnt, acqTime, PXC_TRG_HWSTART, callback, (intptr_t)masIdx);
errorToList("pxcMeasureContinuous s,m", rcs, rcm);
</syntaxhighlight>
 
But if using other acq. functions, you must start slave acq. in separate thread manually.<br>
(see the Visual Studio example “Mpx3-2-sync”)<br>
 
'''Note Widepix-L'''
: If the acquisition time is long, approximately from 100 ms, the run is irregular and there may be long pauses (1 to 5 * acqTime) between acquisitions. This can be suppressed if master acqTime is approximately over 10 % longer.
 
'''Widepix-L: The TriggerStg and TriggerOutLevel are linked in the following way:'''
 
{| class="wikitable"
|-
! Function !! Master TriggerStg !! Master TriggerOutLevel !! Slave TriggerStg !! Slave TriggerOutLevel
|-
| Sync 1:1 || 0 || 0 || 3 || X
|-
| Alternating sync || 0 || 0 || 2 || X
|-
| Alternating sync || 0 || 1 || 3 || X
|-
| Sync 1:1 || 0 || 1 || 2 || X
|}
X - the value doesn't matter
 
== Synchronizing a multi-device with an external source ==
 
Set the device normally for synchronizing in multi-device (See chapter above for details), but in the master settings set the TriggerStg alias TrgStg to 2 or 3 by the used edge of trigger signal. Be carefull if using 0 or 1.
 
{| class="wikitable"
|+ Example setting for double-device external sync on rising edge
|-
! Function !! Master TriggerStg !! Master TriggerOutLevel !! Slave TriggerStg !! Slave TriggerOutLevel
|-
| Ext and 1:1 || 2 || 1 || 2 || X
|}
X - the value doesn't matter
 
== Multi-device synchronizing examples ==
These samples are derived from the Mpx3 project from the AdvacamAPIexamples collection.<br>
<br>
Global variables of the example:
<syntaxhighlight line lang=C>
unsigned *collectDevFrameD1 = NULL, *collectDevFrameD2 = NULL; // collected devs all frame data
unsigned collectDevFramePxCnt = 0; // collectDevFrameDx size = devWid * devHei * devCnt * collectImgCnt
unsigned devcollectDevsIdx[256]; // list of devs to collect imgs
int collectDevsCnt = -1; // count of devs to be collected (>0 to enable)
int collectDevsMasterIdx = -1; // index of master position in devcollectDevsIdx[]
unsigned collectDevWidth = -1, collectDevHeight = -1; // size of collected image
unsigned collectImgsMax = 0; // =textColImgsMax->Text; vertical count of images to be collected
int collectDevCntCallbacks, collectDevCntOK, collectDevCntFail; // callbacks img collect status
 
double acqTime = 1.0; // time for acq. functions
int frameCount = 0; // frames count for pxcMeasureMultipleFrames
// or cilcular buffer frames count for pxcMeasureContinuous
int deviceMaxIdx = -1; // maximal connected dev idx (count-1)
int deviceIndex = -1; // index of the single device to be used
int frameLastIndex = -1; // index of the frame that was viewed and for saving
</syntaxhighlight>
 
=== Preparing setup for synchronized Mpx3 multi-device example ===
Decision if the dev is master (all dev types with internal synchronization):
<syntaxhighlight lang="cpp">
int isDevMaster(unsigned di) {
int rc = pxcGetDeviceParameter(di, "TriggerMaster");
if (rc == 0 || rc == 1) return rc;
 
rc = pxcGetDeviceParameter(di, "IsMaster");
if (rc == 0 || rc == 1) return rc;
 
char val[] = "  ";
rc = pxcGetDeviceParameterString(di, "TriggerMaster", val, 4);
if (rc!=0) pxcGetDeviceParameterString(di, "IsMaster", val, 4);
if (rc == 0) {
if (strcmp(val, "Yes") == 0) return 1;
else if (strcmp(val, "No") == 0) return 0;
else return MY_ERR_CODE;
}
return rc;
}
</syntaxhighlight>
<br>
Setup devices, the textCollectDevsOrd contains device indexes order string, like as "102", primary used to joining images side by side in the desired order (Tested with Widepix, ethernet or USB):
<syntaxhighlight lang="cpp">
collectDevsCnt = textCollectDevsOrd->Text->Length;
int trgMastCnt = 0;
for (int n = 0; n < collectDevsCnt; n++) {
devcollectDevsIdx[n] = Convert::ToInt32(textCollectDevsOrd->Text[n] - '0');
if (devcollectDevsIdx[n] > deviceMaxIdx) { // deviceMaxIdx = global, set after init pxcore
collectDevsCnt = -1;
msgToList(String::Format("Collect devs: devIdx out of range {0}", devcollectDevsIdx[n]));
}
 
int isMast = isDevMaster(devcollectDevsIdx[n]);
if (isMast < 0) {
errorToList("pxcGetDeviceParameter TriggerMaster", isMast);
isMast = 0;
}
if (isMast == 1) {
trgMastCnt++;
collectDevsMasterIdx = n;
rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerStg", 0);
errorToList("pxcSetDeviceParameter TriggerStg", rc);
rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerWaitForReady", 1);
errorToList("pxcSetDeviceParameter TriggerWaitForReady", rc);
rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerOutLevel", 1);
errorToList("pxcSetDeviceParameter TriggerOutLevel", rc);
} else {
rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerStg", 2);
errorToList("pxcSetDeviceParameter TriggerStg", rc);
rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerWaitForReady", 1);
errorToList("pxcSetDeviceParameter TriggerWaitForReady", rc);
rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerOutLevel", 0);
errorToList("pxcSetDeviceParameter TriggerOutLevel", rc);
}
}
if (trgMastCnt != 1 || collectDevsCnt < 2) {
msgToList("Err: 2 or more devs incl. 1 TriggerMaster needed for collect");
collectDevsCnt = -1;
collectDevsMasterIdx = -1;
} else {
msgToList(String::Format("Collect devs setup complete. Master idx/devIdx:{0}/{1}",
collectDevsMasterIdx, devcollectDevsIdx[collectDevsMasterIdx]));
}
</syntaxhighlight>
 
=== Starting acquisitions for synchronized Mpx3 multi-device example ===
This section using the callbacks to get actual data. The userData parameter is used to inform the callback function about source device index in the devcollectDevsIdx[]. Based on the index into devcollectDevsIdx[] and the frame index, a place in the buffer is selected and read from the device is called.<br>
<br>
Setup and start the synchronized measurement with using continuous acquisition.<br>
Note: Continuous mode is not usable with TDI.<br>
(Tested with Widepix, ethernet or USB):
<syntaxhighlight lang="cpp">
rc = initMeasParams("Continuous acq. with callback test", true, true); // set-up buffers, operation mode and other measurement settings
if (rc!=0) return;
 
if (collectDevsCnt > 0) {
for (int n = 0; n <= collectDevsCnt; n++) {
if (n == collectDevsMasterIdx) continue; // skip the master and start it at end
int di = devcollectDevsIdx[n];
if (n == collectDevsCnt) di = devcollectDevsIdx[collectDevsMasterIdx];
 
rc = pxcMeasureContinuous(di, frameCount, acqTime, PXC_TRG_HWSTART, clbContinuousAcq,
(n < collectDevsCnt) ? n : collectDevsMasterIdx);
msgToList(String::Format("n:{0} di:{1} pxcMeasureContinuous {2} {3}",
n, di, rc, (rc==0)? "OK": "failed"));
if (rc != 0) return;
}
} else {
// pxcMeasureContinuous(unsigned deviceIndex, unsigned frameBufferSize, double frameTime, unsigned trgStg = PXC_TRG_NO, FrameMeasuredCallback callback = 0, intptr_t userData = 0);
rc = pxcMeasureContinuous(deviceIndex, frameCount, acqTime, PXC_TRG_NO, clbContinuousAcq, NULL);
errorToList("pxcMeasureContinuous", rc);
}
</syntaxhighlight>
<br>
 
Setup and start the synchronized measurement with using multi-acquisition.<br>
A bit more complicated, but works with TDI as well.<br>
(Tested with Widepix, ethernet or USB):
<syntaxhighlight line lang=C>
int rc;
DWORD dwThrID;
HANDLE h;
 
int rc = initMeasParams("More frames with callback test", true, true); // set-up buffers, operation mode and other measurement settings
if (rc!=0) return;
if (collectDevsCnt>0) {
for (int n = 0; n <= collectDevsCnt; n++) {
if (n == collectDevsMasterIdx) continue; // skip master and start it at end
int di = devcollectDevsIdx[n];
if (n == collectDevsCnt) di = devcollectDevsIdx[collectDevsMasterIdx];
sMeasureMultFrsCallbackPars* thrData = new sMeasureMultFrsCallbackPars(di, frameCount, acqTime, PXC_TRG_HWSTART, clbFramesWC,
(n < collectDevsCnt) ? n : collectDevsMasterIdx);
h = CreateThread(NULL, 0, MeasureMultFrsCallbackThrFn, (void*)thrData, 0, &dwThrID);
msgToList(String::Format("n:{0} di:{1} CreateThread {2} OK", n, di, (int)dwThrID));
if (h == NULL) {
msgToList(String::Format("n:{0} di:{1} CreateThread {2} failed", n, di, (int)dwThrID));
return;
}
}
} else {
sMeasureMultFrsCallbackPars* thrData = new sMeasureMultFrsCallbackPars(deviceIndex, frameCount, acqTime, PXC_TRG_NO, clbFramesWC, NULL);
h = CreateThread(NULL, 0, MeasureMultFrsCallbackThrFn, (void*)thrData, 0, &dwThrID);
msgToList("pxcMeasureMultipleFramesWithCallback - thread " + System::Convert::ToString((int)dwThrID));
if (h == NULL) return;
}
</syntaxhighlight>
 
=== Callbacks for synchronized Mpx3 multi-device example ===
Collecting the image data, called from callbacks (Tested with Widepix, ethernet or USB):
<syntaxhighlight line lang=C>
// idx of devcollectDevsIdx, frame idx
void collectDevImgs(unsigned ndi, unsigned fIdx) {
int rc;
size_t adrAdd = static_cast<size_t>(devPixels * (ndi + (fIdx % collectImgsMax) * collectDevsCnt));
unsigned *cd1 = collectDevFrameD1 + adrAdd;
unsigned *cd2 = collectDevFrameD2 + adrAdd;
unsigned bs = collectDevFramePxCnt - adrAdd;
 
if (bs < 0x80000000) {
rc = pxcGetMeasuredFrameMpx3(devcollectDevsIdx[ndi], fIdx, cd1, cd2, &bs);
} else rc = MY_ERROR_CODE;
 
collectDevCntCallbacks++;
if (rc == 0) {
collectDevCntOK++;
} else {
collectDevCntFail++;
}
}
</syntaxhighlight>
<br>
 
The callbacks:
<syntaxhighlight line lang=C>
// callback function for "frames with callback"
void clbFramesWC(intptr_t acqCount, intptr_t userData) {
frameLastIndex = acqCount-1;
clbCnt++;
if (collectDevsCnt > 0) {
collectDevImgs((unsigned)userData, frameLastIndex);
return;
}
}
 
// callback function for continuous acquisition
void clbContinuousAcq(intptr_t acqCount, intptr_t userData) {
if (acqCount<0) {
clbError = acqCount;
return;
}
frameLastDevIdx = (int)userData;
clbCnt++;
 
if (acqCount<frameCount) {
frameLastIndex = acqCount - 1;
} else {
if (++frameLastIndex>=acqCount) frameLastIndex = 0;
}
 
if (collectDevsCnt > 0) {
collectDevImgs((unsigned)userData, frameLastIndex);
return;
}
}
</syntaxhighlight>
<br>
 
<syntaxhighlight line lang=C>
</syntaxhighlight>
 
=== Rearranging measured data to complete image ===
When all measurements are complete, the data is arranged in memory so that each frame from each device occupies a contiguous area. In order for images to be connected when displaying, each line of the resulting image must contain lines from individual neighboring devices.
 
{| class="wikitable"
|+ Rearranging data from two adjacent sub-devices and three images
|-
! Measured data in memory !! style="width:50px;" rowspan=7 |  !! colspan=2| Rearranged data in memory
|-
| style="height:30px; width:400px; text-align:center;" |device 0 / frame 0
| style="height:60px; width:200px; text-align:center;" rowspan=2 |device 0 / frame 0
| style="height:60px; width:200px; text-align:center;" rowspan=2 |device 1 / frame 0
|-
| style="height:30px; width:400px; text-align:center;" |device 1 / frame 0
|-
| style="height:30px; width:400px; text-align:center;" |device 0 / frame 1
| style="height:60px; width:200px; text-align:center;" rowspan=2 |device 0 / frame 1
| style="height:60px; width:200px; text-align:center;" rowspan=2 |device 1 / frame 1
|-
| style="height:30px; width:400px; text-align:center;" |device 1 / frame 1
|-
| style="height:30px; width:400px; text-align:center;" |device 0 / frame 2
| style="height:60px; width:200px; text-align:center;" rowspan=2 |device 0 / frame 2
| style="height:60px; width:200px; text-align:center;" rowspan=2 |device 1 / frame 2
|-
| style="height:30px; width:400px; text-align:center;" |device 1 / frame 2
|}
 
<syntaxhighlight line="" lang="C">
compiledFr1 = (unsigned*)malloc(collectDevFramePxCnt * sizeof(unsigned));
//compiledFr2 = (unsigned*)malloc(collectDevFramePxCnt * sizeof(unsigned));
 
compiledImgData1 = (int*)malloc(collectDevFramePxCnt * sizeof(int));
//compiledImgData2 = (int*)malloc(collectDevFramePxCnt * sizeof(int));
 
if (!compiledFr1 || !compiledImgData1) {
msgToList("viewCollectedDevsFrs: Memory allocation failed");
 
if (compiledFr1) free(compiledFr1);
if (compiledFr2) free(compiledFr2);
if (compiledImgData1) free(compiledImgData1);
if (compiledImgData2) free(compiledImgData2);
return;
}
 
size_t adrAddIn = 0, adrAddOut = 0;
// adrAdd = devPixels * ndi  +  collectDevsCnt * devPixels * (fIdx % collectImgsMax);
for (size_t fi = 0; fi < collectImgsMax; fi++) { // frames
for (size_t lin = 0; lin < collectDevHeight; lin++) { // lines of single frame
for (size_t ndi = 0; ndi < collectDevsCnt; ndi++) { // subdevices idxs in collectDevsCnt
adrAddIn = collectDevsCnt * devPixels * fi + devPixels * ndi + devWidth * lin;
 
if (checkCollectReverseLines->Checked) {
for (size_t x = 0; x < devWidth; x++) {
(compiledFr1 + adrAddOut)[x] = (collectDevFrameD1 + adrAddIn)[devWidth - x];
//(compiledFr2 + adrAddOut)[x] = (collectDevFrameD2 + adrAddIn)[devWidth - x];
}
} else {
memcpy(compiledFr1 + adrAddOut, collectDevFrameD1 + adrAddIn, devWidth * sizeof(unsigned));
//memcpy(compiledFr2 + adrAddOut, collectDevFrameD2 + adrAddIn, devWidth * sizeof(unsigned));
}
adrAddOut += (size_t)devWidth;
}
}
}


= API data-driven measuring functions =
colorizeData(compiledFr1, compiledImgData1, collectDevFramePxCnt);
[[File:Cluster-example.png|right|300px|alt=Data-driven: Cluster example|Data-driven: Cluster example]]
Bitmap^ bmp1c = gcnew Bitmap(collectDevWidth, collectDevHeight * collectImgsMax, collectDevWidth * 4, System::Drawing::Imaging::PixelFormat::Format32bppRgb, (IntPtr)compiledImgData1);
The functions described in this chapter can be used if frame-based measurement is not good choice, in particle collision research, for example.<br>
pictureBox3->SizeMode = PictureBoxSizeMode::StretchImage;
<br>
pictureBox3->Image = bmp1c;
'''Data-driven "frameless" in comparsion with frames:'''<br>
:;Advantages
::It is possible to continual measure for any length of time and repeated pixel hits are not lost.
:;Disadvantages
::Each pixel is transmitted as a separate packet, including its position. Therefore, this mode is significantly more demanding on the transmission speed.
<br>
Afther measurement start, data from every event is stored in the buffer. Pixels have structure (defined in the pxcapi.h):
<syntaxhighlight lang="C">
typedef struct _Tpx3Pixel {
double toa;         // time of arrival [1 ns]
float tot;          // time over threshold [25 ns]
unsigned int index; // index of pixel position
} Tpx3Pixel;
</syntaxhighlight>
</syntaxhighlight>
The Pixet core has a circular buffer in memory. The default size is 100 MB. There are blocks in the buffer. The default block size is 66000 bytes. Incoming data is stored in a block. The “new data” event (that can start the callback or save the blockt to file) occurs if:
* The data size reaches the block size
* Some data is in block over the timeout (500 ms)
* The measurement ends
If you need to process data more often, you can set smaller block size. But if blocks are too small, data transfer speed can fall and some data can be lost. This can occurs if block size is less than approximately 5000 bytes (depends on computer speed and other circumstances).
;Example projects
:'''MiniPixTpx3-DataDriven''', commandline example – Set the parameters, use the callback and display the data, some auxiliary things and data convert. Save data to files. Without threads.
:'''AdvacamAPIexamples/Tpx3''', Windows GUI CLR app – All common functions including data-driven measurements. Using threads.
;Note
:Functions in this chapter is '''only for the Timepix3 devices''', not usable on other Timepixes or Medipixes.
= API data processing functions =
= The synchronizing =


= Related =
= Related =
* [[Pixet_SDK|Pixet SDK]]
* [[Pixet SDK]]
* [[Files and directories of the Pixet and SDK#Main directory of the API-using programs, independent on the Pixet|Files and directories: Main directory of the API-using programs]]
* [[Files and directories of the Pixet and SDK#Main directory of the API-using programs, independent on the Pixet|Files and directories: Main directory of the API-using programs]]
* [[File types]]

Latest revision as of 13:28, 6 November 2024

Core/basic binary (C/C++) API introduction

This API is part of the Advacam's Pixet SDK and allows access to functions of the Pixet Core.

The binary API parts are:

  1. Binary core/basic API (this document)
  2. Binary clustering API
  3. Binary spectral imaging API

See: Pixet SDK overview

Usage overview

  • Settings of the device
  • Getting information about the device
  • Single-frame measurement
  • Multi-frame measurement
  • Continuous frame measurement (endless repeats and without dead time on some devices, Mpx3 and Tpx2 for example)
  • Data-driven (pixel mode) measurement (Tpx3 only)
  • Synchronized measurement
  • TDI imaging - Scanning linearly moving objects, for example on a conveyor belt.
  • Basic image bad pixel correction
  • Beam hardening correction (Xray imaging has a very non-linear relationship between the thickness of the material and the intensity of the transmitted radiation. First, low-energy radiation is captured, followed by components that are significantly more penetrating.)

Libraries

The core API with the pxcore library, allowing basic measurements and device settings.
Files:

  • pxcapi.h API header file
  • pxcore.dll or pxcore.so binary libraries for Windows or Linux
  • pxcore.lib static linging file for easier using on Windows (compile time only)
  • common.h common file defining basic types, constatns and usefull macros. It's not necessary, but it can be useful.

And need some auxiliary files and directories:

Requirements

Hardware

This API requires computer with x86 compatible architecture or ARM with memory management features (no small MCU), 64bit Windows or Linux and connected some Advacam hardware with imaging chip. Medipix3, Timepix, Timepix2, Timepix3, etc. Some functions are universal for all hardwares (pxcInitialize, pxcGetDeviceName, etc), some is specialized for only one chip type (pxcMeasureSingleFrameTpx3 is Timepix3 only).

Specialized functions have names with chip type included:

  • pxcSetTimepixCalibrationEnabled – Timepix only (no Timepix3)
  • pxcMeasureTpx3DataDrivenMode – Timepix3 only
  • pxcMeasureSingleFrameMpx3 – Medipix3 only

The attempt to use the function if compatible hardware (in initialized state) not present, end with error.
Return code is PXCERR_UNEXPECTED_ERROR.

Software

All the API functions have heads in pxcapi.h, implemented for Windows in the pxcore.dll and for linking must use the pxcore.lib in the linker settings. Implementation for Linux is in the libcore.so.
Compiled program need the pixet.ini file with proper hwlibs list inside, necessary hardware dll files (eq minipix.dll for Minipixes), optional special files (eq zestwpx.bit for Widepixes), subdirectory “factory” with default config files for all present imaging devices (eq MiniPIX-I08-W0060.xml) and the Pixet core will create subdirectory “configs” to save changed configs on exit.
See The Pixet core, additional libraries and other files
Usually, for build, just set the compiler to use 64bit and the linker to use the pxcore.lib file.

In Microsoft visual studio, while creating the C++ CLR project, it is also necessary to insert the use of WIN32 definition into the project settings (C/C++ / Preprocessor / Preprocessor definitions):

Visual Studio Project Settings
Visual Studio Project Settings

The Pixet core, additional libraries and other files

Main files:

  • pxcapi.h API header file for importing to C/C++
  • pxcore.dll or pxcore.so binary libraries for Windows or Linux
  • pxcore.lib static linging file for easier using in C/C++ on Windows

And need some auxiliary files and directories:

Where to get these files?

All need files except XML configs are located in the zip file with name like us:
API_PIXet_Pro_1.8.2_Windows_x86_64.zip
Download: Advacam download page
Be careful about the correct libraries, we supply
  • Windows-x86-64b
  • Linux-x86-64b
  • Linux-ARM-32b
  • Linux-ARM-64b


And all files except LIB files for Windows compilation are located in the Pixet directory:
All files except LIB files for Windows compilation are located in the Pixet directory
All files except LIB files for Windows compilation are located in the Pixet directory

Example of the project directory

Example of the project dirrectory
Example of the project dirrectory

On the right is a screenshot of the Windows CLR APP project directory in Visual Studio that uses Minipix Tpx3. The marked files were copied from the Advacam SDK and the "factory" directory contains the configuration XML file for the device. It is important that the name is complete, eg MiniPIX-I08-W0060.xml. This file will be used on first launch.

The directory "configs" is created when Pixet core is terminated and contains a configuration XML file with saved current settings. This file will be used on each subsequent startup and updated on each subsequent exit.

The "logs" directory is created when Pixet core is started for the first time and contains LOG files from device activity and backups of these files for the last 10 starts.

Contents of the pixet.ini file:

[hwlibs]
minipix.dll

(x64, Myform... and TPx3-1... are from the MS Visual studio project)

Don't forget to set up WIN32 and pxcore.lib in the project settings as described in the parent chapter.

Tip: How to create the Windows CLR APP:
MSDN:create-c-windows-forms-application-in-visual-studio-2017

Example of the minimalistic program directory

Example of the minimalistic project dirrectory
Example of the minimalistic project dirrectory


Some examples

Simple C commandline example and build

Example code


This is simple example of commandline C program, whitch initializes the Pixet core and device, sets it's operation mode, measures single frame, saves the frame to some files and deinitializes the Pixet core with all the connected devices.
(Timepix3 only)

 #include "pxcapi.h"
 
 int main() {
     int rc; // return code
     
     printf("Initializing...\n");
     rc = pxcInitialize();
     printf("pxcInitialize: %d (0 is OK)\n", rc);
     
     rc = pxcSetTimepix3Mode(0, PXC_TPX3_OPM_TOATOT); // sets OPM of device with index 0
     printf("pxcSetTimepix3Mode: %d (0 is OK)\n", rc);
     
     // pxcMeasureMultipleFrames(deviceIndex, frameCount, acqTime, triggerSettings);
     rc = pxcMeasureMultipleFrames(0, 3, 1, PXC_TRG_NO);
     printf("pxcMeasureMultipleFrames: %d (0 is OK)\n", rc);
     
     // pxcSaveMeasuredFrame(deviceIndex, frameLastIndex, filename);
     rc = pxcSaveMeasuredFrame(0, 0, "testImg0.png");
     printf("pxcSaveMeasuredFrame 0: %d (0 is OK)\n", rc);
     rc = pxcSaveMeasuredFrame(0, 1, "testImg1.txt");
     printf("pxcSaveMeasuredFrame 1: %d (0 is OK)\n", rc);
     rc = pxcSaveMeasuredFrame(0, 2, "testImg2.pbf");
     printf("pxcSaveMeasuredFrame 2: %d (0 is OK)\n", rc);
     
     rc = pxcExit();
     printf("pxcExit: %d (0 is OK)\n", rc);
 }

Note: If You want test it in device other than Timepix3, You can comment lines with pxcSetTimepix3Mode. But then it is not clear what will be measured.

Building using cmake on Windows with Visual Studio installed


Example of CMakeLists.txt file for compiling this using cmake (C++ file is named "minipix1.cpp"):

 cmake_minimum_required(VERSION 3.10)
 project(minipix1)
 
 # include_directories(${CMAKE_SOURCE_DIR})
 # link_directories(${CMAKE_SOURCE_DIR})
 add_library(pxcore SHARED IMPORTED)
 set_property(TARGET pxcore PROPERTY IMPORTED_LOCATION "${CMAKE_SOURCE_DIR}/pxcore.dll")
 set_property(TARGET pxcore PROPERTY IMPORTED_IMPLIB  "${CMAKE_SOURCE_DIR}/pxcore.lib")
 add_executable(minipix1 minipix1.cpp)
 target_link_libraries(minipix1 pxcore)

Example of the Cmake building script:

 rmdir /s /q build
 mkdir build
 cd build
 cmake -DCMAKE_GENERATOR_PLATFORM=x64 .. 
 
 msbuild /P:Configuration=Release ALL_BUILD.vcxproj 
 
 cd .. 
 copy pxcore.dll build\Release\pxcore.dll
 copy minipix.dll build\Release\minipix.dll
 copy pixet.ini build\Release\pixet.ini
 echo build\Release\minipix1.exe > run.cmd

User can finally run the run.cmd to run the program.

Building on Linux using GCC


Example build.sh:

 #!/bin/bash
 gcc -o build-out minipix1.cpp -Wno-write-strings -L. -lpxcore  -ldl -lm -lc -g

Example run.sh to run the output executable:

 #!/bin/bash
 LD_LIBRARY_PATH=. ./build-out
 # run last compiled example
Troubleshooting
  • Be careful of library, platform and system compatibility.
That is, 32/64 bit, Intel vs ARM architecture and the use of unusual Linux distributions.
Example error message: skipping incompatible ./libpxcore.so when searching for -lpxcore
  • Be careful of gcc and it's libraries versions.
If too old, some errors will occur.
Example error message: undefined reference to symbol '_Znam@@GLIBCXX_3.4

C++ Windows CLR examples

AdvacamAPIexamples package

This is the packace of example apps for all device types.

Link
https://advacam.com/examples/AdvacamAPIexamples.rar
(MS Visual Studio 2017 Solution with C++ projects of Windows CLR programs)

C# examples

Notes:

  • Use the release/64 bit configuration
  • Functions that have optional parameters in pxcapi.h (for example pxcInitialize) must be declared with all parameters and then called, for example, with zeros.
  • The working directory is directory with the exe file. Typically project\bin\Release. Copy pixet.ini and other auxilliary files here.
  • In the MS Visual studio 2022 (and may be other), project first not working. You must click Properties, change .NET version to old, save it, change .NET version back to actual and save. Now project can work.
  • Our API can also be used to produce cross-platform software. In that case, be careful about the correct libraries, we supply Windows-x86-64b / Linux-x86-64b / Linux-ARM-32b / Linux-ARM-64b.

Simple C# commandline example

using System;
using System.Runtime.InteropServices;

namespace ConsoleApp1 {
    class Program {
        [DllImport("pxcore.dll", CallingConvention = CallingConvention.Cdecl)]
        public static extern int pxcInitialize(Int32 a, UInt64 b);

        [DllImport("pxcore.dll", CallingConvention = CallingConvention.Cdecl)]
        public static extern int pxcExit();

        [DllImport("pxcore.dll", CallingConvention = CallingConvention.Cdecl)]
        public static extern int pxcGetDevicesCount();
        static void Main(string[] args) {
            int rc;

            Console.WriteLine("pxcInitialize ...");
            rc = pxcInitialize(0, 0);
            Console.WriteLine($"rc={rc:D} (0 is OK)", rc);

            Console.WriteLine("pxcGetDevicesCount...");
            rc = pxcGetDevicesCount();
            Console.WriteLine("rc={0:D}\n", rc);

            if (rc > 0) {
                // do something now
            } else {
                Console.WriteLine("No devices detected\n");
            }

            Console.WriteLine("pxcExit...");
            rc = pxcExit();
            Console.WriteLine("rc={0:D} (0 is OK)", rc);

            Console.ReadKey();
        }
    }
}


Some more complex imports for inspiration:

 [DllImport("pxcore.dll", CallingConvention = CallingConvention.Cdecl)]
 public static extern int pxcGetDeviceChipID(UInt32 deviceIndex, UInt32 chipIndex, StringBuilder chipIDBuffer, UInt32 size);

 [DllImport("pxcore.dll", CallingConvention = CallingConvention.Cdecl)]
 public static extern int pxcGetDeviceDimensions(UInt32 deviceIndex, ref UInt32 width, ref UInt32 height);

 [DllImport("pxcore.dll", CallingConvention = CallingConvention.Cdecl)]
 public static extern int pxcMeasureSingleFrameTpx3(UInt32 deviceIndex, double frameTime, [Out] double[] frameToaITot, [Out] UInt16[] frameTotEvent, ref UInt32 size, UInt32 trgStg = 0);

C# Windows desktop example

See: C-sharp windows example

Xojo Basic Windows desktop example

See: Xojo windows example

API header definition

All API functions are defined in the pxcapi.h file. Each definition starting with the PXCAPI keyword:

#ifndef WIN32 // Linux
    #define PXCAPI extern "C" __attribute__ ((visibility("default")))
#else         // Windows
    #define PXCAPI extern "C" __declspec(dllexport)
#endif

API auxiliary functions

This chapter describes auxiliary functions. There are need for normal using of the device, but it not measuring or processing data.

Start-up, end, errors

pxcInitialize


This function initializes the Pixet software and all connected devices. This function has to be called first before any other function except pxcGetLastError. The init process of each device is:
  1. Initialize hardwrare and communication
  2. Try to load device XML config file from the "configs" dir
  3. If failed, try to load device XML config file from the "factory" dir
Warning: If the correct config is not loaded, the device will not work properly and may do strange things.

See

The factory and the configs subdirectories
Definition
PXCAPI int pxcInitialize(int argc = 0, char const* argv[] = NULL);

Parameters

  • argc – number of program command line arguments (optional parameter)
  • argv – command line program arguments (optional parameter)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Can be imported with parameters int32,uint64 and called with 0,0. Usesfull in languages other than C/C++.

Example

int rc = pxcInitialize();


pxcExit


This function deinitializes Pixet software and all the connected devices. This function has to be called as last function before unloading the pxcore library. The exit process of each device is:
  1. Save actual device XML config file to the "configs" dir
  2. Deinitialization of the hardware and communication

See

The factory and the configs subdirectories
Definition
PXCAPI int pxcExit();

Parameters

(no pars)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

int rc = pxcExit();


pxcSetDirectories


Sets the configuration files directory and directory for log files. Has to be set before calling the pxcInitialize function. Use it to change its default locations defined by pixet.ini.

See

Files and directories of the Pixet and SDK: The factory and the configs subdirectories
Definition
PXCAPI int pxcSetDirectories(const char* configsDir, const char* logsDir);

Parameters

  • configsDir – Path to the directory for loading/saving config files
  • logsDir – Path to the directory for saving log files
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcRefreshDevices


This function looks for newly connected devices and removed disconnected devices from the device list.
Definition
PXCAPI int pxcRefreshDevices();

Parameters

(no pars)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

int rc = pxcRefreshDevices();


pxcReconnectDevice


If the device was disconnected or experienced communication problems, this function will try to reconnect the device and reinitialize it. Like as do the pxcExit and pxcInitialize, but only for one device index. The process is:
  1. Saves the device config to the “configs” directory
  2. Disconnects the device
  3. Connects the device
  4. Loads the device config
Definition
PXCAPI int pxcReconnectDevice(unsigned deviceIndex);

Parameters

  • deviceIndex - index of the device, starting from zero
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

int rc = pxcReconnectDevice(0); // reconnect device with index 0


pxcGetLastError


Returns text of last error. This function can be called even before pxcInitialize()
Definition
PXCAPI int pxcGetLastError(char* errorMsgBuffer, unsigned size);

Parameters

  • errorMsgBuffer - buffer where text will be saved
  • size - size of supplied buffer
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

char msg[200];
pxcGetLastError(msg, 200);<br> printf("Error msg: %s\n", msg);


Example1 (console)

 #define ERRMSG_BUFF_SIZE 512
 #define ENTER_ON true
 #define ENTER_OFF false
 // (the function used in most examples in this manual)
 void printErrors(const char* fName, int rc, bool enter) {
    char errorMsg[ERRMSG_BUFF_SIZE];
    pxcGetLastError(errorMsg, ERRMSG_BUFF_SIZE);
    if (errorMsg[0]>0) {
        printf("%s %d err: %s", fName, rc, errorMsg);
    } else {
        printf("%s %d err: ---", fName, rc);
    }
    if (enter) printf("\n");
 }

Now you can use it:

 rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_EVENT_ITOT);
 printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);

If mode set was suscessfull, result is:

pxcSetTimepix3Mode 0 err: ---

If not, you can see some as:

pxcSetTimepix3Mode -2 err: Invalid device index


Example2 (Windows CLR)

 const unsigned cErrBufSize = 512;
 // primary use to show function name, return code, last error message
 bool errorToList(const char* fName, int rc) {
     char errorMsg[cErrBufSize];
     char cMsg[cErrBufSize];
     String^ eMsg;
     pxcGetLastError(errorMsg, cErrBufSize);
     if (rc!=0) {
         sprintf(cMsg, "%s %d err: %s", fName, rc, errorMsg);
         eMsg = gcnew String(errorMsg);
     } else {
         sprintf(cMsg, "%s %d err: ---", fName, rc);
     };
     String^ sMsg = gcnew String(cMsg);
     listMessages->Items->Add(sMsg);
     return (rc!=0);
 }

Now you can use it:

 rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_EVENT_ITOT);
 if (errorToList("pxcSetTimepix3Mode", rc)) return rc;

pxcGetIPixet


Returns a core pointer for processing libraries, Clustering or Spectral imaging for example.
Definition
PXCAPI void* pxcGetIPixet((void));

Parameters

(no pars)
Return value
core pointer


Parameter Get/Set functions (direct)

Functions described in this chapter working directly, function name defines parameter name and type.

For named parameters settings see: Parameter Get/Set functions (using text paramName)

Example: Setting operation mode


 // Set the operating mode
 rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_TOATOT);
 printErrors("pxcSetTimepix3Mode", rc);

Example: List of devices with parameters


 #include <stdio.h>
 #include "pxcapi.h"
 #define CHT_Si 0
 #define CHT_CdTe 1
 char chipType = CHT_Unknown;
 int main(int argc, char const* argv[]) { // #######################################
     int rc = pxcInitialize();
     if (rc) {
         printf("Could not initialize Pixet:\n");
         printErrors("pxcInitialize", rc, ENTER_ON);
         return -1;
     }
     int connectedDevicesCount = pxcGetDevicesCount();
     printf("Connected devices: %d\n", connectedDevicesCount);
     if (connectedDevicesCount == 0) return pxcExit();
     for (unsigned devIdx = 0; (signed)devIdx < connectedDevicesCount; devIdx++) {
         char deviceName[256];
         memset(deviceName, 0, 256);
         pxcGetDeviceName(devIdx, deviceName, 256);
         char chipID[256];
         memset(chipID, 0, 256);
         pxcGetDeviceChipID(devIdx, 0, chipID, 256);
         printf("Device %d: Name %s, (first ChipID: %s)\n", devIdx, deviceName, chipID);
     }
     double bias;
     rc = pxcGetBias(devIdx, &bias);
     if (bias < 0.0) {
         if (devIdx == 0) chipType = CHT_CdTe;
         printf("Chip material detected: CdTe\n");
     } else if (bias == 0.0) {
         printf("Chip material not detected!\n");
     } else {
         if (devIdx == 0) chipType = CHT_Si;
         printf("Chip material detected: Si\n");
     }
     printf("=================================================================\n");
     
     // here can be working code (calling some example function from this manual)
     
     return pxcExit();
 }

pxcGetDevicesCount


This function returns number of connected and initialized devices.
Definition
PXCAPI int pxcGetDevicesCount();

Parameters

(no pars)
Return value
Number of devices, otherwise the return value is a PXCERR_XXX code

Example

printf("Connected devices count: %d\n", pxcGetDevicesCount());


pxcListNetworkDevices


Searches for available network devices and store basic information about it to arrary. This is special function, independent of the Pixet Core. Can be used for listing devices without the PXcore initialized to prevent "steal" of other devices on the network. The output is usesfull to browse/testing network devices, it's IPs and availability on the network subnets.
Definition
PXCAPI int pxcListNetworkDevices(NetworkDevInfo* devInfos, unsigned* size);

Parameters

  • devInfos - Pointer to array of NetworkDevInfo{char ip[15]; char name[20]; int serial;} structures
  • size - [in] Pointer to size of the devInfo (number of elements) / [out] Value overwritten by the number of devices found
Return value
Returns 0 if OK or PXCERR_BUFFER_SMALL if the number of devices exceeded the size of the array (the array is still filled and *size is set)

Note

1. Can be used independent of the Pixet core.
2. A related feature is planned, allowing you to select devices to be used by PXcore. Currently you can write to the zest.ini instead.

Example

NetworkDevInfo ndi[256];
unsigned ndiSize = 256;
int rc;
msgToList("pxcListNetworkDevices...");
//pxcListNetworkDevices(NetworkDevInfo* devInfos, unsigned* size);
rc = pxcListNetworkDevices(ndi, &ndiSize);
errorToList("pxcListNetworkDevices", rc);
if (rc != 0 && rc != PXCERR_BUFFER_SMALL) return;
for (int n=0; n < ndiSize; n++) {
	msgToList(String::Format("  IP: {0}\t Name: {1}\t SN: {2}", gcnew String(ndi[n].ip), gcnew String(ndi[n].name), ndi[n].serial));
}
if (ndiSize == 0) msgToList("  (no devs found)");
else if (rc == PXCERR_BUFFER_SMALL) msgToList("  (and more devs than ndi array size)");


Network device info details:

struct NetworkDevInfo{
    char ip[15];
    char name[20];
    int serial;
};

pxcGetDeviceInfo


Gets device info structure and returns devType. If *devInfo is NULL, only returns devType.
Definition
PXCAPI int pxcGetDeviceInfo(unsigned deviceIndex, CDevInfo *devInfo);

Parameters

  • deviceIndex – index of the device, starting from zero
  • devInfo – pointer to CDevInfo struct
Return value
Device type number

Example

// simple use:
if (pxcGetDeviceInfo(devIdx, NULL) != TPX3) errorMsg("The device is not Timepix3");
// Advanced use:
CDevInfo devInfo[20];
char *dtStrings[] = {"Tpx", "Mpx3", "Tpx3", "Tpx2"};
for (int n=0; n<pxcGetDevicesCount(); n++) {
    pxcGetDeviceInfo(n, devInfo[n]);
    printf("DevIdx %d: Name: %s, SN: %d, DevType: %s", n, devInfo[n].name, devInfo[n].serial, dtStrings[devInfo[n].type+1]);
}


Device info details:

enum DevType{
    TPX = 1, MPX3, TPX3, TPX2,
};
struct CDevInfo{
    char name[20];
    int serial;
    DevType type;
};


pxcGetDeviceName


This function returns the full name of the selected device.
Definition
PXCAPI int pxcGetDeviceName(unsigned deviceIndex, char* nameBuffer, unsigned size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • nameBuffer – buffer where the name of the device will be saved. Cannot be NULL
  • size – size of the supplied name buffer
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

char name[100];
pxcGetDeviceName(deviceIndex, name, 100);
printf("Dev %d name: %s\n", deviceIndex, name);


pxcGetDeviceChipCount


This function returns number of chips in the device.
Definition
PXCAPI int pxcGetDeviceChipCount(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
Number of chips if successful, otherwise the return value is a PXCERR_XXX code.

Example

printf("Dev %d has chip count: %d\n", deviceIndex, pxcGetDeviceChipCount(deviceIndex));


pxcGetDeviceChipID


This function returns the ID of chip of the detector connected to the readout device.
Definition
PXCAPI int pxcGetDeviceChipID(unsigned deviceIndex, unsigned chipIndex, char* chipIDBuffer, unsigned size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • chipIndex – index of the chip in the device, starting from zero
  • chipIDBuffer – buffer where the chipID of the detector will be saved. Cannot be NULL
  • size - size of the supplied chipID buffer
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

char id[50];
int rc = pxcGetDeviceChipID(deviceIndex, 0, id, 50);
if (rc==0) printf("Chip 0 of dev %d have ID: %s\n", deviceIndex, id);
else printf("pxcGetDeviceChipID failed, code: %d\n", rc);


pxcGetDeviceSerial


This function returns the devise serial number.
Definition
PXCAPI int pxcGetDeviceSerial(unsigned deviceIndex);

Parameters

  • deviceIndex - index of the device, starting from zero
Return value
Serial number (>0) if successful, otherwise the return value is a PXCERR_XXX code.

Example

printf("Dev %d has serial number: %d\n", deviceIndex, pxcGetDeviceSerial(deviceIndex));


pxcGetDeviceDimmensions


This function gets pixel width and height of the device.
Definition
PXCAPI int pxcGetDeviceDimmensions(unsigned deviceIndex, unsigned *w, unsigned *h);

Parameters

  • deviceIndex - index of the device, starting from zero
  • w – pointer to unsigned variable where the width of the device will be returned
  • h – pointer to unsigned variable where the height of the device will be returned
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

unsigned w, h;
int rc = pxcGetDeviceDimmensions(deviceIndex, &w, &h);
if (rc==0) printf("Width: %d, Height %d [px]\n", w, h);
else printf("pxcGetDeviceDimmensions failed, code %d\n", rc);


pxcGetBias


This function gets the bias voltage (high voltage) of the sensor chip.
Definition
PXCAPI int pxcGetBias(unsigned deviceIndex, double* bias);

Parameters

  • deviceIndex – index of the device, starting from zero
  • bias – pointer to double variable where current bias will be returned
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

double bias;
int rc = pxcGetBias(deviceIndex, &bias);
if (rc==0) printf("Bias: %f V\n", bias);
else printf("pxcGetBias failed, code %d\n", rc);


pxcGetBiasRange


This function gets the range of the allowed minimal and maximal bias values.
Definition
PXCAPI int pxcGetBiasRange(unsigned deviceIndex, double* minBias, double* maxBias);

Parameters

  • deviceIndex - index of the device, starting from zero
  • minBias – pointer to double variable where minimum allowed bias will be returned
  • maxBias – pointer to double variable where maximum allowed bias will be returned
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

double min, max;
int rc = pxcGetBiasRange(deviceIndex, &min, &max);
if (rc==0) printf("Bias min: %f, max: %f V\n", min, max);
else printf("pxcGetBiasRange failed, code %d\n", rc);


pxcSetBias


This function sets the high voltage (bias) of the detector.
Definition
PXCAPI int pxcSetBias(unsigned deviceIndex, double bias);

Parameters

  • deviceIndex - index of the device, starting from zero
  • bias – high voltage in volts (limits and polarity depending on the device configuration, see: pxcGetBiasRange)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

int rc = pxcSetBias(0, -350); // set bias -350 V to device with idx 0


pxcGetThreshold


This function gets the threshold of the detector. Output value is normally in keV, but if the device not properly configurated, output is didital DAC value.
Definition
PXCAPI int pxcGetThreshold(unsigned deviceIndex, unsigned thresholdIndex, double* threshold);

Parameters

  • deviceIndex - index of the device, starting from zero
  • thresholdIndex – for all except Medipix3 always 0, for Medipix3 index of corresponding threshold starting from zero
  • threshold – pointer to double variable where threshold will be saved. The value is several keVs with decimals or from 0 to a some power of two (depending of device DAC bits depth).
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

double thl;
int rc = pxcGetThreshold(deviceIndex, &thl);
if (rc==0) printf("Threshold: %f\n", thl);
else printf("pxcGetThreshold failed, code %d\n", rc);


pxcGetThresholdRange


This function gets the allowed range of values for threshold. Output values are normally in keV, but if the device not properly configurated, output is didital DAC value.
Definition
PXCAPI int pxcGetThresholdRange(unsigned deviceIndex, int thresholdIndex, double* minThreshold, double* maxThreshold);

Parameters

  • deviceIndex - index of the device, starting from zero
  • thresholdIndex – for Timepix and Timepix3 always 0, for Medipix3 index of corresponding threshold starting from zero
  • minThreshold – pointer to double variable where the minimal allowed threshold will be returned
  • maxThreshold – pointer to double variable where the maximal allowed threshold will be returned
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

double min, max;
int rc = pxcGetThresholdRange(deviceIndex, &min, &max);
if (rc==0) printf("Threshold range - min: %f, max: %f\n", min, max);
else printf("pxcGetThresholdRange failed, code %d\n", rc);


pxcSetThreshold


This function sets the threshold of the detector in KeV.
Definition
PXCAPI int pxcSetThreshold(unsigned deviceIndex, unsigned thresholdIndex, double threshold);

Parameters

  • deviceIndex - index of the device, starting from zero
  • thresholdIndex - for Timepix and Timepix3 always 0, for Medipix3 index of corresponding threshold starting from zero
  • threshold – detector threshold in keV.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Warning

Too low thl value cause many noising pixels with all related problems.

Example

int rc = pxcSetThreshold(1, 0, 4.5); // set threshold with idx 0 on device with idx 1 to the 4.5 keV.


pxcGetDAC


This function gets a single DAC value of the detector.
Definition
PXCAPI int pxcGetDAC(unsigned deviceIndex, unsigned chipIndex, unsigned dacIndex, unsigned short* value);

Parameters

  • deviceIndex – index of the device, starting from zero
  • chipIndex – index of the chip, starting from zero
  • dacIndex – index of the DAC, starting from zero
  • value – pointer to output value be stored
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

unsigned short val;
int rc = pxcGetDAC(deviceIndex, chipIndex, dacIndex, &val);
if (rc==0) printf("Input value of DAC with idx %d, on chip with idx %d, of device with idx %d is: %d\n", deviceIndex, chipIndex, dacIndex, val);
else printf("pxcGetDAC failed, code %d\n", rc);


pxcSetDAC


This function sets a single DAC value of the detector.
Definition
PXCAPI int pxcSetDAC(unsigned deviceIndex, unsigned chipIndex, unsigned dacIndex, unsigned short value);

Parameters

  • deviceIndex – index of the device, starting from zero
  • chipIndex – index of the chip, starting from zero
  • dacIndex – index of the DAC, starting from zero
  • value – new DAC value
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

int rc = pxcSetDAC(0, 1, 2, 123); // set DAC with idx 3 on chip with idx 2 on device with idx 1 to the 123.


pxcGetTimepixClock


This function gets the current value of measurement clock for Timepix detector (in MHz).
Definition
PXCAPI int pxcGetTimepixClock(unsigned deviceIndex, double* clock);

Parameters

  • deviceIndex – index of the device, starting from zero
  • clock – pointer to double variable where the clock will be saved
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix devices, not usable on Timepix3 and other TimepixN. Timepix3 has a fixed clock of 40 MHz. Timepix2 has other clocks managenment.

Example

double val;
int rc = pxcGetTimepixClock(deviceIndex, &val);
if (rc==0) printf("Timepix clock: %f MHz\n", val);
else printf("pxcGetTimepixClock failed, code %d\n", rc);


pxcSetTimepixClock


This function sets the value of measurement clock for Timepix detector (in MHz). Not all values are possible, the result will be the closest possible frequency.
Definition
PXCAPI int pxcSetTimepixClock(unsigned deviceIndex, double clock);

Parameters

  • deviceIndex – index of the device, starting from zero
  • clock – desired value of the measurement clock for Timepix detector
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix devices, not usable on Timepix3 and other TimepixN. Timepix3 has a fixed clock of 40 MHz. Timepix2 has other clocks managenment.

Example

int rc = pxcSetTimepixClock(deviceIndex, 25.0);


pxcGetTimepixMode


This function gets the current value of the Timepix mode (Counting, Energy,…)
Definition
PXCAPI int pxcGetTimepixMode(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
Timepix mode if successful, otherwise the return value is a PXCERR_XXX code.
Timepix mode can be:
PXC_TPX_MODE_MEDIPIX – counting mode
PXC_TPX_MODE_TOT – energy mode
PXC_TPX_MODE_TIMEPIX – timepix mode if successful.
Otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix devices, not usable on Timepix3 and other TimepixN.

Example

int rc = pxcGetTimepixMode(deviceIndex);
if (rc>=0) printf("Mode of dev. idx %d is: %d\n", deviceIndex, rc);
else printf("pxcGetTimepixMode failed, code %d\n", rc);


pxcSetTimepixMode


This function sets the value of Timepix mode.
Definition
PXCAPI int pxcSetTimepixMode(unsigned deviceIndex, int mode);

Parameters

  • deviceIndex – index of the device, starting from zero
  • mode – new value of the Timepix mode. One of the values:
PXC_TPX_MODE_MEDIPIX – counting mode
PXC_TPX_MODE_TOT – energy mode
PXC_TPX_MODE_TIMEPIX – timepix mode
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix devices, not usable on Timepix3 and other TimepixN.

Example

int rc = pxcSetTimepixMode(0, PXC_TPX_MODE_MEDIPIX); // set dev 0 to mode counting alias MEDIPIX


pxcSetTimepixCalibrationEnabled


This function enables or disables the calibration of Timepix ToT counts to energy in keV
Definition
PXCAPI int pxcSetTimepixCalibrationEnabled(unsigned deviceIndex, bool enabled);

Parameters

  • deviceIndex – index of the device, starting from zero
  • enabled – if the calibration is enabled or disable
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix devices, not usable on Timepix3 and other TimepixN.

Example

int rc = pxcSetTimepixCalibrationEnabled(0, true); // enable ToT calibration to keVs on device with idx 0


pxcIsTimepixCalibrationEnabled


This function returns if the calibration of Timepix ToT counts to energy in keV is enabled.
Definition
PXCAPI int pxcIsTimepixCalibrationEnabled(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
0 if disabled, greater than 0 enabled, negative value a PXCERR_XXX code

Note

Only for the Timepix devices, not usable on Timepix3 and other TimepixN.

Example

int rc = pxcIsTimepixCalibrationEnabled(0);
if (rc>=0) printf("Calibration of dev0 is %s\n", (rc==0) ? "disabled" : "enabled");
else printf("pxcIsTimepixCalibrationEnabled failed, code %d\n", rc);


pxcGetTimepix2Clock


This function gets the current clocks settings in the Timepix2 detector.
Definition
PXCAPI int pxcGetTimepix2Clock(unsigned deviceIndex, double* totClock, double* toaClock, unsigned* divider);

Parameters

  • deviceIndex – index of the device, starting from zero
  • totClock – pointer to double variable where the ToT clock (in MHz) will be saved
  • toaClock – pointer to double variable where the ToA clock (in MHz) will be saved
  • divider – pointer to unsigned int variable where the divider value will be saved
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on Timepix3 and other Timepix. Timepix3 have a fixed

clock of 40 MHz.


pxcSetTimepix2Clock


This function sets Timepix2 detector clocks settings.
Definition
PXCAPI int pxcSetTimepix2Clock(unsigned deviceIndex, double clock, unsigned divider);

Parameters

  • deviceIndex – index of the device, starting from zero
  • clock – desired new value of the ToT clock (in MHz) for the Timepix2 detector. The real frequency will be nearest possible division by 2’s power from the 50 MHz. Min is 1.5625 MHz.
  • divider – value of the ToA divider index.
Values means 0: disable, 1: no division, 2-30: div. by 2n-1.
The ToA clock will be divided from the ToT clock.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on Timepix3 and other Timepix. Timepix3 have a fixed clock of 40 MHz.

Warning

The factory energy calibration is only for the 50 MHz ToA clock.


pxcSetTimepix2Mode


This function sets the value of Timepix2 mode
Definition
PXCAPI int pxcSetTimepix2Mode(unsigned deviceIndex, int mode);

Parameters

  • deviceIndex – index of the device, starting from zero
  • mode – new value of the Timepix2 mode. One of the values:
PXC_TPX2_OPM_TOT10_TOA18
PXC_TPX2_OPM_TOT14_TOA14
PXC_TPX2_OPM_CONT_TOT10_CNT4
PXC_TPX2_OPM_CONT_TOT14
PXC_TPX2_OPM_CONT_TOA10
PXC_TPX2_OPM_CONT_TOA14
PXC_TPX2_OPM_CONT_CNT10
PXC_TPX2_OPM_CONT_CNT14
PXC_TPX2_OPM_ITOT10_TOA18
PXC_TPX2_OPM_ITOT14_TOA14
PXC_TPX2_OPM_CONT_ITOT10_CNT4
PXC_TPX2_OPM_CONT_ITOT14
Modes desctiption
TOT – time of threshold in ToT ticks, or energy if calibrated
TOA – time of arrival in ToA ticks
CNT – count of hits
ITOT – integrated time of threshold in the pixel, or estimate energy if calibrated
CONT – continual mode: One counter set counting while reading data from other counter set
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.


pxcSetTimepix2AdaptiveGainMode


This function sets the value of Timepix2 mode.
Definition
PXCAPI int pxcSetTimepix2AdaptiveGainMode(unsigned deviceIndex, bool adaptiveGainOn);

Parameters

  • deviceIndex – index of the device, starting from zero
  • adaptiveGainOn – enable the adaptive gain feature
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.


pxcSetTimepix2AnalogueMaskingMode


This function sets the value of Timepix2 mode
Definition
PXCAPI int pxcSetTimepix2AnalogueMaskingMode(unsigned deviceIndex, bool analogMaskOn);

Parameters

  • deviceIndex – index of the device, starting from zero
  • analogMaskOn – enable the analogue masking feature
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.


pxcSetTimepix2CalibrationEnabled


This function enables or disables the calibration of Timepix ToT counts to energy in keV
Definition
PXCAPI int pxcSetTimepix2CalibrationEnabled(unsigned deviceIndex, bool enabled);

Parameters

  • deviceIndex – index of the device, starting from zero
  • enabled – if the calibration is enabled or disable
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Different acquisition or frame reading functions needed if calibration is on or off.
Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.


pxcIsTimepix2CalibrationEnabled


This function returns if the calibration of Timepix ToT counts to energy in keV is enabled
Definition
PXCAPI int pxcIsTimepix2CalibrationEnabled(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Different acquisition or frame reading functions needed if calibration is on or off.
Only for the Timepix2 devices, not usable on Timepix3 and other Timepix.


pxcSetTimepix3Mode


Sets the operation mode of Timepix3 detector
Definition
PXCAPI int pxcSetTimepix3Mode(unsigned deviceIndex, int mode);

Parameters

  • deviceIndex – index of the device, starting from zero
  • mode – mode of the detector PXC_TPX3_OPM_XXX values
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix3 devices, not usable on other Timepixes or Medipixes.


pxcSetTimepix3CalibrationEnabled


Enables/disables the calibration of Timepix3 ToT counts to energy in keV. If enabled, output of a frame maesurements on the device will be calibrated.
Definition
PXCAPI int pxcSetTimepix3CalibrationEnabled(unsigned deviceIndex, bool enabled);

Parameters

  • deviceIndex – index of the device, starting from zero
  • enabled – if calibraiton is enabled
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Calibration working properly only if the device has loaded proper config.


pxcIsTimepix3CalibrationEnabled


Gets if the calibration of Timepix3 ToT counts to energy in keV is enabled. See pxcSetTimepix3CalibrationEnabled for details.
Definition
PXCAPI int pxcIsTimepix3CalibrationEnabled(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
enabled > 0, disabled = 0, error < 0 – the return value is a PXCERR_XXX code.


pxcSetMedipix3OperationMode


Sets the operation mode of Medipix3 detector
Definition
PXCAPI int pxcSetMedipix3OperationMode(unsigned deviceIndex, int opMode);

Parameters

  • deviceIndex – index of the device, starting from zero
  • opMode – mode of the detector PXC_MPX3_OPM_XXX values
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Medipix3 devices, not usable on Timepixes or other Medipixes.


pxcSetMedipix3GainMode


Sets the gain mode of Medipix3 detector
Definition
PXCAPI int pxcSetMedipix3GainMode(unsigned deviceIndex, int gain);

Parameters

  • deviceIndex – index of the device, starting from zero
  • gain – mode of the detector PXC_MPX3_GAIN_MOD_XXX values
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Medipix3 devices, not usable on Timepixes or other Medipixes.


pxcSetMedipix3AcqParams


Sets acquisition parameters for Medipix3
Definition
PXCAPI int pxcSetMedipix3AcqParams(unsigned deviceIndex, bool colorMode, bool csm, int gain, bool equalize);

Parameters

  • deviceIndex – index of the device, starting from zero
  • colorMode – if color mode is enabled
  • csm – if charge sharing mode is enabled
  • gain – gain settings (PXC_MPX3_GAIN_XXX values)
  • equalize – if equalization bit in Medipix3 is enabled
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Medipix3 devices, not usable on Timepixes or other Medipixes.


pxcSetMedipix3MatrixParams


Sets parameters of the Meidpix3 pixel matrix
Definition
PXCAPI int pxcSetMedipix3MatrixParams(unsigned deviceIndex, int depth, int counter, int colBlock, int rowBlock);

Parameters

  • deviceIndex – index of the device, starting from zero
  • depth – depth of the counters PXC_MPX3_CNTD_XXX values
  • counter – selected counter (PXC_MPX3_CNT_XXX values)
  • colBlock – region of interest readout (PXC_MPX3_COLB_XXX values)
  • rowBlock – region of interest readout (PXC_MPX3_ROWB_XXX values)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Medipix3 devices, not usable on Timepix or other Medipixes.


pxcSetPixelMatrix


Sets the pixel matrix configuration. This is low level function for advanced users.
Definition
PXCAPI int pxcSetPixelMatrix(unsigned deviceIndex, unsigned char* maskMatrix, unsigned size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • maskMatrix – pixel mask matrix. 0 masked, 1 unmasked
  • size – size of the mask matrix
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcGetPixelMatrix


Gets the pixel matrix configuration. This is low level function for advanced users.
Definition
PXCAPI int pxcGetPixelMatrix(unsigned deviceIndex, unsigned char* maskMatrix, unsigned byteSize);

Parameters

  • deviceIndex – index of the device, starting from zero
  • maskMatrix – buffer where the mask matrix will be stored. 0 masked, 1 unmasked
  • size – size of the mask matrix
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


Metadata

Various devices, readout chips, detector chips and measurement methods have various metadata. To obtain informations about all relevant metadata for your purphose, set-up and run the testmeasurement with file-saving (using test code or Pixet program). Now you can read the accompanying DSC/INFO files, that contains all metadata for this combination of device/detector/measurement.

Frames and description files screenshot
Frames and description files screenshot
Example DSC records
"Chips layout" ("Order of chips in matrix"):
i32[5]
4 3 0 1 2
"Start time" ("Acquisition start time"):
double[1]
1659611081.595321
"Start time (string)" ("Acquisition start time (string)"):
char[64]
Thu Aug 4 13:04:41.595321 2022

pxcGetMetaDataValue


This function gets measured data meta data value. Output value is converted to char*.
Definition
PXCAPI int pxcGetMetaDataValue(unsigned deviceIndex, unsigned dataIndex, const char* metaDataName, char* valueBuffer, unsigned* size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • dataIndex - index of the measured data (frame), starting from zero
  • metaDataName – name of the metadata to get, "Start time" for example
  • valueBuffer – buffer where the value of the meta data as string will be stored
  • size – pointer to size of the supplied buffer
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

char mdb[200]; // metadata buffer
unsigned mdbs = 200; // metadata buffer size
char mdn[] = "Start time"; // metadata name

int rc = pxcGetMetaDataValue(deviceIndex, frameLastIndex, mdn, mdb, &mdbs);
if (rc != 0) errorToList("pxcGetMetaDataValue", rc);
else msgToList("Acquisition start time: " + gcnew String(mdb));


Parameter Get/Set functions (using text paramName)

In this chapter are a functions that working with named parameters. Alias readout parameters: Because originally it was only about the parameters of the readout chips. Later, the setting of other device and software parameters was also added.

For dirrect setting functions see: Parameter Get/Set functions (direct)

Example:

// Data Driven Block Size [B], default 66000
rc = pxcSetDeviceParameter(deviceIndex, "DDBlockSize", 6000);
printf("pxcSetDeviceParameter %d", rc);

Warning: Most parameters are for testing purposes only and you will not need them in normal use.

pxcGetDeviceParameter


Returns the value of integer device parameter (e.g. settings of trigger)
Definition
PXCAPI int pxcGetDeviceParameter(unsigned deviceIndex, const char* parameterName);

Parameters

  • deviceIndex – index of the device, starting from zero
  • parameterName – name of the device parameter
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcSetDeviceParameter


Sets a value of the integer device parameter (e.g. settings of trigger)
Definition
PXCAPI int pxcSetDeviceParameter(unsigned deviceIndex, const char* parameterName, int parameterValue);

Parameters

  • deviceIndex – index of the device, starting from zero
  • parameterName – name of the device parameter
  • parameterValue – new value of the parameter
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcGetDeviceParameterDouble


Returns the value of device double parameter
Definition
PXCAPI int pxcGetDeviceParameterDouble(unsigned deviceIndex, const char* parameterName, double* parameterValue);

Parameters

  • deviceIndex – index of the device, starting from zero
  • parameterName – name of the device parameter
  • parameterValue – pointer to double variable where the parameter value will be saved
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcSetDeviceParameterDouble


Sets a value of the device double parameter
Definition
PXCAPI int pxcSetDeviceParameterDouble(unsigned deviceIndex, const char* parameterName, double parameterValue);

Parameters

  • deviceIndex – index of the device, starting from zero
  • parameterName – name of the device parameter
  • parameterValue – new value of the parameter
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcGetDeviceParameterString


Returns the value of device string parameter
Definition
PXCAPI int pxcGetDeviceParameterString(unsigned deviceIndex, const char* parameterName, const char* parameterValue, unsigned size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • parameterName – name of the device parameter
  • parameterValue – pointer to string buffer where the parameter value will be saved
  • size – size of the passed buffer
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcSetDeviceParameterString


Sets a value of the device string parameter
Definition
PXCAPI int pxcSetDeviceParameterString(unsigned deviceIndex, const char* parameterName, const char* parameterValue);

Parameters

  • deviceIndex – index of the device, starting from zero
  • parameterName – name of the device parameter
  • parameterValue – new value of the parameter
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


Tpx3 parameter names list


Warning: Most parameters are for testing purposes only and you will not need them in normal use.

#define PAR_LIBVER        "HwLibVer"
#define PAR_DEBUGLOG      "DebugLog"
#define PAR_DUMMYACQ      "DummyAcqNegativePolarity"
#define PAR_TEMP          "Temperature"
#define PAR_TEMP_CHIP     "TemperatureChip"
#define PAR_TEMP_CPU      "TemperatureCpu" // mimipix/tpx3 only
#define PAR_TEMP_CHIP_CPU "TemperatureChipCpu" // mimipix/tpx3 only
#define PAR_TEMP_READ_ACQSERIE "TemperatureReadBeforeAcqSerie" // mimipix/tpx3 only
#define PAR_TEMP_READ_EVERYACQ "TemperatureReadBeforeEachAcq" // mimipix/tpx3 only
#define PAR_TEMP_CHECK_IN_SW "CheckMaxTempInSW" // mimipix/tpx3 only
#define PAR_TEMP_CHECK_IN_CPU "CheckMaxChipTempInCPU" // mimipix/tpx3 only
#define PAR_TEMP_MAX_ALLOWED_TEMP "MaxAllowedChipTemp" // mimipix/tpx3 only
#define PAR_DAC_BANGAP      "DacBandGap"
#define PAR_DAC_TEMP        "DacTemp"
#define PAR_BIAS_SENSE_VOLT "BiasSenseVoltage"
#define PAR_BIAS_SENSE_CURR "BiasSenseCurrent"
#define PAR_DD_BUFF_SIZE    "DDBuffSize"
#define PAR_DD_BLOCK_SIZE   "DDBlockSize"
#define META_SHUTTER_TIME   "Shutter open time" // mimipix/tpx3 only
#define PAR_CHAN_MASK       "ChanMask" // no net/tpx3
#define PAR_READOUT_CLOCK   "ReadoutClock" // no net/tpx3
#define PAR_TRG_STG         "TrgStg"
#define PAR_TRG_TIMESTAMP   "TrgTimestamp"
#define PAR_TRG_T0SYNC_RESET "TrgT0SyncReset"
#define PAR_TRG_READY        "TrgReady" // no net/tpx3
#define PAR_TRG_OUTLEVEL     "TrgOutLevel" // mimipix/tpx3 only
#define PAR_TRG_OUT_ENABLE   "TrgOutEnable" // mimipix/tpx3 only
#define PAR_TRG_IS_MASTER    "IsMaster"
#define PAR_MOTOHOURS        "Motohours" // mimipix/tpx3 only
#define PAR_MTX              "MTX" // mimipix/tpx3 only
#define PAR_SEND_TOA_PIXELS  "SendDummyToaPixels" // mimipix/tpx3 only
#define PAR_DUMMYSPEED       "DDDummyDataSpeed" // no mimipix/tpx3
#define PAR_BLOCKCOUNT       "BlockCount" // no mimipix/tpx3
#define PAR_PROCESSDATA      "ProcessData" // no mimipix/tpx3
#define PAR_TRG_MULTI        "TrgMulti" // no mimipix/tpx3
#define PAR_ADVAPIX_ADC      "AdvaPixADC" // no mimipix/tpx3
#define PAR_TRG_READY        "TrgReady" // zem only
#define PAR_TRG_CMOS         "TrgCmos" // zem only
#define PAR_READOUT_CLOCK    "ReadoutClock" // zem only

Tpx2 parameter names list


Warning: Most parameters are for testing purposes only and you will not need them in normal use.

const static char* PAR_LIBVER = "HwLibVer";
const static char* PAR_DEBUGLOG = "DebugLog";
const static char* PAR_BIAS_SENSE_VOLT = "BiasSenseVoltage";
const static char* PAR_BIAS_SENSE_CURR = "BiasSenseCurrent";
const static char* PAR_READOUT_CLOCK = "ReadoutClock";
const static char* PAR_TRG_STG = "TrgStg";
const static char* PAR_TRG_IS_MASTER = "IsMaster";
const static char* PAR_MOTOHOURS = "Motohours";
const static char* PAR_TEMP_CPU = "TemperatureCpu";
const static char* PAR_TEMP_MAX_ALLOWED_TEMP = "MaxAllowedChipTemp";
const static char* PAR_POWER_VOLT = "PowerSupplyVoltage";
const static char* PAR_CPU_SUPPLY_VOLT = "CPUSupplyVoltage";
const static char* PAR_CHIP_LDO_VOLT = "ChipLDOVoltage";
const static char* PAR_INPUT_CURRENT = "DeviceInputCurrent";
const static char* PAR_CHIP_CURRENT = "ChipCurrent";

Mpx2 (Timepix) parameter names list


Warning: Most parameters are for testing purposes only and you will not need them in normal use.

#define PAR_LIBVER        "HwLibVer" // all, include minipixes
#define PAR_DEBUGLOG      "DebugLog" // all, include minipixes
#define CFG_BINPIXCFG     "BinaryPixelCfg" // fei-minipix only
#define PAR_FIRMWARE      "Firmware" //widepix only
#define PAR_PS_COUNT      "PreShutterClockCount"
#define PAR_PS_DIVIDER    "PreShutterClockDivider"
#define PAR_PS_DELAY      "PreShutterDelayClockCount"
#define PAR_TEMP          "Temperature" // no zem
#define PAR_BIASINCPU     "BiasInCpu" // widepix only
#define PAR_TRG_STG       "TriggerStg"
#define PAR_TRG_WAITREADY "TriggerWaitForReady"
#define PAR_TRG_MASTER    "TriggerMaster"
#define PAR_TRG_OUTLEVEL  "TriggerOutLevel"
#define PAR_TRG_ALTERNATIVE "TriggerAlternative" // fitpix only
#define PAR_TRG_TWODEVS   "TriggerTwoDevs" // fitpix only
#define PAR_BURST_DISABLE "BurstDisable" // fitpix only
#define PAR_CPU_BIAS_SET  "*BiasSet" // widepix only
#define PAR_CPU_BIAS_VOLTSENSE "BiasVolt" // widepix only
#define PAR_CPU_BIAS_CURRSENSE "BiasCurr" // widepix only
#define PAR_CPU_TEMP_DET  "TempDet" // widepix only
#define PAR_FASTACQ       "FastAcq" // zem only
#define PAR_BURST_FRAME_COUNT "BurstFrameCount" // zem only
#define PAR_PIXEL_BUFFSIZE "PixelBuffSize" // zem only

Mpx3 parameter names list


Warning: Most parameters are for testing purposes only and you will not need them in normal use.

#define PAR_LIBVER            "HwLibVer"
#define PAR_DEBUGLOG          "DebugLog"
#define PAR_TEMP              "Temperature"
#define PAR_TRG_STG           "TriggerStg"
#define PAR_TRG_WAITREADY     "TriggerWaitForReady"
#define PAR_TRG_MASTER        "TriggerMaster"
#define PAR_TRG_OUTLEVEL      "TriggerOutLevel"
#define PAR_TRG_SERIES        "TriggerTdiSeries"
#define PAR_TDI_ROWCOUNT      "TdiRowCount"
#define PAR_BIASINCPU         "BiasInCpu"
#define PAR_BIAS_DISCHARGE    "BiasDischarge"
#define PAR_CPU_BIAS_SET      "*BiasSet"
#define PAR_CPU_BIAS_VOLTSENSE "BiasVolt"
#define PAR_CPU_BIAS_CURRSENSE "BiasCurr"
#define PAR_CPU_TEMP_DET       "TempDet"

Zest-wpxdev parameter names list


Warning: Most parameters are for testing purposes only and you will not need them in normal use.

const static char* PAR_LIBVER = "HwLibVer";
const static char* PAR_FIRMWARE = "Firmware";
const static char* PAR_FIRMWARE_CPU = "FirmwareCpu";
const static char* PAR_DEBUGLOG = "DebugLog";
const static char* PAR_TEMP = "Temperature";
const static char* PAR_TRG_STG = "TriggerStg";
const static char* PAR_TRG_WAITREADY= "TriggerWaitForReady";
const static char* PAR_TRG_MASTER = "TriggerMaster";
const static char* PAR_TRG_OUTLEVEL = "TriggerOutLevel";
const static char* PAR_BIAS_DISCHARGE = "BiasDischarge";

Zem-wpx7dev parameter names list


Warning: Most parameters are for testing purposes only and you will not need them in normal use.

#define PAR_LIBVER            "HwLibVer"
#define PAR_DEBUGLOG          "DebugLog"
#define PAR_PS_COUNT          "PreShutterClockCount"
#define PAR_PS_DIVIDER        "PreShutterClockDivider"
#define PAR_PS_DELAY          "PreShutterDelayClockCount"
#define PAR_ENC_PULSE_CNT     "EncoderPulseCount"
#define PAR_ENC_PULSE_DIR     "EncoderDirection"
#define PAR_ENC_PULSE_COUNTER "EncoderPulseCounter"

Other auxilliary functions

pxcLoadDeviceConfiguration


This function loads device configuration from xml file
Definition
PXCAPI int pxcLoadDeviceConfiguration(unsigned deviceIndex, const char* filePath);

Parameters

  • deviceIndex – index of the device, starting from zero
  • filePath – path to xml configuration file
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcSaveDeviceConfiguration


This function saves device configuration to xml file
Definition
PXCAPI int pxcSaveDeviceConfiguration(unsigned deviceIndex, const char* filePath);

Parameters

  • deviceIndex – index of the device, starting from zero
  • filePath – path to xml configuration file
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcSetupTestPulseMeasurement


Enables / Disables and setups parameters of the test pulse measurements
Definition
PXCAPI int pxcSetupTestPulseMeasurement(unsigned deviceIndex, bool tpEnabled, double height, double period, unsigned count, unsigned spacing);

Parameters

  • deviceIndex – index of the device, starting from zero
  • tpEnabled – enables/disables test pulse measurement (in functions Measure..Frame(s))
  • height – test pulse height (0 – 1.5 V)
  • period – single test pulse period (1 – 256 us)
  • count – number of test pulses (1 – 10000)
  • spacing – spacing that is used during measurement (sub acquisition), good value is 4
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcRegisterAcqEvent


Registers an acquisition event callback that is called when corresponding event occurs
Definition
PXCAPI int pxcRegisterAcqEvent(unsigned deviceIndex, const char* event, AcqEventFunc func, intptr_t userData);

Parameters

  • deviceIndex – index of the device, starting from zero
  • event – event name (PXC_ACQEVENT_XXX values)
  • func – callback function of type AcqEventFunc
  • userData – user data that are passed to callback function. Use this as pointer or as 32/64bit integer, depending on system pointer size. The callback function will receive the userData value.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


The AcqEventFunc definition:

typedef void (*AcqEventFunc)(intptr_t eventData, intptr_t userData);

pxcUnregisterAcqEvent


Unregisters the acquisition event callback
Definition
PXCAPI int pxcUnregisterAcqEvent(unsigned deviceIndex, const char* event, AcqFunc func, intptr_t userData);

Parameters

  • deviceIndex – index of the device, starting from zero
  • event – event name (PXC_ACQEVENT_XXX values)
  • func – callback function of type AcqFunc
  • userData – user data pointer that was used in pxcRegisterAcqEvent, for proper indetify the event
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcSetSensorRefresh


Sets the sensor refresh sequence text. The sensor refresh is used to clean the sensor of free charges. Process containing sequence of bias changes. Suitable values depend on chip manufacturing technology details.
For more details see: pxcDoSensorRefresh
Definition
PXCAPI int pxcSetSensorRefresh(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
  • refreshString – sensor refresh string
refresh string defines steps with pairs of times [sec] and bias coefficients [1=100%]
(physical bias values limited to min/max chip properties, see pxcGetBiasRange)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Warning

Special function for scientific or device developing using. Normally it not usesfull, normally use the default refresh parameters loaded from factory config.

Example

// (devIdx, "time1, coef1; time2, coef2; time3, coef3; ...")
int rc = pxcSetSensorRefresh(0, "5, 2; 3, 1.5; 1, 1.2; 1, 1");
printErrors("pxcSetSensorRefresh", rc, ENTER_ON);


pxcDoSensorRefresh


Performs the sensor refresh. The sensor refresh is used to clean the sensor of free charges. Process containing sequence of bias changes and may take several seconds.
Useful for devices with CdTe or CZT chip:
  1. Before the measurement, which should start right after the initialization.
  2. To improve the repeatability of measurements
Definition
PXCAPI int pxcDoSensorRefresh(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

This is an analog part refresh, not a recovery from a digital failure.


pxcEnableSensorRefresh


Enables automatic sensor refresh before each acquisition series and at periodic intervals.
For more details see: pxcDoSensorRefresh
Definition
PXCAPI int pxcEnableSensorRefresh(unsigned deviceIndex, bool enabled, double refreshTime);

Parameters

  • deviceIndex – index of the device, starting from zero
  • enabled – if automatic sensor refresh is enabled
  • refreshTime – sensor refresh is performed repeatedly after this time in seconds.
If thime is 0, then the refresh is done only once before the measurement
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

This is an analog part refresh, not a recovery from a digital failure.


pxcEnableTDI


Enables TDI (Time Delayed Integration) measurement (if device supports it, single line Mpx3 for example). Usesful for scanning of linearly moving objects.
Definition
PXCAPI int pxcEnableTDI(unsigned deviceIndex, bool enabled);

Parameters

  • deviceIndex – index of the device, starting from zero
  • enabled – if TDI is enabled
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcIsReadyForSoftwareTrigger


Checks if the device is ready to accept software trigger.
Definition
PXCAPI int pxcIsReadyForSoftwareTrigger(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
1 if ready, 0 if not ready, and negative if error, PXCERR_XXX code.

Note

If you want to use this immediately after a function for starting acquisition, wait until it's ready by using pxcIsReadyForSoftwareTrigger.

Example

int rc = pxcIsReadyForSoftwareTrigger(deviceIndex);
if (rc==1) msgToList("Dev is ready to SW trigger");
else if (rc==0) msgToList("Dev is not ready to SW trigger");
else errorToList("pxcIsReadyForSoftwareTrigger", rc);


pxcDoSoftwareTrigger


Sends the software trigger: Start of acquisition with trgStg=PXC_TRG_SWSTART used.
Definition
PXCAPI int pxcDoSoftwareTrigger(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


API frame-based measuring functions

Basic frame measuring example
Basic frame measuring example

The functions described in this chapter are used for frame-based measurements. Suitable for imaging, for example. After acquisition ends, you can read all the frame data (65536 pixels from every chip) to your buffer or save to the file. Acquisition can start by software (afther call a function, for example), or by HW trigger. Data types depends on chip technology and the operation mode.

Chip can generate one or two data blocks (event count and integrated times over threshold, for example) in one acquisition. Do not forget to set the operation mode. If mode not set, some devices measure something, but some other devices measure something else in this case.

Example projects
MiniPixTpx3-Frames – mode set, single frame, multiple frames with/without callback, continuous measuring

pxcMeasureSingleFrame


Performs a measurement of single frame and returns its data
Definition
PXCAPI int pxcMeasureSingleFrame(unsigned deviceIndex, double frameTime, unsigned short* frameData, unsigned* size, unsigned trgstg);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameTime – time of the measurment in seconds
  • frameData – pointer to buffer where data will be saved. For single detector size is 65536
  • size – pointer to varible with the size of the buffer. The actual size will be output to this variable
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

This function have only one framebuffer. This is fully sufficient for single-output devices and modes. In combined modes (ToA+ToT, Event+IToT, dual threshold) only first data are available (ToA, Event, Threshold0). To take both outputs from the combined modes, it is necessary to use specialized functions for the given type of detector.


pxcMeasureSingleFrameMpx3


Performs a measurement of single frame and returns its data. This is only for Medipix3 chips
Definition
PXCAPI int pxcMeasureSingleFrameMpx3(unsigned deviceIndex, double frameTime, unsigned* frameData1, unsigned* frameData2, unsigned* size, unsigned trgstg);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameTime – time of the measurment in seconds
  • frameData1 – pointer to buffer where data from first counter will be saved. For single detector chip, size is 65536
  • frameData2 – pointer to buffer where data from second counter will be saved. For single detector chip, size is 65536
  • size – pointer to varible with the size of the buffer. The actual size will be output to this variable
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Medipix3 devices, not usable on Timepix or other Medipixes.


pxcMeasureSingleFrameTpx3


Performs a measurement of single frame and returns its data. This is only for Timepix3 detector.
Definition
PXCAPI int pxcMeasureSingleFrameTpx3(unsigned deviceIndex, double frameTime, double* frameToaITot, unsigned short* frameTotEvent, unsigned* size, unsigned trgstg);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameTime – time of the measurment in seconds
  • frameToaITot – pointer to buffer where data from ToA or iToT counter (based on set operation mode) will be saved. For single detector chip, size is 65536
  • frameTotEvent – pointer to buffer where data from ToT or Event counter (based on set operation mode) will be saved. For single detector chip, size is 65536
  • size – pointer to varible with the size of the buffer. The actual size will be output to this variable
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix3 devices, not usable on other Timepixes or Medipixes.

Example

void pxcMeasureSingleFrameTpx3Test(unsigned di) { // di – device index ========
   int rc;                               // return codes
   const unsigned cSize = 65536;         // chip pixels count
   unsigned short frameTotEvent[cSize];  // frame data - event count
   double frameToaITot[cSize];           // frame data - integrated time over threshold
   double time = 1.0;                    // frame acquisition time
   unsigned size = cSize;                // buffer size and measured data size
   int mode = PXC_TPX3_OPM_EVENT_ITOT;
   rc = pxcSetTimepix3Mode(di, mode);
   printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
   rc = pxcMeasureSingleFrameTpx3(di, time, frameToaITot, frameTotEvent, &size, PXC_TRG_NO);
   printErrors("pxcMeasureSingleFrameTpx3", rc, ENTER_ON);
   showFrameDual(frameTotEvent, frameToaITot, mode);
}


pxcMeasureSingleFrameTpx2


Performs a measurement of single frame and returns its data. This is only for Timepix2 detector and only if calibration is disabled
Definition
PXCAPI int pxcMeasureSingleFrameTpx2(unsigned deviceIndex, double frameTime, unsigned* frameData1, unsigned* frameData2, unsigned* size, unsigned trgStg);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameTime – time of the measurment in seconds
  • frameData1 – pointer to buffer where data from the first counter (based on set operation mode) will be saved. For single detector chip, size is 65536
  • frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single detector chip, size is 65536
  • size – pointer to varible with the size of the buffer. The actual size will be output to this variable
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
Only if Timepix2 calibration is disabled.

Example

void pxcMeasureSingleFrameTpx2Test(unsigned di) { // di – device index ========
   int rc;                        // return codes
   const unsigned cSize = 65536;  // chip pixels count
   unsigned frameData1[cSize];    // frame data - ToT data
   unsigned frameData2[cSize];    // frame data - ToA data
   double time = 1.0;             // frame acquisition time
   unsigned size = cSize;         // buffer size and measured data size
   int mode = PXC_TPX2_OPM_TOT10_TOA18;
   rc = pxcSetTimepix2Mode(di, mode);
   printErrors("pxcSetTimepix2Mode", rc, ENTER_ON);
   rc = pxcMeasureSingleFrameTpx2(di, time, frameData1, frameData2, &size, PXC_TRG_NO);
   printErrors("pxcMeasureSingleFrameTpx2", rc, ENTER_ON);
   showFrameDual(frameData1, frameData2, mode);
}


pxcMeasureSingleCalibratedFrameTpx2


Performs a measurement of single frame, calibrate ToT to energy and returns data. This is only for Timepix2 detector and only if calibration is enabled
Definition
PXCAPI int pxcMeasureSingleCalibratedFrameTpx2(unsigned deviceIndex, double frameTime, double* frameData1, unsigned* frameData2, unsigned* size, unsigned trgStg);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameTime – time of the measurment in seconds
  • frameData1 – pointer to buffer where data from the first counter (based on set operation mode) will be saved. For single detector chip, size is 65536
  • frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single detector chip, size is 65536
  • size – pointer to varible with the size of the buffer. The actual size will be output to this variable
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
Only if Timepix2 calibration is enabled.

Example

void pxcMeasureSingleCalibratedFrameTpx2Test(unsigned di) { // di – device index =====
   int rc;                        // return codes
   const unsigned cSize = 65536;  // chip pixels count
   double frameData1[cSize];      // frame data - ToT data = calibrated to energy
   unsigned frameData2[cSize];    // frame data - ToA data
   double time = 1.0;             // frame acquisition time
   unsigned size = cSize;         // buffer size and measured data size
   int mode = PXC_TPX2_OPM_TOT10_TOA18;
   rc = pxcSetTimepix2Mode(di, mode);
   printErrors("pxcSetTimepix2Mode", rc, ENTER_ON);
   rc = pxcMeasureSingleCalibratedFrameTpx2(di, time, frameData1, frameData2, &size, PXC_TRG_NO);
   printErrors("pxcMeasureSingleCalibratedFrameTpx2", rc, ENTER_ON);
   showFrameDual(frameData1, frameData2, mode);
}


pxcMeasureMultipleFrames


Performs a measurement of several frames to memory
Definition
PXCAPI int pxcMeasureMultipleFrames(unsigned deviceIndex, unsigned fameCount,  double frameTime, unsigned trgStg);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameCount – numeber of frames to measure
  • frameTime – time of the measurment in seconds
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

void pxcMeasureMultipleFramesTpx3Test() { // =========================
   int rc;                              // return codes
   const unsigned cSize = 65536;        // chip pixels count
   unsigned short frameTotEvent[cSize]; // frame data - event count
   double frameToaITot[cSize];          // frame data - integrated time over threshold
   double frameTime = 1.0;              // frame acquisition time
   unsigned frameCount = 5;             // frame count
   unsigned size = cSize;               // buffer size and measured data size

   int mode = PXC_TPX3_OPM_EVENT_ITOT;
   rc = pxcSetTimepix3Mode(0, mode);
   printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);

   printf("measuring %d frames...\n", frameCount);

   pxcMeasureMultipleFrames(0, frameCount, frameTime, PXC_TRG_NO);
   printErrors("pxcMeasureMultipleFrames", rc, ENTER_ON);
   for (unsigned n=0; n<frameCount; n++) {
      rc = pxcGetMeasuredFrameTpx3(0, n, frameToaITot, frameTotEvent, &size);
      printErrors("pxcGetMeasuredFrameTpx3", rc, ENTER_ON);
      size = cSize;
      showFrameDual(frameTotEvent, frameToaITot, mode);
   }
}


pxcMeasureMultipleFramesWithCallback


Performs a measurement of several frames to memory. When each frame is measured, the supplied callback function is called and the userData parameter is passed as argument.
Definition
PXCAPI int pxcMeasureMultipleFramesWithCallback(unsigned deviceIndex, unsigned fameCount, double frameTime, unsigned trgStg, FrameMeasuredCallback callback, intptr_t userData);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameCount – numeber of frames to measure
  • frameTime – time of the measurment in seconds
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
  • callback – pointer to function of FrameMeasuredCallback type
  • userData – pointer to some user object/memory that is passed in callback function
See pxcRegisterAcqEvent for userData details
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

void pxcMeasureMultipleFramesWithCallbackTestTpx3(unsigned deviceIndex) { // ==============
	int rc; // return codes
	double frameTime = 1;
	unsigned frameCount = 5;
	tMmfClbData usrData;
	usrData.di = deviceIndex;
	usrData.opm = PXC_TPX3_OPM_EVENT_ITOT;
	rc = pxcSetTimepix3Mode(deviceIndex, usrData.opm);
	printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);
	rc = pxcMeasureMultipleFramesWithCallback
	(deviceIndex, frameCount, frameTime, PXC_TRG_NO, mmfCallback, (intptr_t)&usrData);
	printErrors("pxcMeasureMultipleFramesWithCallback", rc, ENTER_ON);
	// Measure function ends, after all callbacks are serviced
}

void mmfCallback(intptr_t acqCount, intptr_t userData) { // =================================
	int rc; // return codes
	const unsigned cSize = 65536; // chip pixels count
	unsigned short frameTotEvent[cSize]; // frame data - event count
	double frameToaITot[cSize]; // frame data - integrated time over threshold
	unsigned size = cSize; // buffer size and measured data size
	tMmfClbData usrData = *((tMmfClbData*)userData); // data transferred from start function
	printf("mmfCallback acqCount=%d, di=%d\n", (unsigned)acqCount, usrData.di);
	rc = pxcGetMeasuredFrameTpx3
	(usrData.di, (unsigned)acqCount - 1, frameToaITot, frameTotEvent, &size);
	printErrors("pxcGetMeasuredFrameTpx3", rc, ENTER_OFF); printf(", size=%d\n", size);
	if (rc == 0) {
		printf("Measured frame index %lu, ", (unsigned)acqCount - 1);
		printf("count %d\n", pxcGetMeasuredFrameCount(usrData.di));
		showFrameDual(frameTotEvent, frameToaITot, usrData.opm);
	}
}
//The acqCount contains count of measured frames that are currently waiting in memory.
// You can use acqCount-1 as frame index to read.
// The userData is 64b number used to transfer some data from starting function to callback function.
// You can use it as data pointer like in this example, or simply as number with some overtyping.
typedef struct { // structure for userData, that is using in mmfCallback
	unsigned di; // device index
	int opm; // operation mode
} tMmfClbData;


pxcMeasureContinuous


Performs an “endless” measurement of several frames to memory. The measurement is run until it’s aborted by pxcAbortMeasurement function. When each frame is measured, the supplied callback function is called and the userData parameter is passed as argument.
Definition
PXCAPI int pxcMeasureContinuous(unsigned deviceIndex, unsigned fameBufferSize, double frameTime, unsigned trgStg, FrameMeasuredCallback callback, intptr_t userData);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameBufferSize – number of frames in circular buffer
  • frameTime – time of the measurment in seconds
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO.
  • callback – pointer to function of FrameMeasuredCallback type
  • userData – pointer to some user object/memory that is passed in callback function
See pxcRegisterAcqEvent for userData details
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

  • This function, differently to other multi-frame measurements, not waiting for process end. It simply start measurement and program continue next.
  • You can set-up the callback by 2 ways:
  1. Simply use pointer to callback function in the pxcMeasureContinuous function. After do it, the commandline program must not leave the function in which pxcMeasureContinuous was used until the measurement is canceled.
  2. First use the pxcRegisterAcqEvent to set-up the callback, second use pxcMeasureContinuous without callback pointer or with NULL. Now it is possible to leave the superior function and measuring continue working independent. Afther cancel of the measurement, may be needed use the pxcUnregisterAcqEvent before other use of the Acq event.

Warning

Aborting measuremet from its callback (like as in commandline example bellow) can cause lags for tens of seconds. If the pxcAbortMeasurement called by other way (Button event in GUI for example), abort is fast.

Example

void pxcMeasureContinuousTestTpx3(unsigned deviceIndex) { // ==============================
	int rc; // return codes
	double frameTime = 2;
	unsigned buffrerFrames = 3;
	tMmfClbData usrData;
	usrData.di = deviceIndex;

	usrData.cnt = 0; // num of frames to stop in callback (0 endless)
	usrData.opm = PXC_TPX3_OPM_EVENT_ITOT;
	rc = pxcSetTimepix3Mode(deviceIndex, usrData.opm);
	printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);

	// method 1 (single step):
	//rc = pxcMeasureContinuous	(deviceIndex, buffrerFrames, frameTime, PXC_TRG_NO, mcCallback, (intptr_t)&usrData);
	//printErrors("pxcMeasureContinuous", rc, ENTER_ON);
	// method 2 (2 steps):
	// register event
	pxcRegisterAcqEvent(0, PXC_ACQEVENT_ACQ_FINISHED, mcCallback, (intptr_t)&usrData);
	printErrors("pxcRegisterAcqEvent", rc, ENTER_ON);

	// start continuous measuring (method 2, step 2)
	rc = pxcMeasureContinuous(deviceIndex, buffrerFrames, frameTime);
	printErrors("pxcMeasureContinuous", rc, ENTER_ON);

	printf("waiting for callbacks...\n");
	getchar(); // waiting so that callbacks can come
	printf("pxcMeasureContinuousTest: user end\n");
}
/*The callback function is some as used in pxcMeasureMultipleFramesWithCallback example, but usrData structure contains
extra member, the cnt.This can be used to stop, whitch is additional in the callback: */

static unsigned cnt = 0;
cnt++;
if (usrData.cnt > 0 && cnt >= usrData.cnt) {
	// stop continuous measuring on user defined number of frames
	printf("pxcAbortMeasurement...");
	rc = pxcAbortMeasurement(usrData.di);
	printErrors("pxcAbortMeasurement", rc, ENTER_ON);
	printf("Press enter to exit the program.\n");
}


pxcAbortMeasurement


Stopts the currently running measurement on the indexed device.
Definition
PXCAPI int pxcAbortMeasurement(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Warning

Aborting measuremet from its callback (like as in commandline example in pxcMeasureContinuous) can cause lags for tens of seconds. If the pxcAbortMeasurement called by other way (Button event in GUI for example), abort is fast.


pxcGetMeasuredFrameCount


Returns number of measured frames in memory. Usesful with pxcMeasureMultipleFrames.
Definition
PXCAPI int pxcGetMeasuredFrameCount(unsigned deviceIndex);

Parameters

  • deviceIndex – index of the device, starting from zero
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcSaveMeasuredFrame


Saves the measured frame to a file on the harddrive. This can be used instead of the pxcGetMeasuredFrame.
Definition
PXCAPI int pxcSaveMeasuredFrame(unsigned deviceIndex, unsigned frameIndex, const char* filePath);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameIndex – index of the frame, starting from zero
  • filePath – path to the file where frame will be saved
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

void someCallback(intptr_t acqCount, intptr_t userData) { // ======================
	int rc; // return codes
	tMmfClbData usrData = *((tMmfClbData*)userData);
	rc = pxcSaveMeasuredFrame(usrData.di, (unsigned)acqCount - 1, "testFile.txt");
	printErrors("pxcSaveMeasuredFrame-txt", rc, ENTER_ON);
	rc = pxcSaveMeasuredFrame(usrData.di, (unsigned)acqCount - 1, "testFile.png");
	printErrors("pxcSaveMeasuredFrame-txt", rc, ENTER_ON);
	/* List of file extensions (format automatically detected by extension in filename):
	#define PX_EXT_ASCII_FRAME "txt"
	#define PX_EXT_BINARY_FRAME "pbf"
	#define PX_EXT_MULTI_FRAME "pmf"
	#define PX_EXT_BINARY_MULTI_FRAME "bmf"
	#define PX_EXT_COMP_TPXSTREAM "pcts"
	#define PX_EXT_TPX3_PIXELS "t3p"
	#define PX_EXT_TPX3_PIXELS_ASCII "t3pa"
	#define PX_EXT_TPX3_RAW_DATA "t3r"
	#define PX_EXT_FRAME_DESC "dsc"
	#define PX_EXT_INDEX "idx"
	#define PX_EXT_CLUSTER_LOG "clog"
	#define PX_EXT_PIXEL_LOG "plog"
	#define PX_EXT_PNG "png"
	#define PX_EXT_PIXET_RAW_DATA "prd"
    (t3.. formats not frames - cannot be used with pxcSaveMeasuredFrame) */
}


pxcGetMeasuredFrame


Gets data of specified measured frame from memory
Definition
PXCAPI int pxcGetMeasuredFrame(unsigned deviceIndex, unsigned fameIndex, unsigned short* frameData, unsigned* size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameIndex – index of the frame, starting from zero
  • frameData – pointer to buffer where data will be saved. For single chip detector size is 65536.
  • size – pointer to varible with the size of the buffer. The actual size will be output to this variable.
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

This function have only one framebuffer. This is fully sufficient for single-output devices and modes. In combined modes (ToA+ToT, Event+IToT, dual threshold) only first data are available (ToA, Event, Threshold0). To take both outputs from the combined modes, it is necessary to use specialized functions for the given type of detector.


pxcGetMeasuredFrameTpx2


Gets data of specified measured frame from memory.
For Timepix2 chip only and only if calibration disabled.
Definition
PXCAPI int pxcGetMeasuredFrameTpx2(unsigned deviceIndex, unsigned frameIndex, unsigned* frameData1, unsigned* frameData2, unsigned* size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameIndex – index of the frame, starting from zero
  • frameData1 – pointer to buffer where data from the first counter (based on set operationmode) will be saved. For single detector chip size is 65536
  • frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single chip detector size is 65536
  • size - pointer to varible with the size of the buffer. The actual size will be output to this variable
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
For Timepix2 chip only and only if calibration disabled.


pxcGetMeasuredCalibratedFrameTpx2


Gets data of specified measured frame with calibration from memory.
For Timepix2 chip only and only if calibration enabled.
Definition
PXCAPI int pxcGetMeasuredCalibratedFrameTpx2(unsigned deviceIndex, unsigned frameIndex, double* frameData1, unsigned* frameData2, unsigned* size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameIndex – index of the frame, starting from zero
  • frameData1 – pointer to buffer where calibrated ToT->Energy data from the first counter (based on set operationmode) will be saved. For single detector chip size is 65536
  • frameData2 – pointer to buffer where data from the second counter (based on set operation mode) will be saved. For single chip detector size is 65536
  • size - pointer to varible with the size of the buffer. The actual size will be output to this variable
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix2 devices, not usable on other Timepixes or Medipixes.
For Timepix2 chip only and only if calibration enabled.


pxcGetMeasuredFrameTpx3


Gets data of specified measured frame from memory. For Timepix3 chip only.
Definition
PXCAPI int pxcGetMeasuredFrameTpx3(unsigned deviceIndex, unsigned fameIndex, double* frameToaITot, unsigned short* frameToTEvent, unsigned* size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • frameIndex – index of the frame, starting from zero
  • frameToaITot – pointer to buffer where data from ToA or iToT counter (based on set operation mode) will be saved. For single chip detector, size is 65536
  • frameTotEvent – pointer to buffer where data from ToT or Event counter (based on set operation mode) will be saved. For single chip detector, size is 65536
  • size – pointer to varible with the size of the buffer. The actual size will be output to this variable
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Only for the Timepix3 devices, not usable on other Timepixes or Medipixes.


API data-driven measuring functions

Data-driven: Cluster example

The functions described in this chapter can be used if frame-based measurement is not good choice, in particle collision research, for example.

Data-driven "frameless" in comparsion with frames:

Advantages
It is possible to continual measure for any length of time and repeated pixel hits are not lost.
Disadvantages
Each pixel is transmitted as a separate packet, including its position. Therefore, this mode is significantly more demanding on the transmission speed.


Afther measurement start, data from every event is stored in the buffer. Pixels has structures (defined in the pxcapi.h):

typedef struct _Tpx3Pixel {
	double       toa;   // time of arrival [1 ns]
	float        tot;   // time over threshold [25 ns] or energy [keV] if calibrated
	unsigned int index; // index of pixel position
} Tpx3Pixel;

#pragma pack(push, 1)
typedef struct _RawTpx3Pixel {
    u32  index:      24;
    u64  toa:        64;
    byte overflow:   1;
    byte ftoa:       5;
    u16  tot:        10;
} RawTpx3Pixel;
#pragma pack(pop)

See: The RawTpx3Pixel structure in memory


The Pixet core has a circular buffer in memory. The default size is 100 MB. There are blocks in the buffer. The default block size is 66000 bytes. Incoming data is stored in a block. The “new data” event (that can start the callback or save the blockt to file) occurs if:

  • The data size reaches the block size
  • Some data is in block over the timeout (500 ms)
  • The measurement ends

If you need to process data more often, you can set smaller block size. But if blocks are too small, data transfer speed can fall and some data can be lost. This can occurs if block size is less than approximately 5000 bytes (depends on computer speed and other circumstances).

Example projects
MiniPixTpx3-DataDriven, commandline example – Set the parameters, use the callback and display the data, some auxiliary things and data convert. Save data to files. Without threads.
AdvacamAPIexamples/Tpx3, Windows GUI CLR app – All common functions including data-driven measurements. Using threads.
Note
Functions in this chapter is only for the Timepix3 devices, not usable on other Timepixes or Medipixes.

pxcMeasureTpx3DataDrivenMode

Performs a measurement with Timepix3 detector in Data Driven Mode (event by event mode, when stream of pixels is sent). Timepix3 only.
Definition
PXCAPI int pxcMeasureTpx3DataDrivenMode(unsigned deviceIndex, double measTime, const char* filename, unsigned trgStg, AcqEventFunc callback, intptr_t userData);

Parameters

  • deviceIndex – index of the device, starting from zero
  • measTime – the total time of the measurement in seconds. Use 0 for infinite.
  • filename – output file name and path (extensions must end *.t3pa, *.trp, *.t3r)
  • trgStg – settings of external trigger - one of the PXC_TRG_XXX values. Default PXC_TRG_NO
  • callback – pointer to function of acqEventFunc type
  • userData – pointer to some user object/memory that is passed in callback function
See pxcRegisterAcqEvent for userData details
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

int rc = pxcMeasureTpx3DataDrivenMode(0, 15, "testfile.t3pa");
// Measure for 15 seconds on device 0 with saving to the "testfile.t3pa" file


Example for online processing
void timepix3DataDrivenGetPixelsTest(unsigned deviceIndex) { // ============================
	int rc; // return codes
	double measTime = 30;
	int devIdx = deviceIndex; // transmitted over pointer for use in the callback function

	// working with TOA, TOATOT, TOT_NOTOA, not working with EVENT_ITOT
	rc = pxcSetTimepix3Mode(deviceIndex, PXC_TPX3_OPM_TOA);
	printErrors("pxcSetTimepix3Mode", rc, ENTER_ON);

	rc = pxcSetDeviceParameter(deviceIndex, PAR_DD_BLOCK_SIZE, 6000); // block [B]
	printErrors("pxcSetDeviceParameter", rc, ENTER_OFF);
	rc = pxcSetDeviceParameter(deviceIndex, PAR_DD_BUFF_SIZE, 100); // buffer [MB]
	printf(", %d", rc);
	rc = pxcSetDeviceParameter(deviceIndex, PAR_DCC_LEVEL, 80);
	printErrors(",", rc, ENTER_ON); // data consistency check level (50-150) (*)

	rc = pxcMeasureTpx3DataDrivenMode(deviceIndex, measTime, "", PXC_TRG_NO, onTpx3Data, (intptr_t)&devIdx);
	printErrors("pxcMeasureTpx3DataDrivenMode", rc, ENTER_ON);
}

// * Data consistency check level : Detection level of ToA data inconsistency.
// If the chip is overloaded due too many partickes in time, clock can freezeand a ToA inconsistency occurrs.
// If it is detedted, measuring immediately stopand error “Acquisition failed(Data flow corrupted !!)“ occurrs.
// Level 50 is some like OFF, level 150 is highest sensitivity.

void onTpx3Data(intptr_t eventData, intptr_t userData) { // ================================
	int deviceIndex = *((unsigned*)userData);
	unsigned pixelCount = 0;
	int rc; // return codes

	rc = pxcGetMeasuredTpx3PixelsCount(deviceIndex, &pixelCount);
	printErrors("getMeasuredTpx3PixelsCount", rc, ENTER_OFF);
	printf(" PixelCount: %u\n", pixelCount);

	auto result = new Tpx3Pixel[pixelCount];
	rc = pxcGetMeasuredTpx3Pixels(deviceIndex, result, pixelCount);
	printErrors("pxcGetMeasuredTpx3Pixels", rc, ENTER_ON);

	dataUsingFunction(&result, pixelCount);
	delete[] result;
}

pxcGetMeasuredTpx3PixelsCount

Gets the number of measured Timepix3 pixels in data driven mode. Timepix3 only.
Definition
PXCAPI int pxcGetMeasuredTpx3PixelsCount(unsigned deviceIndex, unsigned*  pixelCount);

Parameters

  • deviceIndex – index of the device, starting from zero
  • pixelCount – pointer to output variable for number of pixels
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Example

unsigned int cnt;
int rc = pxcGetMeasuredTpx3PixelsCount(0, &cnt);
if (rc==0) printf("%d pixels from device idx 0 are waiting in memory\n", cnt);
else printf("pxcGetMeasuredTpx3PixelsCount failed, code %d\n", rc);


pxcGetMeasuredTpx3Pixels

Gets the measured Timepix3 pixels data. Timepix3 only.
Definition
PXCAPI int pxcGetMeasuredTpx3Pixels(unsigned deviceIndex, Tpx3Pixel* pixels, unsigned pixelCount);

Parameters

  • deviceIndex – index of the device, starting from zero
  • pixels – pointer to array of Tpx3Pixels that will be filled with measured pixels
ToT in output data are ToT in 25ns ticks or energy in keVs, depending on Timepix3CalibrationEnabled
See pxcSetTimepix3CalibrationEnabled, pxcIsTimepix3CalibrationEnabled
  • pixelCount – size of the supplied array as number of pixels
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcGetMeasuredRawTpx3Pixels

Gets the measured Timepix3 pixels data in raw format. Timepix3 only.
Definition
PXCAPI int pxcGetMeasuredRawTpx3Pixels(unsigned deviceIndex, RawTpx3Pixel* pixels, unsigned pixelCount);

Parameters

  • deviceIndex – index of the device, starting from zero
  • pixels – buffer where pixels will be saved
  • pixelCount – size of pixels buffer (number of pixels to save)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.

Note

Use the pxcGetMeasuredRawTpx3Pixels only in special, exceptional cases.

Warning

See: The RawTpx3Pixel structure in memory


pxcCalibrateTpx3PixelsAndFilter

Calibrate the pixel data and filter them by energy range
Definition
PXCAPI int pxcCalibrateTpx3PixelsAndFilter(unsigned deviceIndex, Tpx3Pixel* pixels, unsigned* pixelCount, double minEnergy, double maxEnergy);

Parameters

  • deviceIndex – index of the device, starting from zero
  • pixels – pointer to array of Tpx3Pixels that will be filled with measured pixels
  • pixelCount – size of pixels buffer (number of pixels). It will be filled with the number of pixel remaining after filtration
  • minEnergy – minimal allowed energy of each pixel
  • maxEnergy – maximal allowed energy of each pixel
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


API frame-data processing functions

Left: raw image, mid: After beam hardening correction, right: after BHC and bad pixels interpolation
Left: raw image, mid: After beam hardening correction, right: after BHC and bad pixels interpolation

Interpolating of bad pixels


pxcInterpolateBadPixels


Interpolates bad pixels in the image. Uses badPixelsMatrix as bad pixels (badPixel = 1, good = 0)
Definition
PXCAPI int pxcInterpolateBadPixels(unsigned char* badPixelsMatrix, double* data, unsigned width, unsigned height);

Parameters

  • badPixelMatrix – matrix of the bad pixels
  • data – data to be interpolated
  • width – width of the image
  • height – height of the image
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcGetDeviceBadPixelMatrix


Gets the devices's matrix of bad pixels (bad = 1, good = 0). Bad pixels are pixels that are masked.
Definition
PXCAPI int pxcGetDeviceBadPixelMatrix(unsigned deviceIndex, unsigned* badPixelMatrix, unsigned size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • badPixelMatrix – output data buffer where bad pixel matrix will be saved
  • size – size of the data - number of pixels (width * height)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


Beam hardening correction

The functions described in this chapter can be used to compensate the beam hardening effect, bad pixels and chip sensitivity uneven to get the data with true thickness of measured material.

First step is adding set of the reference images (masks). Dirrect beam (or beam with filter that will be used in all the process) and flat plates with different thicknesses, optimally in whole range that you want measuring. Use the pxcAddBHMask. Reference images contains unsigned 32bit pixels. To create the reference pictures, recommended fold more acquired images to achieve pixel values aproximatelly tens of thousands or more (50,000 is good start). Don’t forget corectly set their thickness.

If 2 or more reference images have been added, it is possible to determine which pixels are not usable. Check this using the pxcGetBHBadPixelMatrix function. If there are too many of these pixels, the pxcApplyBHCorrection function may lose accuracy and the pxcInterpolateBadPixels function will not work. In this case you can check:

  • If the set-up is correct (condition of the reference plates; Is the whole area of the chip good irradiated and covered by the reference plates? Is there an obstacle in the beam?)
  • If there is too much contrast between the references - a common problem, especially between the free beam and the first reference plate - you can use a filter throughout the process
  • If some areas have too low values with high noise - increase the number of integrated frames, beam intensity, or acquisition time
  • If exist areas with overexposition – decrease the time or beam intensity
  • If the instability of the CdTe chip has manifested itself - increase the time by integrating the reference images
  • If using CdTe and measuring start too soon afther chip init
  • Try use other beam energy

After add sufficient number of reference images, you can measure image of the sample and use the pxcApplyBHCorrection function. Output is array of double, in units from reference thicknesses.

Now you can use the pxcGetDeviceAndBHBadPixelMatrix to get array of bad and other unusable pixels. Use this data with the pxcInterpolateBadPixels. If it doesn't work, you can use only device bad pixels from the pxcGetDeviceBadPixelMatrix function.

Example projects
MiniPixTpx3-Thickness-auto – Acquision time auto tuning for easy first experiments.
Interactive control in console, text histograms and preview of images. But the code is relatively complex.
MiniPixTpx3-Thickness-bath – Bath process, using text config file.
Simple code, but you need to set usable acquisition times.

pxcAddBHMask


Adds a new mask (frame) for Beam-Hardening calibration.
Definition
PXCAPI int pxcAddBHMask(unsigned* data, unsigned size, double frameTime, double thickness);

Parameters

  • data – data of the frame tat will be used as BH mask
  • size – size of the data - number of pixels (width * height)
  • frameTime – acquisition time of the frame in seconds
  • thickness – thickness of the measured data
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcBHMaskCount


Returns number of inserted Beam-Hardening masks (frames)
Definition
PXCAPI int pxcBHMaskCount();

Parameters

(no pars)
Return value
Number of masks if successful, otherwise the return value is a PXCERR_XXX code


pxcRemoveBHMask


Removes Beam-Hardening mask (frame)
Definition
PXCAPI int pxcRemoveBHMask(int index);

Parameters

  • index – index of the mask to remove
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcApplyBHCorrection


Applies the Beam-Hardening correction to supplied frame
Definition
PXCAPI int pxcApplyBHCorrection(unsigned* inData, unsigned size, double frameTime, double* outData);

Parameters

  • inData – data of the frame that will be corrected
  • size – size of the data - number of pixels (width * height)
  • frameTime – acquisition time of the measured frame in seconds
  • outData – output data buffer where corrected data will be saved
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcGetBHBadPixelMatrix


Gets the bad pixel matrix from Beam Hardening correction - pixels that cannot be corrected. (bad pixel = 1, good = 0). Must be called after all BH masks are added.
Definition
PXCAPI int pxcGetBHBadPixelMatrix(unsigned* badPixelMatrix, unsigned size);

Parameters

  • badPixelMatrix – output data buffer where bad pixel matrix will be saved
  • size – size of the data - number of pixels (width * height)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


pxcGetDeviceAndBHBadPixelMatrix


Gets the combined bad pixel matrix from the device and BeamHardening (badpixel = 1, good = 0).
Definition
PXCAPI int pxcGetDeviceAndBHBadPixelMatrix(unsigned devIndex, unsigned* badPixelMatrix, unsigned size);

Parameters

  • deviceIndex – index of the device, starting from zero
  • badPixelMatrix – output data buffer where bad pixel matrix will be saved
  • size – size of the data - number of pixels (width * height)
Return value
0 if successful, otherwise the return value is a PXCERR_XXX code.


See: pxcGetDeviceBadPixelMatrix, pxcInterpolateBadPixels


Example


See:



Some images


CdTe vs Si
1. CdTe 2 mm (left) vs Si 0,3 mm (right)


CdTe advantages: More sensitive, orders of magnitude shorter acquisition times or lower beam intensities. Have lower energy consumption and and it less warming.
imgs:
CdTe: integrated 3.43 sec (25,6 ms subframes)
Si: integrated 27.7 sec (625 ms subframes)


CdTe artefacts
CdTe disadvantages: Uneven distribution of chip sensitivity. Slow instability can cause the need for a long total measurement time.

Specialy thick chips have a easily visible image distortion. Afther start-up, CdTe contains lot of free charges, they can cause problems duringearly measurements (use pxcDoSensorRefresh).

Si and CdTe have opposite bilas polarity. This can be used for type detection.


beam hardening experimental setup
beam hardening experimental setup
2. The beam hardening experimental setup

1 – The sensor
2 – Pb shielding of electronics (for sure, large intensities were tested in this experiment)
3 – several thin sheets, a total of 0.3 mm to reduce free beam / first ref. plate contrast
4 – 0.6 mm reference plates


Beam hardening Bh1c.png
Beam hardening Bh2c.png
3. Test images

Left is Fe bearing, used reference plates and the setup from img. 2

Right is Al plates, 3 and 8 mm, reference plates was several 3mm sheets

Up – original images
Mid – afther pxcApplyBHCorrection
Down – mid afther pxcInterpolateBadPixels
(range in all images auto-resized to grayscale 0-255)


Beam hardening Bh2a.jpg
4. The Al plates experimental setup


1 – Cooler - Si chip used
2 – The Minipix
3 – Imaged aluminium plates
4 – Thin Al sheet to reduce free beam / first ref. plate contrast

The synchronizing

The synchronizing-Widepix.jpg
Sometimes it is necessary to synchronized with an external event. Or some instruments, Widepix-L for example, can be organized as set of more than 1 device in 1 box and more than 1 data cable go out. If you want start acquisition on whole instrument at exactly the same time, must use synchronization by the hardware trigger.

Synchronizing basics

The acquisition functions have the TrgStg parameter. The 4th argument "trigger settings" of the pxcMeasureTpx3DataDrivenMode(), for example. This have options:

PXC_TRG_NO No sync. Normally start immediatelly and stop after acqTime.
PXC_TRG_HWSTART Slave wait and start the acq. on HW signal, master can wait for slave ready.
PXC_TRG_HWSTOP
 
Start the acq. immediatelly and stop on HW signal or after acqTime.
(Available only in specific devices, see sync. manual.)
PXC_TRG_HWSTARTSTOP
 
Wait and start the acq. on HW signal and stop at next HW signal.
(Available only in specific devices, see sync. manual.)
PXC_TRG_SWSTART Wait and start the acq. on SW signal = pxcDoSoftwareTrigger().


Additionally, you must use the named parameters. You can read if the device is ready, is it master, etc and write some parameters. Details depends on the device type. Some devices allow reset the ToA counter without restart acquisition or start acquisition without reset the ToA counter.

See: Parameter Get/Set functions (using text paramName)

Synchronizing with an external source

Sync with the external source can depends on the device type. See the synchronization manual of your device type for hardware details.

Example: Way to use the external HW sync with the Advapix-Tpx3

1. Set some synchronization parameters: "TrgTimestamp", "TrgT0SyncReset", "TrgOutLevel", "TrgOutEnable" using function to write the named parameters: pxcSetDeviceParameter.
2. Read some synchronization parameters: "TrgReady", "IsMaster" using the pxcGetDeviceParameter.
3. Start the pxcMeasure... with some PXC_TRG_HW...
4. Apply the sync signal to the input.

Synchronizing in multi-device instruments

(This text is primary about the WIdepix-L with 2 ethernet cables, if using other device, see the Synchronization manual of your device)

Decision which device is master

    isMaster = pxcGetDeviceParameter(devIdx, "TriggerMaster");

Output is 0 for slave, 1 for master or single, <0 if the device not supports param name/type.

Note
Some devices has IsMaster and some other has TriggerMaster.
Some devices has output bool (read as int 0/1) and some other has string (read as char[] "Yes"/"No")
In universal software, expect all 4 combinations to exist.


Master Setup

  1. Set the parameter TriggerStg = 0
  2. Set the parameter TriggerWaitForReady = 1
  3. Set the parameter TriggerOutLevel = 1

Slave setup

  1. Set the parameter TriggerStg = 2
  2. Set the parameter TriggerWaitForReady = 1

The measurement
This can be simple if the continuous acquisition is used: This API function starts in separate thread:

rcs = pxcMeasureContinuous(slvIdx, bufCnt, acqTime, PXC_TRG_HWSTART, callback, (intptr_t)slvIdx);
rcm = pxcMeasureContinuous(masIdx, bufCnt, acqTime, PXC_TRG_HWSTART, callback, (intptr_t)masIdx);
errorToList("pxcMeasureContinuous s,m", rcs, rcm);

But if using other acq. functions, you must start slave acq. in separate thread manually.
(see the Visual Studio example “Mpx3-2-sync”)

Note Widepix-L

If the acquisition time is long, approximately from 100 ms, the run is irregular and there may be long pauses (1 to 5 * acqTime) between acquisitions. This can be suppressed if master acqTime is approximately over 10 % longer.

Widepix-L: The TriggerStg and TriggerOutLevel are linked in the following way:

Function Master TriggerStg Master TriggerOutLevel Slave TriggerStg Slave TriggerOutLevel
Sync 1:1 0 0 3 X
Alternating sync 0 0 2 X
Alternating sync 0 1 3 X
Sync 1:1 0 1 2 X

X - the value doesn't matter

Synchronizing a multi-device with an external source

Set the device normally for synchronizing in multi-device (See chapter above for details), but in the master settings set the TriggerStg alias TrgStg to 2 or 3 by the used edge of trigger signal. Be carefull if using 0 or 1.

Example setting for double-device external sync on rising edge
Function Master TriggerStg Master TriggerOutLevel Slave TriggerStg Slave TriggerOutLevel
Ext and 1:1 2 1 2 X

X - the value doesn't matter

Multi-device synchronizing examples

These samples are derived from the Mpx3 project from the AdvacamAPIexamples collection.

Global variables of the example:

unsigned	*collectDevFrameD1 = NULL, *collectDevFrameD2 = NULL; // collected devs all frame data
unsigned	collectDevFramePxCnt = 0;	// collectDevFrameDx size = devWid * devHei * devCnt * collectImgCnt
unsigned	devcollectDevsIdx[256];		// list of devs to collect imgs
int			collectDevsCnt = -1;		// count of devs to be collected (>0 to enable)
int			collectDevsMasterIdx = -1;	// index of master position in devcollectDevsIdx[]
unsigned	collectDevWidth = -1, collectDevHeight = -1; // size of collected image
unsigned	collectImgsMax = 0; // =textColImgsMax->Text; vertical count of images to be collected
int			collectDevCntCallbacks, collectDevCntOK, collectDevCntFail; // callbacks img collect status

double		acqTime = 1.0;		// time for acq. functions
int			frameCount = 0;		// frames count for pxcMeasureMultipleFrames
								// or cilcular buffer frames count for pxcMeasureContinuous
int deviceMaxIdx = -1;			// maximal connected dev idx (count-1)
int deviceIndex = -1;			// index of the single device to be used
int frameLastIndex = -1;		// index of the frame that was viewed and for saving

Preparing setup for synchronized Mpx3 multi-device example

Decision if the dev is master (all dev types with internal synchronization):

int isDevMaster(unsigned di) {
	int rc = pxcGetDeviceParameter(di, "TriggerMaster");
	if (rc == 0 || rc == 1) return rc;

	rc = pxcGetDeviceParameter(di, "IsMaster");
	if (rc == 0 || rc == 1) return rc;

	char val[] = "   ";
	rc = pxcGetDeviceParameterString(di, "TriggerMaster", val, 4);
	if (rc!=0) pxcGetDeviceParameterString(di, "IsMaster", val, 4);
	if (rc == 0) {
		if (strcmp(val, "Yes") == 0) return 1;
		else if (strcmp(val, "No") == 0) return 0;
		else return MY_ERR_CODE;
	}
	return rc;
}


Setup devices, the textCollectDevsOrd contains device indexes order string, like as "102", primary used to joining images side by side in the desired order (Tested with Widepix, ethernet or USB):

collectDevsCnt = textCollectDevsOrd->Text->Length;
int trgMastCnt = 0;
for (int n = 0; n < collectDevsCnt; n++) {
	devcollectDevsIdx[n] = Convert::ToInt32(textCollectDevsOrd->Text[n] - '0');
	if (devcollectDevsIdx[n] > deviceMaxIdx) { // deviceMaxIdx = global, set after init pxcore
		collectDevsCnt = -1;
		msgToList(String::Format("Collect devs: devIdx out of range {0}", devcollectDevsIdx[n]));
	}

	int isMast = isDevMaster(devcollectDevsIdx[n]);
	if (isMast < 0) {
		errorToList("pxcGetDeviceParameter TriggerMaster", isMast);
		isMast = 0;
	}
	if (isMast == 1) {
		trgMastCnt++;
		collectDevsMasterIdx = n;
		rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerStg", 0);
		errorToList("pxcSetDeviceParameter TriggerStg", rc);
		rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerWaitForReady", 1);
		errorToList("pxcSetDeviceParameter TriggerWaitForReady", rc);
		rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerOutLevel", 1);
		errorToList("pxcSetDeviceParameter TriggerOutLevel", rc);
	} else {
		rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerStg", 2);
		errorToList("pxcSetDeviceParameter TriggerStg", rc);
		rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerWaitForReady", 1);
		errorToList("pxcSetDeviceParameter TriggerWaitForReady", rc);
		rc = pxcSetDeviceParameter(devcollectDevsIdx[n], "TriggerOutLevel", 0);
		errorToList("pxcSetDeviceParameter TriggerOutLevel", rc);
	}
}
if (trgMastCnt != 1 || collectDevsCnt < 2) {
	msgToList("Err: 2 or more devs incl. 1 TriggerMaster needed for collect");
	collectDevsCnt = -1;
	collectDevsMasterIdx = -1;
} else {
	msgToList(String::Format("Collect devs setup complete. Master idx/devIdx:{0}/{1}",
		collectDevsMasterIdx, devcollectDevsIdx[collectDevsMasterIdx]));
}

Starting acquisitions for synchronized Mpx3 multi-device example

This section using the callbacks to get actual data. The userData parameter is used to inform the callback function about source device index in the devcollectDevsIdx[]. Based on the index into devcollectDevsIdx[] and the frame index, a place in the buffer is selected and read from the device is called.

Setup and start the synchronized measurement with using continuous acquisition.
Note: Continuous mode is not usable with TDI.
(Tested with Widepix, ethernet or USB):

rc = initMeasParams("Continuous acq. with callback test", true, true); // set-up buffers, operation mode and other measurement settings
if (rc!=0) return;

if (collectDevsCnt > 0) {
	for (int n = 0; n <= collectDevsCnt; n++) {
		if (n == collectDevsMasterIdx) continue; // skip the master and start it at end
		int di = devcollectDevsIdx[n];
		if (n == collectDevsCnt) di = devcollectDevsIdx[collectDevsMasterIdx];

		rc = pxcMeasureContinuous(di, frameCount, acqTime, PXC_TRG_HWSTART, clbContinuousAcq,
			(n < collectDevsCnt) ? n : collectDevsMasterIdx);
		msgToList(String::Format("n:{0} di:{1} pxcMeasureContinuous {2} {3}",
			n, di, rc, (rc==0)? "OK": "failed"));
		if (rc != 0) return;
	}
} else {
	// pxcMeasureContinuous(unsigned deviceIndex, unsigned frameBufferSize, double frameTime, unsigned trgStg = PXC_TRG_NO, FrameMeasuredCallback callback = 0, intptr_t userData = 0);
	rc = pxcMeasureContinuous(deviceIndex, frameCount, acqTime, PXC_TRG_NO, clbContinuousAcq, NULL);
	errorToList("pxcMeasureContinuous", rc);
}


Setup and start the synchronized measurement with using multi-acquisition.
A bit more complicated, but works with TDI as well.
(Tested with Widepix, ethernet or USB):

int rc;
DWORD dwThrID;
HANDLE h;

int rc = initMeasParams("More frames with callback test", true, true); // set-up buffers, operation mode and other measurement settings
if (rc!=0) return;
if (collectDevsCnt>0) {
	for (int n = 0; n <= collectDevsCnt; n++) {
		if (n == collectDevsMasterIdx) continue; // skip master and start it at end
		int di = devcollectDevsIdx[n];
		if (n == collectDevsCnt) di = devcollectDevsIdx[collectDevsMasterIdx];
		sMeasureMultFrsCallbackPars* thrData = new sMeasureMultFrsCallbackPars(di, frameCount, acqTime, PXC_TRG_HWSTART, clbFramesWC,
			(n < collectDevsCnt) ? n : collectDevsMasterIdx);
		h = CreateThread(NULL, 0, MeasureMultFrsCallbackThrFn, (void*)thrData, 0, &dwThrID);
		msgToList(String::Format("n:{0} di:{1} CreateThread {2} OK", n, di, (int)dwThrID));
		if (h == NULL) {
			msgToList(String::Format("n:{0} di:{1} CreateThread {2} failed", n, di, (int)dwThrID));
			return;
		}
	}
} else {
	sMeasureMultFrsCallbackPars* thrData = new sMeasureMultFrsCallbackPars(deviceIndex, frameCount, acqTime, PXC_TRG_NO, clbFramesWC, NULL);
	h = CreateThread(NULL, 0, MeasureMultFrsCallbackThrFn, (void*)thrData, 0, &dwThrID);
	msgToList("pxcMeasureMultipleFramesWithCallback - thread " + System::Convert::ToString((int)dwThrID));
	if (h == NULL) return;
}

Callbacks for synchronized Mpx3 multi-device example

Collecting the image data, called from callbacks (Tested with Widepix, ethernet or USB):

// idx of devcollectDevsIdx, frame idx
void collectDevImgs(unsigned ndi, unsigned fIdx) {
	int rc;
	
	size_t		adrAdd = static_cast<size_t>(devPixels * (ndi + (fIdx % collectImgsMax) * collectDevsCnt));
	unsigned	*cd1 = collectDevFrameD1 + adrAdd;
	unsigned	*cd2 = collectDevFrameD2 + adrAdd;
	unsigned	bs = collectDevFramePxCnt - adrAdd;

	if (bs < 0x80000000) {
		rc = pxcGetMeasuredFrameMpx3(devcollectDevsIdx[ndi], fIdx, cd1, cd2, &bs);
	} else rc = MY_ERROR_CODE;

	collectDevCntCallbacks++;
	if (rc == 0) {
		collectDevCntOK++;
	} else {
		collectDevCntFail++;
	}
}


The callbacks:

// callback function for "frames with callback"
void clbFramesWC(intptr_t acqCount, intptr_t userData) {
	frameLastIndex = acqCount-1;
	clbCnt++;
	if (collectDevsCnt > 0) {
		collectDevImgs((unsigned)userData, frameLastIndex);
		return;
	}
}

// callback function for continuous acquisition
void clbContinuousAcq(intptr_t acqCount, intptr_t userData) {
	if (acqCount<0) {
		clbError = acqCount;
		return;
	}
	frameLastDevIdx = (int)userData;
	clbCnt++;

	if (acqCount<frameCount) {
		frameLastIndex = acqCount - 1;
	} else {
		if (++frameLastIndex>=acqCount) frameLastIndex = 0;
	}

	if (collectDevsCnt > 0) {
		collectDevImgs((unsigned)userData, frameLastIndex);
		return;
	}
}


Rearranging measured data to complete image

When all measurements are complete, the data is arranged in memory so that each frame from each device occupies a contiguous area. In order for images to be connected when displaying, each line of the resulting image must contain lines from individual neighboring devices.

Rearranging data from two adjacent sub-devices and three images
Measured data in memory Rearranged data in memory
device 0 / frame 0 device 0 / frame 0 device 1 / frame 0
device 1 / frame 0
device 0 / frame 1 device 0 / frame 1 device 1 / frame 1
device 1 / frame 1
device 0 / frame 2 device 0 / frame 2 device 1 / frame 2
device 1 / frame 2
compiledFr1 = (unsigned*)malloc(collectDevFramePxCnt * sizeof(unsigned));
//compiledFr2 = (unsigned*)malloc(collectDevFramePxCnt * sizeof(unsigned));

compiledImgData1 = (int*)malloc(collectDevFramePxCnt * sizeof(int));
//compiledImgData2 = (int*)malloc(collectDevFramePxCnt * sizeof(int));

if (!compiledFr1 || !compiledImgData1) {
	msgToList("viewCollectedDevsFrs: Memory allocation failed");

	if (compiledFr1) free(compiledFr1);
	if (compiledFr2) free(compiledFr2);
	if (compiledImgData1) free(compiledImgData1);
	if (compiledImgData2) free(compiledImgData2);
	return;
}

size_t adrAddIn = 0, adrAddOut = 0;
// adrAdd = devPixels * ndi   +   collectDevsCnt * devPixels * (fIdx % collectImgsMax);
for (size_t fi = 0; fi < collectImgsMax; fi++) {			// frames
	for (size_t lin = 0; lin < collectDevHeight; lin++) {	// lines of single frame
		for (size_t ndi = 0; ndi < collectDevsCnt; ndi++) {	// subdevices idxs in collectDevsCnt
			adrAddIn = collectDevsCnt * devPixels * fi + devPixels * ndi + devWidth * lin;

			if (checkCollectReverseLines->Checked) {
				for (size_t x = 0; x < devWidth; x++) {
					(compiledFr1 + adrAddOut)[x] = (collectDevFrameD1 + adrAddIn)[devWidth - x];
					//(compiledFr2 + adrAddOut)[x] = (collectDevFrameD2 + adrAddIn)[devWidth - x];
				}
			} else {
				memcpy(compiledFr1 + adrAddOut, collectDevFrameD1 + adrAddIn, devWidth * sizeof(unsigned));
				//memcpy(compiledFr2 + adrAddOut, collectDevFrameD2 + adrAddIn, devWidth * sizeof(unsigned));
			}
			adrAddOut += (size_t)devWidth;
		}
	}
}

colorizeData(compiledFr1, compiledImgData1, collectDevFramePxCnt);
Bitmap^ bmp1c = gcnew Bitmap(collectDevWidth, collectDevHeight * collectImgsMax, collectDevWidth * 4, System::Drawing::Imaging::PixelFormat::Format32bppRgb, (IntPtr)compiledImgData1);
pictureBox3->SizeMode = PictureBoxSizeMode::StretchImage;
pictureBox3->Image = bmp1c;

Related